Electronic climate controller / Rizal Mat Jusoh and Hasrul Zaidi Zainol Abidin
Fundamental of Electronic climate controller (ECC) is temperature sensor. This temperature sensor has a temperature coefficient of reverse breakdown voltage equal to + 10 mV /°K , is extrapolated to O mV at 0°K . Thus, at room temperature (298.2(K), the voltage across IC4 (LM 335) should be 298.2 mV...
Saved in:
Main Authors: | , |
---|---|
Format: | Student Project |
Language: | English |
Published: |
2000
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/49007/1/49007.PDF https://ir.uitm.edu.my/id/eprint/49007/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Mara |
Language: | English |
id |
my.uitm.ir.49007 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.490072021-08-03T01:13:52Z https://ir.uitm.edu.my/id/eprint/49007/ Electronic climate controller / Rizal Mat Jusoh and Hasrul Zaidi Zainol Abidin Mat Jusoh, Rizal Zainol Abidin, Hasrul Zaidi Electronics Detectors. Sensors. Sensor networks Microelectromechanical systems Microwaves. Including microwave circuits Applications of electronics Photoelectronic devices (General) Fundamental of Electronic climate controller (ECC) is temperature sensor. This temperature sensor has a temperature coefficient of reverse breakdown voltage equal to + 10 mV /°K , is extrapolated to O mV at 0°K . Thus, at room temperature (298.2(K), the voltage across IC4 (LM 335) should be 298.2 mV X 10 mV /°K = 2.982V. But, in practice it has some error due to self-heating and other related factors (heat sources). These errors are eliminated during the calibration procedure at last activity of construction. The dot/bar display driver IC2 (LM 3914) will drive 10 LEDs to show room temperature, where each of it is marked with certain temperature. Example, LED 1= 67(F and LED 2 = 69(F, if room temperature is 69(F both LEDs will ON. Whenever room temperature reach certain value Relay (RY 1) will switch ON fan or air-condition. The fan will OFF automatically when room temperature is equal with settled temperature on calibration procedure. 2000 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/49007/1/49007.PDF ID49007 Mat Jusoh, Rizal and Zainol Abidin, Hasrul Zaidi (2000) Electronic climate controller / Rizal Mat Jusoh and Hasrul Zaidi Zainol Abidin. [Student Project] (Unpublished) |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Electronics Detectors. Sensors. Sensor networks Microelectromechanical systems Microwaves. Including microwave circuits Applications of electronics Photoelectronic devices (General) |
spellingShingle |
Electronics Detectors. Sensors. Sensor networks Microelectromechanical systems Microwaves. Including microwave circuits Applications of electronics Photoelectronic devices (General) Mat Jusoh, Rizal Zainol Abidin, Hasrul Zaidi Electronic climate controller / Rizal Mat Jusoh and Hasrul Zaidi Zainol Abidin |
description |
Fundamental of Electronic climate controller (ECC) is temperature sensor. This temperature sensor has a temperature coefficient of reverse breakdown voltage equal to + 10 mV /°K , is extrapolated to O mV at 0°K . Thus, at room temperature (298.2(K), the voltage across IC4 (LM 335) should be 298.2 mV X 10 mV /°K = 2.982V. But, in practice it has some error due to self-heating and other related factors (heat sources). These errors are eliminated during the calibration procedure at last activity of construction. The dot/bar display driver IC2 (LM 3914) will drive 10 LEDs to show room temperature, where each of it is marked with certain temperature. Example, LED 1= 67(F and LED 2 = 69(F, if room temperature is 69(F both LEDs will ON. Whenever room temperature reach certain value Relay (RY 1) will switch ON fan or air-condition. The fan will OFF automatically when room temperature is equal with settled temperature on calibration procedure. |
format |
Student Project |
author |
Mat Jusoh, Rizal Zainol Abidin, Hasrul Zaidi |
author_facet |
Mat Jusoh, Rizal Zainol Abidin, Hasrul Zaidi |
author_sort |
Mat Jusoh, Rizal |
title |
Electronic climate controller / Rizal Mat Jusoh and Hasrul Zaidi Zainol Abidin |
title_short |
Electronic climate controller / Rizal Mat Jusoh and Hasrul Zaidi Zainol Abidin |
title_full |
Electronic climate controller / Rizal Mat Jusoh and Hasrul Zaidi Zainol Abidin |
title_fullStr |
Electronic climate controller / Rizal Mat Jusoh and Hasrul Zaidi Zainol Abidin |
title_full_unstemmed |
Electronic climate controller / Rizal Mat Jusoh and Hasrul Zaidi Zainol Abidin |
title_sort |
electronic climate controller / rizal mat jusoh and hasrul zaidi zainol abidin |
publishDate |
2000 |
url |
https://ir.uitm.edu.my/id/eprint/49007/1/49007.PDF https://ir.uitm.edu.my/id/eprint/49007/ |
_version_ |
1707768624418127872 |