Outcome of NEXGEN® fixed bearing and posterior stabilising total knee replacement

Introduction: Total knee arthroplasty (TKA) represents a major advance in the treatment of degenerative joint disease, providing excellent restoration of joint function and pain relief. This study aim to evaluate the survival analysis of the implant, the functional and knee scores outcome and to ide...

Full description

Saved in:
Bibliographic Details
Main Authors: Noor Rahin, Mohd. Shahidan, Siron @ Baharom, Khairul Nizam, Mor Japar Khan, Ed Simor Khan, Zulkifly, Ahmad Hafiz, Harris, Muhammed
Format: Article
Language:English
Published: Kulliyyah of Medicine, International Islamic University Malaysia 2016
Subjects:
Online Access:http://irep.iium.edu.my/64027/1/64027_Outcome%20of%20NEXGEN%C2%AE%20fixed%20bearing%20and%20posterior.pdf
http://irep.iium.edu.my/64027/
http://iiumedic.net/imjm/v1/download/Volume%2015%20Supplement/MRS2016-ABSTRACT-BOOK-80.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
id my.iium.irep.64027
record_format dspace
spelling my.iium.irep.64027 http://irep.iium.edu.my/64027/ Outcome of NEXGEN® fixed bearing and posterior stabilising total knee replacement Noor Rahin, Mohd. Shahidan Siron @ Baharom, Khairul Nizam Mor Japar Khan, Ed Simor Khan Zulkifly, Ahmad Hafiz Harris, Muhammed RD701 Orthopedics Introduction: Total knee arthroplasty (TKA) represents a major advance in the treatment of degenerative joint disease, providing excellent restoration of joint function and pain relief. This study aim to evaluate the survival analysis of the implant, the functional and knee scores outcome and to identify a complication following Nexgen fixed bearing and posterior stabilizing total knee replacement. Methods: The present study was conducted to retrospectively review the results of all primary TKA performed at Hospital Tengku Ampuan Afzan over a period of 15 years from 2000 to 2015. The study sample consisted of 160 TKA. Oxford knee score and SF 36 were used and statistical analysis of both knee scores and functional scores were compared using SPSS software. Survivorship analysis was compared using the Kaplan-Meier method. Endpoints of implant defined as revision with removal of implant and addition or exchange of prosthetic components. Results: Functional and knee score post operatively was excellent and good. Mean range of movement of knee during the study period were left 107.50 degrees and right 106.49 degrees. Mean femoral flexion angle is 92.38 degrees and mean tibial angle is 89.48 degrees. The outcome categories for the Oxford knee score have 101 patients showed excellent result, 41 patients good, and 18 patients fair. In this study mean total SF 36 score is 80.99. Conclusions: The outcome shows that total knee replacement is a reproducible surgery for which a trained surgeon will be able to produce excellent and good results. Kulliyyah of Medicine, International Islamic University Malaysia 2016-11-10 Article PeerReviewed application/pdf en http://irep.iium.edu.my/64027/1/64027_Outcome%20of%20NEXGEN%C2%AE%20fixed%20bearing%20and%20posterior.pdf Noor Rahin, Mohd. Shahidan and Siron @ Baharom, Khairul Nizam and Mor Japar Khan, Ed Simor Khan and Zulkifly, Ahmad Hafiz and Harris, Muhammed (2016) Outcome of NEXGEN® fixed bearing and posterior stabilising total knee replacement. The International Medical Journal Malaysia, 15 (Supp. 1). p. 80. ISSN 1823-4631 http://iiumedic.net/imjm/v1/download/Volume%2015%20Supplement/MRS2016-ABSTRACT-BOOK-80.pdf
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic RD701 Orthopedics
spellingShingle RD701 Orthopedics
Noor Rahin, Mohd. Shahidan
Siron @ Baharom, Khairul Nizam
Mor Japar Khan, Ed Simor Khan
Zulkifly, Ahmad Hafiz
Harris, Muhammed
Outcome of NEXGEN® fixed bearing and posterior stabilising total knee replacement
description Introduction: Total knee arthroplasty (TKA) represents a major advance in the treatment of degenerative joint disease, providing excellent restoration of joint function and pain relief. This study aim to evaluate the survival analysis of the implant, the functional and knee scores outcome and to identify a complication following Nexgen fixed bearing and posterior stabilizing total knee replacement. Methods: The present study was conducted to retrospectively review the results of all primary TKA performed at Hospital Tengku Ampuan Afzan over a period of 15 years from 2000 to 2015. The study sample consisted of 160 TKA. Oxford knee score and SF 36 were used and statistical analysis of both knee scores and functional scores were compared using SPSS software. Survivorship analysis was compared using the Kaplan-Meier method. Endpoints of implant defined as revision with removal of implant and addition or exchange of prosthetic components. Results: Functional and knee score post operatively was excellent and good. Mean range of movement of knee during the study period were left 107.50 degrees and right 106.49 degrees. Mean femoral flexion angle is 92.38 degrees and mean tibial angle is 89.48 degrees. The outcome categories for the Oxford knee score have 101 patients showed excellent result, 41 patients good, and 18 patients fair. In this study mean total SF 36 score is 80.99. Conclusions: The outcome shows that total knee replacement is a reproducible surgery for which a trained surgeon will be able to produce excellent and good results.
format Article
author Noor Rahin, Mohd. Shahidan
Siron @ Baharom, Khairul Nizam
Mor Japar Khan, Ed Simor Khan
Zulkifly, Ahmad Hafiz
Harris, Muhammed
author_facet Noor Rahin, Mohd. Shahidan
Siron @ Baharom, Khairul Nizam
Mor Japar Khan, Ed Simor Khan
Zulkifly, Ahmad Hafiz
Harris, Muhammed
author_sort Noor Rahin, Mohd. Shahidan
title Outcome of NEXGEN® fixed bearing and posterior stabilising total knee replacement
title_short Outcome of NEXGEN® fixed bearing and posterior stabilising total knee replacement
title_full Outcome of NEXGEN® fixed bearing and posterior stabilising total knee replacement
title_fullStr Outcome of NEXGEN® fixed bearing and posterior stabilising total knee replacement
title_full_unstemmed Outcome of NEXGEN® fixed bearing and posterior stabilising total knee replacement
title_sort outcome of nexgen® fixed bearing and posterior stabilising total knee replacement
publisher Kulliyyah of Medicine, International Islamic University Malaysia
publishDate 2016
url http://irep.iium.edu.my/64027/1/64027_Outcome%20of%20NEXGEN%C2%AE%20fixed%20bearing%20and%20posterior.pdf
http://irep.iium.edu.my/64027/
http://iiumedic.net/imjm/v1/download/Volume%2015%20Supplement/MRS2016-ABSTRACT-BOOK-80.pdf
_version_ 1643617165140557824