PET/SPECT Test Phantom
It is vital to test the response, reliability and to determine image artifacts produced by the nuclear medicine tomography systems due to some systemic limitations before their use in clinical studies. That cannot be reliably achieved by scanning patients. Different types of test phantoms are commer...
Saved in:
Main Author: | |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2010
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/6054/1/IRIIE_2010_Poster.pdf http://irep.iium.edu.my/6054/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Islam Antarabangsa Malaysia |
Language: | English |
id |
my.iium.irep.6054 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.60542011-11-21T21:22:10Z http://irep.iium.edu.my/6054/ PET/SPECT Test Phantom Shah, Sayed Inayatullah QC Physics It is vital to test the response, reliability and to determine image artifacts produced by the nuclear medicine tomography systems due to some systemic limitations before their use in clinical studies. That cannot be reliably achieved by scanning patients. Different types of test phantoms are commercially available with accurately/precisely known composition, which helps in acquiring prior knowledge about the capability and drawbacks of a nuclear medicine tomography system. A cold regions insert, that can be placed into a cylindrical tank of a commercially provided PET/SPECT phantom has been developed (for R A Carlson’s phantom - which consists, hot, cold and linearity inserts where the hot regions insert is comprised on a “V” shaped eight pairs of various sized holes with a cold background). The new produced cold regions insert, consists solid plastic rods, 5 cm long (each) with same diameters and exactly the same arrangement as hot region holes pairs insert of R A Carlson’s phantom. Both inserts have been attached with each other by aligning hot and cold regions for similar cross sectional views. The data acquired by this arrangement provides a simple way for measurement and comparison of the performance of a system i.e., image resolution in terms of position and size of hot and cold regions in the phantom, region(s) detectability. Also the accuracy of scatter, attenuation correction and image reconstruction techniques in nuclear medicine tomography may be tested. 2010 Conference or Workshop Item REM application/pdf en http://irep.iium.edu.my/6054/1/IRIIE_2010_Poster.pdf Shah, Sayed Inayatullah (2010) PET/SPECT Test Phantom. In: IIUM Research, Invention and Innovation Exhibition IRIIE 2010, 26 - 27 January 2010, Culture Activity Centre, IIUM, Gombak. (Unpublished) |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
QC Physics |
spellingShingle |
QC Physics Shah, Sayed Inayatullah PET/SPECT Test Phantom |
description |
It is vital to test the response, reliability and to determine image artifacts produced by the nuclear medicine tomography systems due to some systemic limitations before their use in clinical studies. That cannot be reliably achieved by scanning patients. Different types of test phantoms are commercially available with accurately/precisely known composition, which helps in acquiring prior knowledge about the capability and drawbacks of a nuclear medicine tomography system. A cold regions insert, that can be placed into a cylindrical tank of a commercially provided PET/SPECT phantom has been developed (for R A Carlson’s phantom - which consists, hot, cold and linearity inserts where the hot regions insert is comprised on a “V” shaped eight pairs of various sized holes with a cold background). The new produced cold regions insert, consists solid plastic rods, 5 cm long (each) with same diameters and exactly the same arrangement as hot region holes pairs insert of R A Carlson’s phantom. Both inserts have been attached with each other by aligning hot and cold regions for similar cross sectional views. The data acquired by this arrangement provides a simple way for measurement and comparison of the performance of a system i.e., image resolution in terms of position and size of hot and cold regions in the phantom, region(s) detectability. Also the accuracy of scatter, attenuation correction and image reconstruction techniques in nuclear medicine tomography may be tested.
|
format |
Conference or Workshop Item |
author |
Shah, Sayed Inayatullah |
author_facet |
Shah, Sayed Inayatullah |
author_sort |
Shah, Sayed Inayatullah |
title |
PET/SPECT Test Phantom
|
title_short |
PET/SPECT Test Phantom
|
title_full |
PET/SPECT Test Phantom
|
title_fullStr |
PET/SPECT Test Phantom
|
title_full_unstemmed |
PET/SPECT Test Phantom
|
title_sort |
pet/spect test phantom |
publishDate |
2010 |
url |
http://irep.iium.edu.my/6054/1/IRIIE_2010_Poster.pdf http://irep.iium.edu.my/6054/ |
_version_ |
1643605663284199424 |