Mesopic pupillometry in pre-LASIK patients by a placido-disc topographer and hartmann-shack aberrometer

Introduction: Precise pupillometry is crucial to determine ablation optical zone (OZ) size selection in LASIK. Significant difference in the selection induces unwanted postoperative night visual disturbance. Placido-disc topographer and Hartmann-Shack aberrometer are commonly used in LASIK preopera...

Full description

Saved in:
Bibliographic Details
Main Authors: Md Mustafa, Md Muziman Syah, Suhaimi, Muhammad Aiman, Sulaiman, Umar Hakimi, Ab. Halim, Noorhazayti, Liza-Sharmini, Ahmad Tajudin, Mohd. Kamal, Khairidzan
Format: Article
Language:English
English
Published: Faculty of Medicine and Health Sciences, Universiti Putra Malaysia 2021
Subjects:
Online Access:http://irep.iium.edu.my/85703/1/85703_Mesopic%20pupillometry%20in%20pre-LASIK%20patients.pdf
http://irep.iium.edu.my/85703/2/85703_Mesopic%20pupillometry%20in%20pre-LASIK%20patients_SCOPUS.pdf
http://irep.iium.edu.my/85703/
https://medic.upm.edu.my/upload/dokumen/2021040613152927_MJMHS_0908.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
English
id my.iium.irep.85703
record_format dspace
spelling my.iium.irep.857032022-04-20T01:53:59Z http://irep.iium.edu.my/85703/ Mesopic pupillometry in pre-LASIK patients by a placido-disc topographer and hartmann-shack aberrometer Md Mustafa, Md Muziman Syah Suhaimi, Muhammad Aiman Sulaiman, Umar Hakimi Ab. Halim, Noorhazayti Liza-Sharmini, Ahmad Tajudin Mohd. Kamal, Khairidzan RE Ophthalmology Introduction: Precise pupillometry is crucial to determine ablation optical zone (OZ) size selection in LASIK. Significant difference in the selection induces unwanted postoperative night visual disturbance. Placido-disc topographer and Hartmann-Shack aberrometer are commonly used in LASIK preoperative assessment. However, little is known on the precision and agreement of these devices in pupillometry. Hence, this study aimed to evaluate the precision (repeatability and reproducibility) and inter-device agreement of a Placido-disc topographer and Hartmann-Shack aberrometer in measuring mesopic pupil size in pre-LASIK patients. Methods: Mesopic pupillometry on 38 pre-LASIK patients were performed using both devices by two masked operators, on two separate sessions. Intra-session repeatability, inter-operator reproducibility and inter-device agreement were analysed. A disagreement value of ±0.5 mm and 95% limits of agreement (LoA) were determined. Results: Hartmann-Shack aberrometer demonstrated higher repeatability and reproducibility than Placido-disc topographer in mesopic pupillometry. Ninety-seven percent and all of Hartmann-Shack wavefront aberrometer pupillometry were within ±0.5 mm in repeated sessions and between the operators, respectively. The mesopic pupil size obtained from Placido-disc topographer was significantly larger than Hartmann-Shack aberrometer results (P = 0.02). The agreement between devices was low (LoA > ±1 mm) and only 53% of Placido-disc topographer pupillometry were within ±0.5 mm of Hartmann-Shack aberrometer pupillometry. Conclusion: Hartmann-Shack aberrometer has higher precision within sessions and between operators, and it provides smaller mesopic pupillometry than Placido-disc topographer. Precise mesopic pupillometry could assist refractive surgeons in choosing a correct ablation OZ size during LASIK surgery to improve postoperative outcome. Faculty of Medicine and Health Sciences, Universiti Putra Malaysia 2021-04 Article PeerReviewed application/pdf en http://irep.iium.edu.my/85703/1/85703_Mesopic%20pupillometry%20in%20pre-LASIK%20patients.pdf application/pdf en http://irep.iium.edu.my/85703/2/85703_Mesopic%20pupillometry%20in%20pre-LASIK%20patients_SCOPUS.pdf Md Mustafa, Md Muziman Syah and Suhaimi, Muhammad Aiman and Sulaiman, Umar Hakimi and Ab. Halim, Noorhazayti and Liza-Sharmini, Ahmad Tajudin and Mohd. Kamal, Khairidzan (2021) Mesopic pupillometry in pre-LASIK patients by a placido-disc topographer and hartmann-shack aberrometer. Malaysian Journal of Medicine and Health Sciences, 17 (2). pp. 197-202. ISSN 1675-8544 https://medic.upm.edu.my/upload/dokumen/2021040613152927_MJMHS_0908.pdf
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic RE Ophthalmology
spellingShingle RE Ophthalmology
Md Mustafa, Md Muziman Syah
Suhaimi, Muhammad Aiman
Sulaiman, Umar Hakimi
Ab. Halim, Noorhazayti
Liza-Sharmini, Ahmad Tajudin
Mohd. Kamal, Khairidzan
Mesopic pupillometry in pre-LASIK patients by a placido-disc topographer and hartmann-shack aberrometer
description Introduction: Precise pupillometry is crucial to determine ablation optical zone (OZ) size selection in LASIK. Significant difference in the selection induces unwanted postoperative night visual disturbance. Placido-disc topographer and Hartmann-Shack aberrometer are commonly used in LASIK preoperative assessment. However, little is known on the precision and agreement of these devices in pupillometry. Hence, this study aimed to evaluate the precision (repeatability and reproducibility) and inter-device agreement of a Placido-disc topographer and Hartmann-Shack aberrometer in measuring mesopic pupil size in pre-LASIK patients. Methods: Mesopic pupillometry on 38 pre-LASIK patients were performed using both devices by two masked operators, on two separate sessions. Intra-session repeatability, inter-operator reproducibility and inter-device agreement were analysed. A disagreement value of ±0.5 mm and 95% limits of agreement (LoA) were determined. Results: Hartmann-Shack aberrometer demonstrated higher repeatability and reproducibility than Placido-disc topographer in mesopic pupillometry. Ninety-seven percent and all of Hartmann-Shack wavefront aberrometer pupillometry were within ±0.5 mm in repeated sessions and between the operators, respectively. The mesopic pupil size obtained from Placido-disc topographer was significantly larger than Hartmann-Shack aberrometer results (P = 0.02). The agreement between devices was low (LoA > ±1 mm) and only 53% of Placido-disc topographer pupillometry were within ±0.5 mm of Hartmann-Shack aberrometer pupillometry. Conclusion: Hartmann-Shack aberrometer has higher precision within sessions and between operators, and it provides smaller mesopic pupillometry than Placido-disc topographer. Precise mesopic pupillometry could assist refractive surgeons in choosing a correct ablation OZ size during LASIK surgery to improve postoperative outcome.
format Article
author Md Mustafa, Md Muziman Syah
Suhaimi, Muhammad Aiman
Sulaiman, Umar Hakimi
Ab. Halim, Noorhazayti
Liza-Sharmini, Ahmad Tajudin
Mohd. Kamal, Khairidzan
author_facet Md Mustafa, Md Muziman Syah
Suhaimi, Muhammad Aiman
Sulaiman, Umar Hakimi
Ab. Halim, Noorhazayti
Liza-Sharmini, Ahmad Tajudin
Mohd. Kamal, Khairidzan
author_sort Md Mustafa, Md Muziman Syah
title Mesopic pupillometry in pre-LASIK patients by a placido-disc topographer and hartmann-shack aberrometer
title_short Mesopic pupillometry in pre-LASIK patients by a placido-disc topographer and hartmann-shack aberrometer
title_full Mesopic pupillometry in pre-LASIK patients by a placido-disc topographer and hartmann-shack aberrometer
title_fullStr Mesopic pupillometry in pre-LASIK patients by a placido-disc topographer and hartmann-shack aberrometer
title_full_unstemmed Mesopic pupillometry in pre-LASIK patients by a placido-disc topographer and hartmann-shack aberrometer
title_sort mesopic pupillometry in pre-lasik patients by a placido-disc topographer and hartmann-shack aberrometer
publisher Faculty of Medicine and Health Sciences, Universiti Putra Malaysia
publishDate 2021
url http://irep.iium.edu.my/85703/1/85703_Mesopic%20pupillometry%20in%20pre-LASIK%20patients.pdf
http://irep.iium.edu.my/85703/2/85703_Mesopic%20pupillometry%20in%20pre-LASIK%20patients_SCOPUS.pdf
http://irep.iium.edu.my/85703/
https://medic.upm.edu.my/upload/dokumen/2021040613152927_MJMHS_0908.pdf
_version_ 1731225365463957504