Optimization of combined thermal power plant and performance analysis using matlab/simulink using real data: Kuwait as a case study
To increase the overall plant efficiency, the Combined cycle power plant (CCPP), which is a combination of the Gas turbine (Brayton cycle) and steam turbine (Rankine cycle), is a highly efficient system for electricity generation. In this paper, optimization and performance simulation analysis of Su...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
AlamBiblio Publishers
2021
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/90270/7/90270_Optimization%20of%20combined%20thermal%20power%20plant%20and%20performance%20analysis.pdf http://irep.iium.edu.my/90270/ https://journals.alambiblio.com/ojs/index.php/ajoeee/article/download/13/8/59 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Islam Antarabangsa Malaysia |
Language: | English |
id |
my.iium.irep.90270 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.902702021-06-17T07:38:52Z http://irep.iium.edu.my/90270/ Optimization of combined thermal power plant and performance analysis using matlab/simulink using real data: Kuwait as a case study Alshammari, Meshari F A F Toha, Siti Fauziah Anuar, Hazleen Buys, Yose Fachmi TK2896 Production of electricity by direct energy conversion To increase the overall plant efficiency, the Combined cycle power plant (CCPP), which is a combination of the Gas turbine (Brayton cycle) and steam turbine (Rankine cycle), is a highly efficient system for electricity generation. In this paper, optimization and performance simulation analysis of Subiyah Combined Thermal Power Plant using real operating data is performed. The model is developed usingMATLAB software. The main factors in the top and bottom cycles of the combined cycle are investigated and discussed. The simulation results demonstrate the exhaust of the Gas turbine reached up to 600°C. The net-power output based on the performance model using MATLAB (Simulink) is greater than the station's current real output by 20.5%. The overall thermal efficiency of the power plant is also raised from 50.5% to 55.2%. AlamBiblio Publishers 2021-04-20 Article PeerReviewed application/pdf en http://irep.iium.edu.my/90270/7/90270_Optimization%20of%20combined%20thermal%20power%20plant%20and%20performance%20analysis.pdf Alshammari, Meshari F A F and Toha, Siti Fauziah and Anuar, Hazleen and Buys, Yose Fachmi (2021) Optimization of combined thermal power plant and performance analysis using matlab/simulink using real data: Kuwait as a case study. Asian Journal Of Electrical And Electronic Engineering, 1 (1). pp. 42-49. E-ISSN 2785-8189 https://journals.alambiblio.com/ojs/index.php/ajoeee/article/download/13/8/59 |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
TK2896 Production of electricity by direct energy conversion |
spellingShingle |
TK2896 Production of electricity by direct energy conversion Alshammari, Meshari F A F Toha, Siti Fauziah Anuar, Hazleen Buys, Yose Fachmi Optimization of combined thermal power plant and performance analysis using matlab/simulink using real data: Kuwait as a case study |
description |
To increase the overall plant efficiency, the Combined cycle power plant (CCPP), which is a combination of the Gas turbine (Brayton cycle) and steam turbine (Rankine cycle), is a highly efficient system for electricity generation. In this paper, optimization and performance simulation analysis of Subiyah Combined Thermal Power Plant using real operating data is performed. The model is developed usingMATLAB software. The main factors in the top and bottom cycles of the combined cycle are investigated and discussed. The simulation results demonstrate the exhaust of the Gas turbine reached up to 600°C. The net-power output based on the performance model using MATLAB (Simulink) is greater than the station's current real output by 20.5%. The overall thermal efficiency of the power plant is also raised from 50.5% to 55.2%. |
format |
Article |
author |
Alshammari, Meshari F A F Toha, Siti Fauziah Anuar, Hazleen Buys, Yose Fachmi |
author_facet |
Alshammari, Meshari F A F Toha, Siti Fauziah Anuar, Hazleen Buys, Yose Fachmi |
author_sort |
Alshammari, Meshari F A F |
title |
Optimization of combined thermal power plant and performance analysis using matlab/simulink using real data: Kuwait as a case study |
title_short |
Optimization of combined thermal power plant and performance analysis using matlab/simulink using real data: Kuwait as a case study |
title_full |
Optimization of combined thermal power plant and performance analysis using matlab/simulink using real data: Kuwait as a case study |
title_fullStr |
Optimization of combined thermal power plant and performance analysis using matlab/simulink using real data: Kuwait as a case study |
title_full_unstemmed |
Optimization of combined thermal power plant and performance analysis using matlab/simulink using real data: Kuwait as a case study |
title_sort |
optimization of combined thermal power plant and performance analysis using matlab/simulink using real data: kuwait as a case study |
publisher |
AlamBiblio Publishers |
publishDate |
2021 |
url |
http://irep.iium.edu.my/90270/7/90270_Optimization%20of%20combined%20thermal%20power%20plant%20and%20performance%20analysis.pdf http://irep.iium.edu.my/90270/ https://journals.alambiblio.com/ojs/index.php/ajoeee/article/download/13/8/59 |
_version_ |
1703960217236013056 |