A cost-effective data acquisition instrumentation for measurement of base pressure and wall pressure in suddenly expanded flow through ducts

Internal flow experimental studies such as sudden expansion in ducts have been reported in the literature. However, the methodology of arriving at the results is not discussed elaborately with the accent on the cost involved and time spent in acquiring the data. This paper explains in detail about t...

Full description

Saved in:
Bibliographic Details
Main Authors: Sethuraman, Vigneshvaran, Rajendran, Parvathy, Khan, Sher Afghan
Format: Article
Language:English
English
Published: Penerbit Akademia Baru 2019
Subjects:
Online Access:http://irep.iium.edu.my/74544/13/74544%20A%20Cost-effective%20Data%20Acquisition%20Instrumentation.pdf
http://irep.iium.edu.my/74544/14/74544%20A%20Cost-effective%20Data%20Acquisition%20Instrumentation%20SCOPUS.pdf
http://irep.iium.edu.my/74544/
http://www.akademiabaru.com/doc/ARFMTSV60_N1_P112_123.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
English
id my.iium.irep.74544
record_format dspace
spelling my.iium.irep.745442019-09-30T08:36:26Z http://irep.iium.edu.my/74544/ A cost-effective data acquisition instrumentation for measurement of base pressure and wall pressure in suddenly expanded flow through ducts Sethuraman, Vigneshvaran Rajendran, Parvathy Khan, Sher Afghan TL780 Rockets Internal flow experimental studies such as sudden expansion in ducts have been reported in the literature. However, the methodology of arriving at the results is not discussed elaborately with the accent on the cost involved and time spent in acquiring the data. This paper explains in detail about the experimental procedure, the methodology of arriving at results and the data analysis. The experimental setup with readily available commercial data acquisition instrumentation for a typical sudden expansion internal flow is presented. It was observed that apart from the cost of hardware fabrication, the cost of instrumentation and measuring devices is also huge. This is apparent especially in fluid flow problems, where there is a need to measure pressures at multiple locations. However, commercially available DAQs have a limited number of channels. Thus, the need for an alternative cost-effective data acquisition system (DAQ) with multiple channels is crucial. Hence, an alternate arrangement of DAQ which is considerably cost-effective and is equally efficient as that of the commercial instrument is proposed. The base pressure and wall pressure results obtained using fabricated DAQ had a variation of ± 1% and ± 1.5% respectively, in comparison to that of commercial DAQ. It is reported that these two arrangements give comparable results with very good accuracy and repeatability of results. Penerbit Akademia Baru 2019-08 Article PeerReviewed application/pdf en http://irep.iium.edu.my/74544/13/74544%20A%20Cost-effective%20Data%20Acquisition%20Instrumentation.pdf application/pdf en http://irep.iium.edu.my/74544/14/74544%20A%20Cost-effective%20Data%20Acquisition%20Instrumentation%20SCOPUS.pdf Sethuraman, Vigneshvaran and Rajendran, Parvathy and Khan, Sher Afghan (2019) A cost-effective data acquisition instrumentation for measurement of base pressure and wall pressure in suddenly expanded flow through ducts. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 60 (1). pp. 112-123. E-ISSN 2289-7879 http://www.akademiabaru.com/doc/ARFMTSV60_N1_P112_123.pdf
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic TL780 Rockets
spellingShingle TL780 Rockets
Sethuraman, Vigneshvaran
Rajendran, Parvathy
Khan, Sher Afghan
A cost-effective data acquisition instrumentation for measurement of base pressure and wall pressure in suddenly expanded flow through ducts
description Internal flow experimental studies such as sudden expansion in ducts have been reported in the literature. However, the methodology of arriving at the results is not discussed elaborately with the accent on the cost involved and time spent in acquiring the data. This paper explains in detail about the experimental procedure, the methodology of arriving at results and the data analysis. The experimental setup with readily available commercial data acquisition instrumentation for a typical sudden expansion internal flow is presented. It was observed that apart from the cost of hardware fabrication, the cost of instrumentation and measuring devices is also huge. This is apparent especially in fluid flow problems, where there is a need to measure pressures at multiple locations. However, commercially available DAQs have a limited number of channels. Thus, the need for an alternative cost-effective data acquisition system (DAQ) with multiple channels is crucial. Hence, an alternate arrangement of DAQ which is considerably cost-effective and is equally efficient as that of the commercial instrument is proposed. The base pressure and wall pressure results obtained using fabricated DAQ had a variation of ± 1% and ± 1.5% respectively, in comparison to that of commercial DAQ. It is reported that these two arrangements give comparable results with very good accuracy and repeatability of results.
format Article
author Sethuraman, Vigneshvaran
Rajendran, Parvathy
Khan, Sher Afghan
author_facet Sethuraman, Vigneshvaran
Rajendran, Parvathy
Khan, Sher Afghan
author_sort Sethuraman, Vigneshvaran
title A cost-effective data acquisition instrumentation for measurement of base pressure and wall pressure in suddenly expanded flow through ducts
title_short A cost-effective data acquisition instrumentation for measurement of base pressure and wall pressure in suddenly expanded flow through ducts
title_full A cost-effective data acquisition instrumentation for measurement of base pressure and wall pressure in suddenly expanded flow through ducts
title_fullStr A cost-effective data acquisition instrumentation for measurement of base pressure and wall pressure in suddenly expanded flow through ducts
title_full_unstemmed A cost-effective data acquisition instrumentation for measurement of base pressure and wall pressure in suddenly expanded flow through ducts
title_sort cost-effective data acquisition instrumentation for measurement of base pressure and wall pressure in suddenly expanded flow through ducts
publisher Penerbit Akademia Baru
publishDate 2019
url http://irep.iium.edu.my/74544/13/74544%20A%20Cost-effective%20Data%20Acquisition%20Instrumentation.pdf
http://irep.iium.edu.my/74544/14/74544%20A%20Cost-effective%20Data%20Acquisition%20Instrumentation%20SCOPUS.pdf
http://irep.iium.edu.my/74544/
http://www.akademiabaru.com/doc/ARFMTSV60_N1_P112_123.pdf
_version_ 1648739783224066048