Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness

Introduction: A significant degree of corneal astigmatism can be induced by the encroachment of a pterygium onto a cornea. As various pterygium morphologies have been advocated as contributing factor on corneal astigmatism, little support in the literature available in establishing techniques in me...

Full description

Saved in:
Bibliographic Details
Main Authors: Hilmi, Mohd Radzi, Mohd. Kamal, Khairidzan, Che Azemin, Mohd Zulfaezal, Ariffin, Azrin Esmady
Format: Article
Language:English
English
Published: Medical Faculty of Sultan Agong Islamic University 2019
Subjects:
Online Access:http://irep.iium.edu.my/71535/1/Utilization%20of%20anterior%20segment%20optical%20coherence%20tomography%20enhanced%20high%20resolution%20corneal%20in%20measuring%20pterygium%20thickness.pdf
http://irep.iium.edu.my/71535/7/Editor_Author%20Correspondence.pdf
http://irep.iium.edu.my/71535/
http://jurnal.unissula.ac.id/index.php/sainsmedika/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
English
id my.iium.irep.71535
record_format dspace
spelling my.iium.irep.715352022-06-30T06:39:02Z http://irep.iium.edu.my/71535/ Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness Hilmi, Mohd Radzi Mohd. Kamal, Khairidzan Che Azemin, Mohd Zulfaezal Ariffin, Azrin Esmady RE Ophthalmology Introduction: A significant degree of corneal astigmatism can be induced by the encroachment of a pterygium onto a cornea. As various pterygium morphologies have been advocated as contributing factor on corneal astigmatism, little support in the literature available in establishing techniques in measuring pterygium thickness as clinical indicator. To further substantiate claims of establishing measurement of pterygium thickness, the aim of this study was to describe a quantitative method in determining pterygium thickness using anterior segment optical coherence tomography. Methods: Anterior segment imaging was performed using enhanced high resolution cornea of Visante™ optical coherence tomography in 120 primary pterygium eyes. Prior to imaging, corneal topography assessment was performed on each pterygium eye in order to identify its topographic location. Based on topography mapping, three meridians (in degrees) were selected as close as possible to the pterygium border, which signify the demarcation of pterygium from the cornea. Reliability testing between intra and inter-observer of optical coherence tomography imaging modality was examined using intraclass correlation and scatter plot. Results: The overall (n = 120) mean and standard deviation of pterygium thickness via enhanced high resolution cornea of optical coherence tomography modality were 0.48 ± 0.10 mm (confidence interval: 0.45 – 0.50). Optical coherence tomography imaging also showed excellent intra and intergrader reliability in measuring pterygium thickness with intraclass correlation of 0.997 (confidence interval: 0.994 – 0.998). Conclusions: Enhanced high resolution cornea of anterior segment optical coherence tomography imaging is a better choice in assessing pterygium compared to traditional slit-lamp biomicroscopy. This tool is applicable for future work related to better understanding on the role thickness in pterygium morphology, its progression and prediction of induced corneal astigmatism and visual impairment due to pterygium. Medical Faculty of Sultan Agong Islamic University 2019-07-24 Article PeerReviewed application/pdf en http://irep.iium.edu.my/71535/1/Utilization%20of%20anterior%20segment%20optical%20coherence%20tomography%20enhanced%20high%20resolution%20corneal%20in%20measuring%20pterygium%20thickness.pdf application/pdf en http://irep.iium.edu.my/71535/7/Editor_Author%20Correspondence.pdf Hilmi, Mohd Radzi and Mohd. Kamal, Khairidzan and Che Azemin, Mohd Zulfaezal and Ariffin, Azrin Esmady (2019) Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness. Journal of Medicine and Health (Sains medika), xx (xx). pp. 1-13. ISSN 2085-1545 E-ISSN 2339-093X (In Press) http://jurnal.unissula.ac.id/index.php/sainsmedika/
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic RE Ophthalmology
spellingShingle RE Ophthalmology
Hilmi, Mohd Radzi
Mohd. Kamal, Khairidzan
Che Azemin, Mohd Zulfaezal
Ariffin, Azrin Esmady
Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness
description Introduction: A significant degree of corneal astigmatism can be induced by the encroachment of a pterygium onto a cornea. As various pterygium morphologies have been advocated as contributing factor on corneal astigmatism, little support in the literature available in establishing techniques in measuring pterygium thickness as clinical indicator. To further substantiate claims of establishing measurement of pterygium thickness, the aim of this study was to describe a quantitative method in determining pterygium thickness using anterior segment optical coherence tomography. Methods: Anterior segment imaging was performed using enhanced high resolution cornea of Visante™ optical coherence tomography in 120 primary pterygium eyes. Prior to imaging, corneal topography assessment was performed on each pterygium eye in order to identify its topographic location. Based on topography mapping, three meridians (in degrees) were selected as close as possible to the pterygium border, which signify the demarcation of pterygium from the cornea. Reliability testing between intra and inter-observer of optical coherence tomography imaging modality was examined using intraclass correlation and scatter plot. Results: The overall (n = 120) mean and standard deviation of pterygium thickness via enhanced high resolution cornea of optical coherence tomography modality were 0.48 ± 0.10 mm (confidence interval: 0.45 – 0.50). Optical coherence tomography imaging also showed excellent intra and intergrader reliability in measuring pterygium thickness with intraclass correlation of 0.997 (confidence interval: 0.994 – 0.998). Conclusions: Enhanced high resolution cornea of anterior segment optical coherence tomography imaging is a better choice in assessing pterygium compared to traditional slit-lamp biomicroscopy. This tool is applicable for future work related to better understanding on the role thickness in pterygium morphology, its progression and prediction of induced corneal astigmatism and visual impairment due to pterygium.
format Article
author Hilmi, Mohd Radzi
Mohd. Kamal, Khairidzan
Che Azemin, Mohd Zulfaezal
Ariffin, Azrin Esmady
author_facet Hilmi, Mohd Radzi
Mohd. Kamal, Khairidzan
Che Azemin, Mohd Zulfaezal
Ariffin, Azrin Esmady
author_sort Hilmi, Mohd Radzi
title Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness
title_short Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness
title_full Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness
title_fullStr Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness
title_full_unstemmed Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness
title_sort utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness
publisher Medical Faculty of Sultan Agong Islamic University
publishDate 2019
url http://irep.iium.edu.my/71535/1/Utilization%20of%20anterior%20segment%20optical%20coherence%20tomography%20enhanced%20high%20resolution%20corneal%20in%20measuring%20pterygium%20thickness.pdf
http://irep.iium.edu.my/71535/7/Editor_Author%20Correspondence.pdf
http://irep.iium.edu.my/71535/
http://jurnal.unissula.ac.id/index.php/sainsmedika/
_version_ 1738510098976735232