The benefits of total harmonic distortion of currents (THDi) reduction in cables of low voltage power distribution system / Mohammad Nizam Ibrahim, Irni Hamiza Hamzah and Linda Mohd Kasim

Harmonic currents are generated by single and three-phase non-linear electronic loads. The usage of non-linear loads increasing rapidly and the quantity of these types of loads are dominant of the power system loads since its have higher efficiency and low cost. However the disadvantage of using the...

Full description

Saved in:
Bibliographic Details
Main Authors: Ibrahim, Mohammad Nizam, Hamzah, Irni Hamiza, Mohd Kasim, Linda
Format: Research Reports
Language:English
Published: 2007
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/39983/1/39983.pdf
http://ir.uitm.edu.my/id/eprint/39983/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Mara
Language: English
id my.uitm.ir.39983
record_format eprints
spelling my.uitm.ir.399832021-01-11T09:43:06Z http://ir.uitm.edu.my/id/eprint/39983/ The benefits of total harmonic distortion of currents (THDi) reduction in cables of low voltage power distribution system / Mohammad Nizam Ibrahim, Irni Hamiza Hamzah and Linda Mohd Kasim Ibrahim, Mohammad Nizam Hamzah, Irni Hamiza Mohd Kasim, Linda Electric power distribution. Electric power transmission Malaysia Harmonic currents are generated by single and three-phase non-linear electronic loads. The usage of non-linear loads increasing rapidly and the quantity of these types of loads are dominant of the power system loads since its have higher efficiency and low cost. However the disadvantage of using the non-linear loads that they are producing harmonic currents that flow back in the power system and affect the power system by adding additional power loss throughout the electrical distribution system. These losses result in apparatus overheating, higher air conditioning costs, reduce the equipment life span and higher power costs. In this paper, the effect of total harmonic distortion of currents (THDi) to the cables power loss of low voltage power distribution system was examined. Hence, the benefits of reduction the THDi and the amount of power loss that could be saved also determined. A laboratory model was developed to experimentally verify the result. Good agreement was obtained between theory and laboratory experiments. 2007-08 Research Reports NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/39983/1/39983.pdf Ibrahim, Mohammad Nizam and Hamzah, Irni Hamiza and Mohd Kasim, Linda (2007) The benefits of total harmonic distortion of currents (THDi) reduction in cables of low voltage power distribution system / Mohammad Nizam Ibrahim, Irni Hamiza Hamzah and Linda Mohd Kasim. [Research Reports] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Electric power distribution. Electric power transmission
Malaysia
spellingShingle Electric power distribution. Electric power transmission
Malaysia
Ibrahim, Mohammad Nizam
Hamzah, Irni Hamiza
Mohd Kasim, Linda
The benefits of total harmonic distortion of currents (THDi) reduction in cables of low voltage power distribution system / Mohammad Nizam Ibrahim, Irni Hamiza Hamzah and Linda Mohd Kasim
description Harmonic currents are generated by single and three-phase non-linear electronic loads. The usage of non-linear loads increasing rapidly and the quantity of these types of loads are dominant of the power system loads since its have higher efficiency and low cost. However the disadvantage of using the non-linear loads that they are producing harmonic currents that flow back in the power system and affect the power system by adding additional power loss throughout the electrical distribution system. These losses result in apparatus overheating, higher air conditioning costs, reduce the equipment life span and higher power costs. In this paper, the effect of total harmonic distortion of currents (THDi) to the cables power loss of low voltage power distribution system was examined. Hence, the benefits of reduction the THDi and the amount of power loss that could be saved also determined. A laboratory model was developed to experimentally verify the result. Good agreement was obtained between theory and laboratory experiments.
format Research Reports
author Ibrahim, Mohammad Nizam
Hamzah, Irni Hamiza
Mohd Kasim, Linda
author_facet Ibrahim, Mohammad Nizam
Hamzah, Irni Hamiza
Mohd Kasim, Linda
author_sort Ibrahim, Mohammad Nizam
title The benefits of total harmonic distortion of currents (THDi) reduction in cables of low voltage power distribution system / Mohammad Nizam Ibrahim, Irni Hamiza Hamzah and Linda Mohd Kasim
title_short The benefits of total harmonic distortion of currents (THDi) reduction in cables of low voltage power distribution system / Mohammad Nizam Ibrahim, Irni Hamiza Hamzah and Linda Mohd Kasim
title_full The benefits of total harmonic distortion of currents (THDi) reduction in cables of low voltage power distribution system / Mohammad Nizam Ibrahim, Irni Hamiza Hamzah and Linda Mohd Kasim
title_fullStr The benefits of total harmonic distortion of currents (THDi) reduction in cables of low voltage power distribution system / Mohammad Nizam Ibrahim, Irni Hamiza Hamzah and Linda Mohd Kasim
title_full_unstemmed The benefits of total harmonic distortion of currents (THDi) reduction in cables of low voltage power distribution system / Mohammad Nizam Ibrahim, Irni Hamiza Hamzah and Linda Mohd Kasim
title_sort benefits of total harmonic distortion of currents (thdi) reduction in cables of low voltage power distribution system / mohammad nizam ibrahim, irni hamiza hamzah and linda mohd kasim
publishDate 2007
url http://ir.uitm.edu.my/id/eprint/39983/1/39983.pdf
http://ir.uitm.edu.my/id/eprint/39983/
_version_ 1690374235157954560