The use of maximum length sequence (MLS) stimuli to elicit an auditory brainstem response (ABR) has been limited, in part, by the observation that these stimuli reduce ABR wave amplitudes. This study recorded ABR waveforms from 14 normally hearing adults using MLS click stimuli (maximum stimulu...

Full description

Saved in:
Bibliographic Details
Main Authors: Dzulkarnain, Ahmad Aidil Arafat, Wilson, Wayne J., Bradley, Andrew P., Petoe, Matthew
Format: Article
Language:English
Published: S. Karger AG 2008
Subjects:
Online Access:http://irep.iium.edu.my/6545/2/Dzulkarnain2007EffectElectMontOnAmpWaveVABRMLS.pdf
http://irep.iium.edu.my/6545/
http://dx.doi.org/10.1159/000107432
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
id my.iium.irep.6545
record_format dspace
spelling my.iium.irep.65452022-04-12T02:50:21Z http://irep.iium.edu.my/6545/ The Effects of Electrode Montage on the Amplitude of Wave V in the Auditory Brainstem Response to Maximum Length Sequence Stimuli Dzulkarnain, Ahmad Aidil Arafat Wilson, Wayne J. Bradley, Andrew P. Petoe, Matthew R Medicine (General) The use of maximum length sequence (MLS) stimuli to elicit an auditory brainstem response (ABR) has been limited, in part, by the observation that these stimuli reduce ABR wave amplitudes. This study recorded ABR waveforms from 14 normally hearing adults using MLS click stimuli (maximum stimulus rate = 250 clicks per second) at stimulus levels of 70, 60, 50, 40, 30 and 20 dB nHL, with a vertical and then an ipsilateral electrode montage. The vertical electrode montage produced significantly larger (p ! 0.05) wave V amplitudes, with no change in wave V latencies (p 1 0.05), at all stimulus levels. This result suggests a vertical electrode montage could be used to counter some of the loss in wave V amplitude observed when using MLS stimuli. S. Karger AG 2008 Article PeerReviewed application/pdf en http://irep.iium.edu.my/6545/2/Dzulkarnain2007EffectElectMontOnAmpWaveVABRMLS.pdf Dzulkarnain, Ahmad Aidil Arafat and Wilson, Wayne J. and Bradley, Andrew P. and Petoe, Matthew (2008) The Effects of Electrode Montage on the Amplitude of Wave V in the Auditory Brainstem Response to Maximum Length Sequence Stimuli. Audiology and Neurotology, 13 (1). pp. 7-12. ISSN 1420-3030 http://dx.doi.org/10.1159/000107432 doi:10.1159/000107432
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic R Medicine (General)
spellingShingle R Medicine (General)
Dzulkarnain, Ahmad Aidil Arafat
Wilson, Wayne J.
Bradley, Andrew P.
Petoe, Matthew
The Effects of Electrode Montage on the Amplitude of Wave V in the Auditory Brainstem Response to Maximum Length Sequence Stimuli
description The use of maximum length sequence (MLS) stimuli to elicit an auditory brainstem response (ABR) has been limited, in part, by the observation that these stimuli reduce ABR wave amplitudes. This study recorded ABR waveforms from 14 normally hearing adults using MLS click stimuli (maximum stimulus rate = 250 clicks per second) at stimulus levels of 70, 60, 50, 40, 30 and 20 dB nHL, with a vertical and then an ipsilateral electrode montage. The vertical electrode montage produced significantly larger (p ! 0.05) wave V amplitudes, with no change in wave V latencies (p 1 0.05), at all stimulus levels. This result suggests a vertical electrode montage could be used to counter some of the loss in wave V amplitude observed when using MLS stimuli.
format Article
author Dzulkarnain, Ahmad Aidil Arafat
Wilson, Wayne J.
Bradley, Andrew P.
Petoe, Matthew
author_facet Dzulkarnain, Ahmad Aidil Arafat
Wilson, Wayne J.
Bradley, Andrew P.
Petoe, Matthew
author_sort Dzulkarnain, Ahmad Aidil Arafat
title The Effects of Electrode Montage on the Amplitude of Wave V in the Auditory Brainstem Response to Maximum Length Sequence Stimuli
title_short The Effects of Electrode Montage on the Amplitude of Wave V in the Auditory Brainstem Response to Maximum Length Sequence Stimuli
title_full The Effects of Electrode Montage on the Amplitude of Wave V in the Auditory Brainstem Response to Maximum Length Sequence Stimuli
title_fullStr The Effects of Electrode Montage on the Amplitude of Wave V in the Auditory Brainstem Response to Maximum Length Sequence Stimuli
title_full_unstemmed The Effects of Electrode Montage on the Amplitude of Wave V in the Auditory Brainstem Response to Maximum Length Sequence Stimuli
title_sort effects of electrode montage on the amplitude of wave v in the auditory brainstem response to maximum length sequence stimuli
publisher S. Karger AG
publishDate 2008
url http://irep.iium.edu.my/6545/2/Dzulkarnain2007EffectElectMontOnAmpWaveVABRMLS.pdf
http://irep.iium.edu.my/6545/
http://dx.doi.org/10.1159/000107432
_version_ 1731225358908260352