The repeatability of smith's method in measuring anterior chamber depth
Aims: The aim of this study is to assess the intra-observer repeatability and the inter-observer limits of agreement of the Smith’s technique in measuring ACD. Methodology:Twenty-two healthy participants with range of age from 24 to 25 were examined on their ACD by two examiners and in two sessio...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Kulliyyah of Allied Health Sciences, International Islamic University MalaysiaIUM Press
2021
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/99996/2/99996_The%20repeatability%20of%20smith%27s%20method%20in%20measuring%20anterior%20chamber%20depth.pdf http://irep.iium.edu.my/99996/ https://journals.iium.edu.my/ijahs/index.php/IJAHS/article/view/674 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Islam Antarabangsa Malaysia |
Language: | English |
id |
my.iium.irep.99996 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.999962022-09-15T04:15:17Z http://irep.iium.edu.my/99996/ The repeatability of smith's method in measuring anterior chamber depth Sidek, Nur 'Izzati Yusof @ Alias, Firdaus RE Ophthalmology Aims: The aim of this study is to assess the intra-observer repeatability and the inter-observer limits of agreement of the Smith’s technique in measuring ACD. Methodology:Twenty-two healthy participants with range of age from 24 to 25 were examined on their ACD by two examiners and in two sessions. Results: The mean difference for intra-observer was -0.04±0.29 mm with limits of agreement (LoA) of -0.60 to +0.52 mm and inter-observer mean difference was -0.09±0.30 mm with LoA of -0.68 to +0.50 mm. The ICC findings for intra-observer repeatability was 0.482 with 95% confident interval = 0.085 –0.746. For the inter-observer agreement, the ICC result was0.594 with 95% confident interval = 0.022 –0.831. Conclusion: The Smith’s technique in estimating ACD is repeatable upon measurement by different examiners and the values are repeatable upon measurement at different sessions. Hence, the Smith’s technique can be used with a moderate degree of repeatability and agreement to monitor longitudinal changes in the ACD. Kulliyyah of Allied Health Sciences, International Islamic University MalaysiaIUM Press 2021-06-15 Article PeerReviewed application/pdf en http://irep.iium.edu.my/99996/2/99996_The%20repeatability%20of%20smith%27s%20method%20in%20measuring%20anterior%20chamber%20depth.pdf Sidek, Nur 'Izzati and Yusof @ Alias, Firdaus (2021) The repeatability of smith's method in measuring anterior chamber depth. International Journal of Allied Health Sciences, 5 (3). p. 2262. E-ISSN 2600-8491 https://journals.iium.edu.my/ijahs/index.php/IJAHS/article/view/674 |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
RE Ophthalmology |
spellingShingle |
RE Ophthalmology Sidek, Nur 'Izzati Yusof @ Alias, Firdaus The repeatability of smith's method in measuring anterior chamber depth |
description |
Aims: The aim of this study is to assess the intra-observer repeatability and the inter-observer limits of agreement of the Smith’s technique in measuring ACD.
Methodology:Twenty-two healthy participants with range of age from 24 to 25 were examined on their ACD by two examiners and in two sessions.
Results: The mean difference for intra-observer was -0.04±0.29 mm with limits of agreement (LoA) of -0.60 to +0.52 mm and inter-observer mean difference was -0.09±0.30 mm with LoA of -0.68 to +0.50 mm. The ICC findings for intra-observer repeatability was 0.482 with 95% confident interval = 0.085 –0.746. For the inter-observer agreement, the ICC result was0.594 with 95% confident interval = 0.022 –0.831.
Conclusion: The Smith’s technique in estimating ACD is repeatable upon measurement by different examiners and the values are repeatable upon measurement at different sessions. Hence, the Smith’s technique can be used with a moderate degree of repeatability and agreement to monitor longitudinal changes in the ACD. |
format |
Article |
author |
Sidek, Nur 'Izzati Yusof @ Alias, Firdaus |
author_facet |
Sidek, Nur 'Izzati Yusof @ Alias, Firdaus |
author_sort |
Sidek, Nur 'Izzati |
title |
The repeatability of smith's method in measuring anterior chamber depth |
title_short |
The repeatability of smith's method in measuring anterior chamber depth |
title_full |
The repeatability of smith's method in measuring anterior chamber depth |
title_fullStr |
The repeatability of smith's method in measuring anterior chamber depth |
title_full_unstemmed |
The repeatability of smith's method in measuring anterior chamber depth |
title_sort |
repeatability of smith's method in measuring anterior chamber depth |
publisher |
Kulliyyah of Allied Health Sciences, International Islamic University MalaysiaIUM Press |
publishDate |
2021 |
url |
http://irep.iium.edu.my/99996/2/99996_The%20repeatability%20of%20smith%27s%20method%20in%20measuring%20anterior%20chamber%20depth.pdf http://irep.iium.edu.my/99996/ https://journals.iium.edu.my/ijahs/index.php/IJAHS/article/view/674 |
_version_ |
1744353537662386176 |