Automated Hypertensive Retinopathy detection using image processing / Muhammad Imran Rahmat

In this day and age, hypertensive has been identified as the major factor for death and is ranked third as a cause of life-years adapted for disability. Hypertensive retinopathy can be observed on the retinal sign, including generalized and focal arteriolar narrowing, arteriovenous nicking, flame-sh...

Full description

Saved in:
Bibliographic Details
Main Author: Rahmat, Muhammad Imran
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/31492/1/31492.pdf
http://ir.uitm.edu.my/id/eprint/31492/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Mara
Language: English
id my.uitm.ir.31492
record_format eprints
spelling my.uitm.ir.314922020-06-26T04:17:56Z http://ir.uitm.edu.my/id/eprint/31492/ Automated Hypertensive Retinopathy detection using image processing / Muhammad Imran Rahmat Rahmat, Muhammad Imran Data processing. Computer applications Electronic Computers. Computer Science In this day and age, hypertensive has been identified as the major factor for death and is ranked third as a cause of life-years adapted for disability. Hypertensive retinopathy can be observed on the retinal sign, including generalized and focal arteriolar narrowing, arteriovenous nicking, flame-shaped and blotted-shaped retinal haemorrhages, cotton-wool spots and swelling of the optic disc. Hypertensive retinopathy also relates to a condition of the disease that damages the retinal vascularization of hypertensive patients, leading to vision loss and death. However, there are no early symptoms to many eye diseases. It may be painless, and there may be no vision change until the disease is quite advanced. Hence, early detection is therefore really important to avoid any significant effect to human eyes. An automated hypertensive retinopathy detection prototype will be developed for medical examination in this project. There are three phases of this system which is pre-processing, processing and post processing. Several image processing technique has been use in development of this project. The accuracy of this system is 90.00% and it is developed using MATLAB software. The findings from this study is believed to be helpful as it may contribute in medical image processing field. 2020 Thesis NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/31492/1/31492.pdf Rahmat, Muhammad Imran (2020) Automated Hypertensive Retinopathy detection using image processing / Muhammad Imran Rahmat. Degree thesis, Universiti Teknologi MARA, Cawangan Melaka.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Data processing. Computer applications
Electronic Computers. Computer Science
spellingShingle Data processing. Computer applications
Electronic Computers. Computer Science
Rahmat, Muhammad Imran
Automated Hypertensive Retinopathy detection using image processing / Muhammad Imran Rahmat
description In this day and age, hypertensive has been identified as the major factor for death and is ranked third as a cause of life-years adapted for disability. Hypertensive retinopathy can be observed on the retinal sign, including generalized and focal arteriolar narrowing, arteriovenous nicking, flame-shaped and blotted-shaped retinal haemorrhages, cotton-wool spots and swelling of the optic disc. Hypertensive retinopathy also relates to a condition of the disease that damages the retinal vascularization of hypertensive patients, leading to vision loss and death. However, there are no early symptoms to many eye diseases. It may be painless, and there may be no vision change until the disease is quite advanced. Hence, early detection is therefore really important to avoid any significant effect to human eyes. An automated hypertensive retinopathy detection prototype will be developed for medical examination in this project. There are three phases of this system which is pre-processing, processing and post processing. Several image processing technique has been use in development of this project. The accuracy of this system is 90.00% and it is developed using MATLAB software. The findings from this study is believed to be helpful as it may contribute in medical image processing field.
format Thesis
author Rahmat, Muhammad Imran
author_facet Rahmat, Muhammad Imran
author_sort Rahmat, Muhammad Imran
title Automated Hypertensive Retinopathy detection using image processing / Muhammad Imran Rahmat
title_short Automated Hypertensive Retinopathy detection using image processing / Muhammad Imran Rahmat
title_full Automated Hypertensive Retinopathy detection using image processing / Muhammad Imran Rahmat
title_fullStr Automated Hypertensive Retinopathy detection using image processing / Muhammad Imran Rahmat
title_full_unstemmed Automated Hypertensive Retinopathy detection using image processing / Muhammad Imran Rahmat
title_sort automated hypertensive retinopathy detection using image processing / muhammad imran rahmat
publishDate 2020
url http://ir.uitm.edu.my/id/eprint/31492/1/31492.pdf
http://ir.uitm.edu.my/id/eprint/31492/
_version_ 1685650796623953920