Analysis of electrokinetic response of solid-liquid mixture during expression operation

In the expression process of slurry material using a filter-press of compression type, the process is divided into two periods: the filtration period and the consolidation period. Identification of the exact time of the culmination of filtration period is essential for operating the press effective...

Full description

Saved in:
Bibliographic Details
Main Authors: Iwata, Masashi, Shimoizu, Kazuya, Sadai, Haruna, Iwasaki, Tomohiro, Nakamura, Kazuho, Jami, Mohammed Saedi
Format: Article
Language:English
English
Published: Elsevier B.V. 2021
Subjects:
Online Access:http://irep.iium.edu.my/83365/1/83365_Analysis%20of%20electrokinetic%20response.pdf
http://irep.iium.edu.my/83365/2/83365_Analysis%20of%20electrokinetic%20response_SCOPUS.pdf
http://irep.iium.edu.my/83365/
https://www.sciencedirect.com/science/article/abs/pii/S1383586620322358
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
English
id my.iium.irep.83365
record_format dspace
spelling my.iium.irep.833652020-12-01T03:57:49Z http://irep.iium.edu.my/83365/ Analysis of electrokinetic response of solid-liquid mixture during expression operation Iwata, Masashi Shimoizu, Kazuya Sadai, Haruna Iwasaki, Tomohiro Nakamura, Kazuho Jami, Mohammed Saedi TP155 Chemical engineering In the expression process of slurry material using a filter-press of compression type, the process is divided into two periods: the filtration period and the consolidation period. Identification of the exact time of the culmination of filtration period is essential for operating the press effectively. This study focused on the electrokinetic phenomena during expression operation of zinc oxide slurry to obtain information on the status of the filter chamber. We have measured the time course of electrical potential difference (EPD) between both ends of expressed material during the expression process using a laboratory piston press. The absolute value of EPD increased with the progress of the filtration period, followed by the decrease during the consolidation period. It was observed that the time at which the absolute value of the EPD began to decline coincided with the time at which the filtration period ended. EPD reached the plateau value at the end of consolidation. In a consolidation of homogeneous semisolid material, the absolute value of EPD increased at the beginning of the operation, followed by the decline to the plateau value. We have extended the theoretical equation of streaming potential for a straight capillary to be applied to a tortuous flow path of the expressed material. The time course of EPD can be qualitatively explained by using the proposed equation for EPD and calculated liquid pressure distributions based on the conventional filtration and consolidation theories by considering the medium resistance. Elsevier B.V. 2021-02-01 Article PeerReviewed application/pdf en http://irep.iium.edu.my/83365/1/83365_Analysis%20of%20electrokinetic%20response.pdf application/pdf en http://irep.iium.edu.my/83365/2/83365_Analysis%20of%20electrokinetic%20response_SCOPUS.pdf Iwata, Masashi and Shimoizu, Kazuya and Sadai, Haruna and Iwasaki, Tomohiro and Nakamura, Kazuho and Jami, Mohammed Saedi (2021) Analysis of electrokinetic response of solid-liquid mixture during expression operation. Separation and Purification Technology, 256. pp. 1-10. ISSN 1383-5866 https://www.sciencedirect.com/science/article/abs/pii/S1383586620322358 10.1016/j.seppur.2020.117761
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic TP155 Chemical engineering
spellingShingle TP155 Chemical engineering
Iwata, Masashi
Shimoizu, Kazuya
Sadai, Haruna
Iwasaki, Tomohiro
Nakamura, Kazuho
Jami, Mohammed Saedi
Analysis of electrokinetic response of solid-liquid mixture during expression operation
description In the expression process of slurry material using a filter-press of compression type, the process is divided into two periods: the filtration period and the consolidation period. Identification of the exact time of the culmination of filtration period is essential for operating the press effectively. This study focused on the electrokinetic phenomena during expression operation of zinc oxide slurry to obtain information on the status of the filter chamber. We have measured the time course of electrical potential difference (EPD) between both ends of expressed material during the expression process using a laboratory piston press. The absolute value of EPD increased with the progress of the filtration period, followed by the decrease during the consolidation period. It was observed that the time at which the absolute value of the EPD began to decline coincided with the time at which the filtration period ended. EPD reached the plateau value at the end of consolidation. In a consolidation of homogeneous semisolid material, the absolute value of EPD increased at the beginning of the operation, followed by the decline to the plateau value. We have extended the theoretical equation of streaming potential for a straight capillary to be applied to a tortuous flow path of the expressed material. The time course of EPD can be qualitatively explained by using the proposed equation for EPD and calculated liquid pressure distributions based on the conventional filtration and consolidation theories by considering the medium resistance.
format Article
author Iwata, Masashi
Shimoizu, Kazuya
Sadai, Haruna
Iwasaki, Tomohiro
Nakamura, Kazuho
Jami, Mohammed Saedi
author_facet Iwata, Masashi
Shimoizu, Kazuya
Sadai, Haruna
Iwasaki, Tomohiro
Nakamura, Kazuho
Jami, Mohammed Saedi
author_sort Iwata, Masashi
title Analysis of electrokinetic response of solid-liquid mixture during expression operation
title_short Analysis of electrokinetic response of solid-liquid mixture during expression operation
title_full Analysis of electrokinetic response of solid-liquid mixture during expression operation
title_fullStr Analysis of electrokinetic response of solid-liquid mixture during expression operation
title_full_unstemmed Analysis of electrokinetic response of solid-liquid mixture during expression operation
title_sort analysis of electrokinetic response of solid-liquid mixture during expression operation
publisher Elsevier B.V.
publishDate 2021
url http://irep.iium.edu.my/83365/1/83365_Analysis%20of%20electrokinetic%20response.pdf
http://irep.iium.edu.my/83365/2/83365_Analysis%20of%20electrokinetic%20response_SCOPUS.pdf
http://irep.iium.edu.my/83365/
https://www.sciencedirect.com/science/article/abs/pii/S1383586620322358
_version_ 1685578537783787520