Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres

Glow curve is a key element in thermoluminescence (TL) studies as it provides on-the-ground understanding on the trapping mechanism inside the crystal lattice and hence stability of the TL material. In the present work, luminescence mechanism of the in-house fabricated germanium doped (Ge-doped) fla...

Full description

Saved in:
Bibliographic Details
Main Authors: Hassan, M.F., W.N., Rahman, Akagi, T., Sulaiman, N.S., Bradley, D.A. *, Noor, N. M.
Format: Article
Published: Elsevier 2023
Subjects:
Online Access:http://eprints.sunway.edu.my/2237/
https://doi.org/10.1016/j.radphyschem.2022.110521
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Sunway University
id my.sunway.eprints.2237
record_format eprints
spelling my.sunway.eprints.22372023-06-09T06:08:34Z http://eprints.sunway.edu.my/2237/ Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres Hassan, M.F. W.N., Rahman Akagi, T. Sulaiman, N.S. Bradley, D.A. * Noor, N. M. QC Physics Glow curve is a key element in thermoluminescence (TL) studies as it provides on-the-ground understanding on the trapping mechanism inside the crystal lattice and hence stability of the TL material. In the present work, luminescence mechanism of the in-house fabricated germanium doped (Ge-doped) flat-shape silica optical fibres have been investigated following irradiation by 150-MeV proton beams. Results of TL dose-response showed that there is a linear relationship between TL response and proton doses from 1 to 10 Gy, with a coefficient of determination close to one. The structure of glow curve remains unchanged throughout the studied dose range with a maximum glow peak dominated at temperature of within 250–290 ◦C. A Tmax-Tstop plot reveals not only horizontal regions but also smooth slopes, indicative of the presence of a continuum distribution of glow peaks and trap depth. A computerised glow curve deconvolution analysis of the respective fibre glow-curves demonstrated that they were composed of five strongly overlapping peaks underlying a broad TL spectrum, obtaining figures of merit in the range of 0.56–1.64%. The main physical kinetic parameters (activation energy and frequency factor) of the fitted glow peaks were obtained using GlowFit software. The data suggest that the TL glow peaks of the Ge-doped silica optical fibres obey second-order kinetics. Elsevier 2023-01 Article PeerReviewed Hassan, M.F. and W.N., Rahman and Akagi, T. and Sulaiman, N.S. and Bradley, D.A. * and Noor, N. M. (2023) Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres. Radiation Physics and Chemistry, 202. ISSN 0969-806X https://doi.org/10.1016/j.radphyschem.2022.110521 10.1016/j.radphyschem.2022.110521
institution Sunway University
building Sunway Campus Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Sunway University
content_source Sunway Institutional Repository
url_provider http://eprints.sunway.edu.my/
topic QC Physics
spellingShingle QC Physics
Hassan, M.F.
W.N., Rahman
Akagi, T.
Sulaiman, N.S.
Bradley, D.A. *
Noor, N. M.
Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres
description Glow curve is a key element in thermoluminescence (TL) studies as it provides on-the-ground understanding on the trapping mechanism inside the crystal lattice and hence stability of the TL material. In the present work, luminescence mechanism of the in-house fabricated germanium doped (Ge-doped) flat-shape silica optical fibres have been investigated following irradiation by 150-MeV proton beams. Results of TL dose-response showed that there is a linear relationship between TL response and proton doses from 1 to 10 Gy, with a coefficient of determination close to one. The structure of glow curve remains unchanged throughout the studied dose range with a maximum glow peak dominated at temperature of within 250–290 ◦C. A Tmax-Tstop plot reveals not only horizontal regions but also smooth slopes, indicative of the presence of a continuum distribution of glow peaks and trap depth. A computerised glow curve deconvolution analysis of the respective fibre glow-curves demonstrated that they were composed of five strongly overlapping peaks underlying a broad TL spectrum, obtaining figures of merit in the range of 0.56–1.64%. The main physical kinetic parameters (activation energy and frequency factor) of the fitted glow peaks were obtained using GlowFit software. The data suggest that the TL glow peaks of the Ge-doped silica optical fibres obey second-order kinetics.
format Article
author Hassan, M.F.
W.N., Rahman
Akagi, T.
Sulaiman, N.S.
Bradley, D.A. *
Noor, N. M.
author_facet Hassan, M.F.
W.N., Rahman
Akagi, T.
Sulaiman, N.S.
Bradley, D.A. *
Noor, N. M.
author_sort Hassan, M.F.
title Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres
title_short Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres
title_full Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres
title_fullStr Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres
title_full_unstemmed Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres
title_sort thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres
publisher Elsevier
publishDate 2023
url http://eprints.sunway.edu.my/2237/
https://doi.org/10.1016/j.radphyschem.2022.110521
_version_ 1769846263653597184