Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry
Ammonium ions (NH4+) are one of the indicators of water quality; high ammonium concentration [NH4+] in water can cause eutrophication and affect aquatic biota and can cause cell death in the central nervous system of human beings. However, current ion-selective electrodes used for water-quality moni...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
MDPI
2020
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/84243/7/84243_Fabrication%20of%20an%20all-solid-state%20ammonium%20ion%E2%80%93%20selective%20electrode.pdf http://irep.iium.edu.my/84243/ https://www.mdpi.com/journal/biosensors/special_issues/IECB2020_SI#published |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Islam Antarabangsa Malaysia |
Language: | English |
id |
my.iium.irep.84243 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.842432020-12-01T03:26:16Z http://irep.iium.edu.my/84243/ Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry Benoudjit, Abdelmohsen Abd-Wahab, Firdaus Wan Salim, Wan Wardatul Amani TD169 Environmental protection TP248.13 Biotechnology Ammonium ions (NH4+) are one of the indicators of water quality; high ammonium concentration [NH4+] in water can cause eutrophication and affect aquatic biota and can cause cell death in the central nervous system of human beings. However, current ion-selective electrodes used for water-quality monitoring are bulky, require frequent calibration owing to membrane fouling, and cannot be integrated into mobile sensor platforms. We fabricated an all-solid-state ion-selective electrode for ammonium ion (NH4+ISE) using a two-step process; first is electropolymerization deposition on the electrode using a solution of 3,4-ethylenedioxythiophene (EDOT), sodium polystyrene sulfonate (NaPSS), and o-phenylenediamine (OPD) resulting in a solid-state transducer on screen-printed carbon electrodes (SPCEs), and the second is electropolymerization of OPD as ion-selective membrane (ISM) on top of the transducer. The electropolymerization deposition of the transducer and the ISM were simply achieved by using cyclic voltammetry (CV) with potential from 0.0 V to 0.8 V and 50 mVs-1 scan rate. The fabricated NH4+ISE can detect [NH4+] as low as 4.8×10-5 M, with a slope of 20 mV/decade (R2>0.99) and a linear range from 4.8×10-5 M to 0.1 M. These preliminary results provide an initial insight into the applicability of the simple two-steps fabrication process of the NH4+ISEs for scaling-up purposes, with the ability for miniaturization and integration to a mobile sensor platform. MDPI 2020-11-02 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/84243/7/84243_Fabrication%20of%20an%20all-solid-state%20ammonium%20ion%E2%80%93%20selective%20electrode.pdf Benoudjit, Abdelmohsen and Abd-Wahab, Firdaus and Wan Salim, Wan Wardatul Amani (2020) Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry. In: 1st International Electronic Conference on Biosensors (IECB 2020), 2nd-17th November 2020, Online. https://www.mdpi.com/journal/biosensors/special_issues/IECB2020_SI#published |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
TD169 Environmental protection TP248.13 Biotechnology |
spellingShingle |
TD169 Environmental protection TP248.13 Biotechnology Benoudjit, Abdelmohsen Abd-Wahab, Firdaus Wan Salim, Wan Wardatul Amani Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry |
description |
Ammonium ions (NH4+) are one of the indicators of water quality; high ammonium concentration [NH4+] in water can cause eutrophication and affect aquatic biota and can cause cell death in the central nervous system of human beings. However, current ion-selective electrodes used for water-quality monitoring are bulky, require frequent calibration owing to membrane fouling, and cannot be integrated into mobile sensor platforms. We fabricated an all-solid-state ion-selective electrode for ammonium ion (NH4+ISE) using a two-step process; first is electropolymerization deposition on the electrode using a solution of 3,4-ethylenedioxythiophene (EDOT), sodium polystyrene sulfonate (NaPSS), and o-phenylenediamine (OPD) resulting in a solid-state transducer on screen-printed carbon electrodes (SPCEs), and the second is electropolymerization of OPD as ion-selective membrane (ISM) on top of the transducer. The electropolymerization deposition of the transducer and the ISM were simply achieved by using cyclic voltammetry (CV) with potential from 0.0 V to 0.8 V and 50 mVs-1 scan rate. The fabricated NH4+ISE can detect [NH4+] as low as 4.8×10-5 M, with a slope of 20 mV/decade (R2>0.99) and a linear range from 4.8×10-5 M to 0.1 M. These preliminary results provide an initial insight into the applicability of the simple two-steps fabrication process of the NH4+ISEs for scaling-up purposes, with the ability for miniaturization and integration to a mobile sensor platform. |
format |
Conference or Workshop Item |
author |
Benoudjit, Abdelmohsen Abd-Wahab, Firdaus Wan Salim, Wan Wardatul Amani |
author_facet |
Benoudjit, Abdelmohsen Abd-Wahab, Firdaus Wan Salim, Wan Wardatul Amani |
author_sort |
Benoudjit, Abdelmohsen |
title |
Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry |
title_short |
Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry |
title_full |
Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry |
title_fullStr |
Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry |
title_full_unstemmed |
Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry |
title_sort |
fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry |
publisher |
MDPI |
publishDate |
2020 |
url |
http://irep.iium.edu.my/84243/7/84243_Fabrication%20of%20an%20all-solid-state%20ammonium%20ion%E2%80%93%20selective%20electrode.pdf http://irep.iium.edu.my/84243/ https://www.mdpi.com/journal/biosensors/special_issues/IECB2020_SI#published |
_version_ |
1685578540434587648 |