Using CR-39 Solid State Nuclear Track Detector (SSNTD) for long term monitoring of indoor and outdoor radon gas at Kuala Terengganu / Ainujariah Abdul Rahman @ Mohamad

Radon is a radioactive gas that comes from the radioactive decay of uranium, which is present in small amounts almost everywhere in the Earth's crust. If radon is inhaled, it can cause harm to cells in the lungs and elsewhere. This can increased risk of cancer. Due to this, Kuala Terengganu was...

Full description

Saved in:
Bibliographic Details
Main Author: Abdul Rahman @ Mohamad, Ainujariah
Format: Thesis
Language:English
Published: 2009
Online Access:https://ir.uitm.edu.my/id/eprint/100933/1/100933.pdf
https://ir.uitm.edu.my/id/eprint/100933/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Mara
Language: English
id my.uitm.ir.100933
record_format eprints
spelling my.uitm.ir.1009332024-08-22T16:58:25Z https://ir.uitm.edu.my/id/eprint/100933/ Using CR-39 Solid State Nuclear Track Detector (SSNTD) for long term monitoring of indoor and outdoor radon gas at Kuala Terengganu / Ainujariah Abdul Rahman @ Mohamad Abdul Rahman @ Mohamad, Ainujariah Radon is a radioactive gas that comes from the radioactive decay of uranium, which is present in small amounts almost everywhere in the Earth's crust. If radon is inhaled, it can cause harm to cells in the lungs and elsewhere. This can increased risk of cancer. Due to this, Kuala Terengganu was selected as the study area. Objectives of this study are to determine the level of radon activity concentrations in selected houses in Kuala Terengganu, Terengganu using SSNTD technique, to calibrate CR-39 SSNTD radon track detection efficiency, to compare the activity concentration with the global range value and to evaluate the possible risk that may cause by radon in the area. Technique that use for this study is SSNTD dosimeter which are the cheapest long-term monitoring device for alpha radiation from radon gas and radon daughters. Two dosimeters were located for indoor and outdoor at each selected study area. 24 houses were selected for this study. The dosimeters were collected after 105 days and brought to the laboratory. In the laboratory, SSNTD will chemically etch for 6 hours using NaOH, 6 M solutions at 70°C in the oil bath. Detectors will then washed with tap water, distilled water and drained prior to microscope inspection. From the result, the radon concentration for indoor and outdoor and annual effective dose was calculated. The radon mean concentration for indoor and outdoor is 1.18 pCi/L and a 0.28 pCi/L and the dose level ranged for our study is between 0.59 mSv/y and 1.83 mSv/y. 2009 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/100933/1/100933.pdf Using CR-39 Solid State Nuclear Track Detector (SSNTD) for long term monitoring of indoor and outdoor radon gas at Kuala Terengganu / Ainujariah Abdul Rahman @ Mohamad. (2009) Degree thesis, thesis, Universiti Teknologi MARA (UiTM).
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
description Radon is a radioactive gas that comes from the radioactive decay of uranium, which is present in small amounts almost everywhere in the Earth's crust. If radon is inhaled, it can cause harm to cells in the lungs and elsewhere. This can increased risk of cancer. Due to this, Kuala Terengganu was selected as the study area. Objectives of this study are to determine the level of radon activity concentrations in selected houses in Kuala Terengganu, Terengganu using SSNTD technique, to calibrate CR-39 SSNTD radon track detection efficiency, to compare the activity concentration with the global range value and to evaluate the possible risk that may cause by radon in the area. Technique that use for this study is SSNTD dosimeter which are the cheapest long-term monitoring device for alpha radiation from radon gas and radon daughters. Two dosimeters were located for indoor and outdoor at each selected study area. 24 houses were selected for this study. The dosimeters were collected after 105 days and brought to the laboratory. In the laboratory, SSNTD will chemically etch for 6 hours using NaOH, 6 M solutions at 70°C in the oil bath. Detectors will then washed with tap water, distilled water and drained prior to microscope inspection. From the result, the radon concentration for indoor and outdoor and annual effective dose was calculated. The radon mean concentration for indoor and outdoor is 1.18 pCi/L and a 0.28 pCi/L and the dose level ranged for our study is between 0.59 mSv/y and 1.83 mSv/y.
format Thesis
author Abdul Rahman @ Mohamad, Ainujariah
spellingShingle Abdul Rahman @ Mohamad, Ainujariah
Using CR-39 Solid State Nuclear Track Detector (SSNTD) for long term monitoring of indoor and outdoor radon gas at Kuala Terengganu / Ainujariah Abdul Rahman @ Mohamad
author_facet Abdul Rahman @ Mohamad, Ainujariah
author_sort Abdul Rahman @ Mohamad, Ainujariah
title Using CR-39 Solid State Nuclear Track Detector (SSNTD) for long term monitoring of indoor and outdoor radon gas at Kuala Terengganu / Ainujariah Abdul Rahman @ Mohamad
title_short Using CR-39 Solid State Nuclear Track Detector (SSNTD) for long term monitoring of indoor and outdoor radon gas at Kuala Terengganu / Ainujariah Abdul Rahman @ Mohamad
title_full Using CR-39 Solid State Nuclear Track Detector (SSNTD) for long term monitoring of indoor and outdoor radon gas at Kuala Terengganu / Ainujariah Abdul Rahman @ Mohamad
title_fullStr Using CR-39 Solid State Nuclear Track Detector (SSNTD) for long term monitoring of indoor and outdoor radon gas at Kuala Terengganu / Ainujariah Abdul Rahman @ Mohamad
title_full_unstemmed Using CR-39 Solid State Nuclear Track Detector (SSNTD) for long term monitoring of indoor and outdoor radon gas at Kuala Terengganu / Ainujariah Abdul Rahman @ Mohamad
title_sort using cr-39 solid state nuclear track detector (ssntd) for long term monitoring of indoor and outdoor radon gas at kuala terengganu / ainujariah abdul rahman @ mohamad
publishDate 2009
url https://ir.uitm.edu.my/id/eprint/100933/1/100933.pdf
https://ir.uitm.edu.my/id/eprint/100933/
_version_ 1808976139444551680