Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry

Ammonium ions (NH4+) are one of the indicators of water quality; high ammonium concentration [NH4+] in water can cause eutrophication and affect aquatic biota and can cause cell death in the central nervous system of human beings. However, current ion-selective electrodes used for water-quality moni...

Full description

Saved in:
Bibliographic Details
Main Authors: Benoudjit, Abdelmohsen, Abd-Wahab, Firdaus, Wan Salim, Wan Wardatul Amani
Format: Conference or Workshop Item
Language:English
Published: MDPI 2020
Subjects:
Online Access:http://irep.iium.edu.my/84243/7/84243_Fabrication%20of%20an%20all-solid-state%20ammonium%20ion%E2%80%93%20selective%20electrode.pdf
http://irep.iium.edu.my/84243/
https://www.mdpi.com/journal/biosensors/special_issues/IECB2020_SI#published
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
id my.iium.irep.84243
record_format dspace
spelling my.iium.irep.842432020-12-01T03:26:16Z http://irep.iium.edu.my/84243/ Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry Benoudjit, Abdelmohsen Abd-Wahab, Firdaus Wan Salim, Wan Wardatul Amani TD169 Environmental protection TP248.13 Biotechnology Ammonium ions (NH4+) are one of the indicators of water quality; high ammonium concentration [NH4+] in water can cause eutrophication and affect aquatic biota and can cause cell death in the central nervous system of human beings. However, current ion-selective electrodes used for water-quality monitoring are bulky, require frequent calibration owing to membrane fouling, and cannot be integrated into mobile sensor platforms. We fabricated an all-solid-state ion-selective electrode for ammonium ion (NH4+ISE) using a two-step process; first is electropolymerization deposition on the electrode using a solution of 3,4-ethylenedioxythiophene (EDOT), sodium polystyrene sulfonate (NaPSS), and o-phenylenediamine (OPD) resulting in a solid-state transducer on screen-printed carbon electrodes (SPCEs), and the second is electropolymerization of OPD as ion-selective membrane (ISM) on top of the transducer. The electropolymerization deposition of the transducer and the ISM were simply achieved by using cyclic voltammetry (CV) with potential from 0.0 V to 0.8 V and 50 mVs-1 scan rate. The fabricated NH4+ISE can detect [NH4+] as low as 4.8×10-5 M, with a slope of 20 mV/decade (R2>0.99) and a linear range from 4.8×10-5 M to 0.1 M. These preliminary results provide an initial insight into the applicability of the simple two-steps fabrication process of the NH4+ISEs for scaling-up purposes, with the ability for miniaturization and integration to a mobile sensor platform. MDPI 2020-11-02 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/84243/7/84243_Fabrication%20of%20an%20all-solid-state%20ammonium%20ion%E2%80%93%20selective%20electrode.pdf Benoudjit, Abdelmohsen and Abd-Wahab, Firdaus and Wan Salim, Wan Wardatul Amani (2020) Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry. In: 1st International Electronic Conference on Biosensors (IECB 2020), 2nd-17th November 2020, Online. https://www.mdpi.com/journal/biosensors/special_issues/IECB2020_SI#published
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic TD169 Environmental protection
TP248.13 Biotechnology
spellingShingle TD169 Environmental protection
TP248.13 Biotechnology
Benoudjit, Abdelmohsen
Abd-Wahab, Firdaus
Wan Salim, Wan Wardatul Amani
Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry
description Ammonium ions (NH4+) are one of the indicators of water quality; high ammonium concentration [NH4+] in water can cause eutrophication and affect aquatic biota and can cause cell death in the central nervous system of human beings. However, current ion-selective electrodes used for water-quality monitoring are bulky, require frequent calibration owing to membrane fouling, and cannot be integrated into mobile sensor platforms. We fabricated an all-solid-state ion-selective electrode for ammonium ion (NH4+ISE) using a two-step process; first is electropolymerization deposition on the electrode using a solution of 3,4-ethylenedioxythiophene (EDOT), sodium polystyrene sulfonate (NaPSS), and o-phenylenediamine (OPD) resulting in a solid-state transducer on screen-printed carbon electrodes (SPCEs), and the second is electropolymerization of OPD as ion-selective membrane (ISM) on top of the transducer. The electropolymerization deposition of the transducer and the ISM were simply achieved by using cyclic voltammetry (CV) with potential from 0.0 V to 0.8 V and 50 mVs-1 scan rate. The fabricated NH4+ISE can detect [NH4+] as low as 4.8×10-5 M, with a slope of 20 mV/decade (R2>0.99) and a linear range from 4.8×10-5 M to 0.1 M. These preliminary results provide an initial insight into the applicability of the simple two-steps fabrication process of the NH4+ISEs for scaling-up purposes, with the ability for miniaturization and integration to a mobile sensor platform.
format Conference or Workshop Item
author Benoudjit, Abdelmohsen
Abd-Wahab, Firdaus
Wan Salim, Wan Wardatul Amani
author_facet Benoudjit, Abdelmohsen
Abd-Wahab, Firdaus
Wan Salim, Wan Wardatul Amani
author_sort Benoudjit, Abdelmohsen
title Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry
title_short Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry
title_full Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry
title_fullStr Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry
title_full_unstemmed Fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry
title_sort fabrication of an all-solid-state ammonium ion– selective electrode by a two-step process using cyclic voltammetry
publisher MDPI
publishDate 2020
url http://irep.iium.edu.my/84243/7/84243_Fabrication%20of%20an%20all-solid-state%20ammonium%20ion%E2%80%93%20selective%20electrode.pdf
http://irep.iium.edu.my/84243/
https://www.mdpi.com/journal/biosensors/special_issues/IECB2020_SI#published
_version_ 1685578540434587648