Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution IV design

The present study aimed at the screening of parameters for electrocoagulation treatment of treated palm oil mill efuent using minimum-runs resolution IV design. The responses examined include: chemical oxygen demand removal (%), total suspended solids removal (%) and turbidity reduction (%), and the...

Full description

Saved in:
Bibliographic Details
Main Authors: Mujeli, Mustapha, Hussain, S. A., Ismail, M. H. S., Awang Biak, Dayang Radiah, Jami, Mohammed Saedi
Format: Article
Language:English
English
English
Published: Springer Berlin Heidelberg 2019
Subjects:
Online Access:http://irep.iium.edu.my/64050/21/64050_Screening%20of%20electrocoagulation%20process.pdf
http://irep.iium.edu.my/64050/19/64050_Screening%20of%20electrocoagulation%20process_SCOPUS.pdf
http://irep.iium.edu.my/64050/20/64050_Screening%20of%20electrocoagulation%20process_WOS.pdf
http://irep.iium.edu.my/64050/
https://link.springer.com/article/10.1007/s13762-018-1708-9
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
English
English
id my.iium.irep.64050
record_format dspace
spelling my.iium.irep.640502019-03-08T08:39:00Z http://irep.iium.edu.my/64050/ Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution IV design Mujeli, Mustapha Hussain, S. A. Ismail, M. H. S. Awang Biak, Dayang Radiah Jami, Mohammed Saedi TP155 Chemical engineering The present study aimed at the screening of parameters for electrocoagulation treatment of treated palm oil mill efuent using minimum-runs resolution IV design. The responses examined include: chemical oxygen demand removal (%), total suspended solids removal (%) and turbidity reduction (%), and the varied dependent factors comprise: electrical current density (mA/cm2), time (min), pH, electrolyte concentration (g/L), stirring speed (rpm), electrode spacing (mm) and electrode confguration (monopolar or dipolar). The statistical results revealed that the current density has a signifcant infuence on the treatment performance at two-level interactions with pH, electrode spacing and electrode concentration and at three-level correlations with time and pH. Thus, the most important factors afecting the removal efciency of the organic compounds were found to be pH, time, electrode spacing, electrolyte concentration and electrode confguration at a P value less than 0.05, respectively, in the descending order of signifcance. Therefore, the optimized electrocoagulation process could be reached with current density equal to 5 mA/cm2, electrolysis time of 5 min, electrode spacing of 5 mm and using monopolar electrode confguration. This combination provided the maximum ability of the process for chemical oxygen demand (68.84%), total suspended solids (93.27%) and turbidity reduction (92.88%) predictions, with the corresponding experimental values of 69.27, 97.59 and 96.91%, respectively. Springer Berlin Heidelberg 2019-02 Article PeerReviewed application/pdf en http://irep.iium.edu.my/64050/21/64050_Screening%20of%20electrocoagulation%20process.pdf application/pdf en http://irep.iium.edu.my/64050/19/64050_Screening%20of%20electrocoagulation%20process_SCOPUS.pdf application/pdf en http://irep.iium.edu.my/64050/20/64050_Screening%20of%20electrocoagulation%20process_WOS.pdf Mujeli, Mustapha and Hussain, S. A. and Ismail, M. H. S. and Awang Biak, Dayang Radiah and Jami, Mohammed Saedi (2019) Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution IV design. International Journal of Environmental Science and Technology, 16 (2). pp. 811-820. ISSN 1735-1472 https://link.springer.com/article/10.1007/s13762-018-1708-9 10.1007/s13762-018-1708-9
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
English
topic TP155 Chemical engineering
spellingShingle TP155 Chemical engineering
Mujeli, Mustapha
Hussain, S. A.
Ismail, M. H. S.
Awang Biak, Dayang Radiah
Jami, Mohammed Saedi
Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution IV design
description The present study aimed at the screening of parameters for electrocoagulation treatment of treated palm oil mill efuent using minimum-runs resolution IV design. The responses examined include: chemical oxygen demand removal (%), total suspended solids removal (%) and turbidity reduction (%), and the varied dependent factors comprise: electrical current density (mA/cm2), time (min), pH, electrolyte concentration (g/L), stirring speed (rpm), electrode spacing (mm) and electrode confguration (monopolar or dipolar). The statistical results revealed that the current density has a signifcant infuence on the treatment performance at two-level interactions with pH, electrode spacing and electrode concentration and at three-level correlations with time and pH. Thus, the most important factors afecting the removal efciency of the organic compounds were found to be pH, time, electrode spacing, electrolyte concentration and electrode confguration at a P value less than 0.05, respectively, in the descending order of signifcance. Therefore, the optimized electrocoagulation process could be reached with current density equal to 5 mA/cm2, electrolysis time of 5 min, electrode spacing of 5 mm and using monopolar electrode confguration. This combination provided the maximum ability of the process for chemical oxygen demand (68.84%), total suspended solids (93.27%) and turbidity reduction (92.88%) predictions, with the corresponding experimental values of 69.27, 97.59 and 96.91%, respectively.
format Article
author Mujeli, Mustapha
Hussain, S. A.
Ismail, M. H. S.
Awang Biak, Dayang Radiah
Jami, Mohammed Saedi
author_facet Mujeli, Mustapha
Hussain, S. A.
Ismail, M. H. S.
Awang Biak, Dayang Radiah
Jami, Mohammed Saedi
author_sort Mujeli, Mustapha
title Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution IV design
title_short Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution IV design
title_full Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution IV design
title_fullStr Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution IV design
title_full_unstemmed Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution IV design
title_sort screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution iv design
publisher Springer Berlin Heidelberg
publishDate 2019
url http://irep.iium.edu.my/64050/21/64050_Screening%20of%20electrocoagulation%20process.pdf
http://irep.iium.edu.my/64050/19/64050_Screening%20of%20electrocoagulation%20process_SCOPUS.pdf
http://irep.iium.edu.my/64050/20/64050_Screening%20of%20electrocoagulation%20process_WOS.pdf
http://irep.iium.edu.my/64050/
https://link.springer.com/article/10.1007/s13762-018-1708-9
_version_ 1643619330995257344