Effect of intraoral digital sensor colour variation and connection cable position on discomfort level in periapical (PA) radiography technique / Shahrani Janudin, Harith Fadhilah Halim, Zanariah Mohd

Peripical (PA) technique is one of the intraoral radiography techniques that requires the image receptor such as film and sensor to be inserted into the oral cavity. This may lead to discomfort especially with the use of current digital sensor. Current design by most of the vendors highlighted the n...

Full description

Saved in:
Bibliographic Details
Main Authors: Janudin, Shahrani, Halim, Harith Fadhilah, Zanariah, Mohd
Format: Article
Language:English
Published: Faculty of Health Sciences, Universiti Teknologi MARA 2019
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/54725/1/54725.pdf
https://ir.uitm.edu.my/id/eprint/54725/
http://healthscopefsk.com/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Mara
Language: English
id my.uitm.ir.54725
record_format eprints
spelling my.uitm.ir.547252021-12-30T00:04:18Z https://ir.uitm.edu.my/id/eprint/54725/ Effect of intraoral digital sensor colour variation and connection cable position on discomfort level in periapical (PA) radiography technique / Shahrani Janudin, Harith Fadhilah Halim, Zanariah Mohd Janudin, Shahrani Halim, Harith Fadhilah Zanariah, Mohd Examination. Diagnosis. Including radiography Peripical (PA) technique is one of the intraoral radiography techniques that requires the image receptor such as film and sensor to be inserted into the oral cavity. This may lead to discomfort especially with the use of current digital sensor. Current design by most of the vendors highlighted the need of ergonomic shape and optimum thickness to minimize the discomfort. This study evaluated the effect of sensor’s colours and cable position on discomfort feeling during PA. An experimental approach using pre and post intervention technique to evaluate the respondents’ feedback with the use of the sensors was conducted. A total number of 47 respondents were selected from Faculty of Health Sciences, Universiti Teknologi MARA (UiTM) via systematic random sampling. The respondents experienced different design of digital intraoral sensor during the simulation of PA dental radiography procedure for posterior teeth. A Numeric Rating Scale (NRS) scoring were adopted to assess and compare any discomfort experienced by the respondents. The descriptive analysis showed that median NRS score value was higher for dark blue colour sensor (median = 8) as compared to the black sensor (median=7). The Wilcoxon matched paired sign rank test showed that there was a significant difference in terms of the discomfort level experienced by the respondents (p < 0.001). For the cable connection design, the median score value of corner position is greater recorded as 7, than the cable connection position at the centre which the median is 6. Cable connection position at the centre was less discomfort as compared to cable connection located at the corner of the sensor. As conclusion, the colour and cable connection location could affect the discomfort level during PA radiography technique. Faculty of Health Sciences, Universiti Teknologi MARA 2019-06 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/54725/1/54725.pdf ID54725 Janudin, Shahrani and Halim, Harith Fadhilah and Zanariah, Mohd (2019) Effect of intraoral digital sensor colour variation and connection cable position on discomfort level in periapical (PA) radiography technique / Shahrani Janudin, Harith Fadhilah Halim, Zanariah Mohd. Health Scope, 1. pp. 120-124. ISSN 2735-0649 http://healthscopefsk.com/
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Examination. Diagnosis. Including radiography
spellingShingle Examination. Diagnosis. Including radiography
Janudin, Shahrani
Halim, Harith Fadhilah
Zanariah, Mohd
Effect of intraoral digital sensor colour variation and connection cable position on discomfort level in periapical (PA) radiography technique / Shahrani Janudin, Harith Fadhilah Halim, Zanariah Mohd
description Peripical (PA) technique is one of the intraoral radiography techniques that requires the image receptor such as film and sensor to be inserted into the oral cavity. This may lead to discomfort especially with the use of current digital sensor. Current design by most of the vendors highlighted the need of ergonomic shape and optimum thickness to minimize the discomfort. This study evaluated the effect of sensor’s colours and cable position on discomfort feeling during PA. An experimental approach using pre and post intervention technique to evaluate the respondents’ feedback with the use of the sensors was conducted. A total number of 47 respondents were selected from Faculty of Health Sciences, Universiti Teknologi MARA (UiTM) via systematic random sampling. The respondents experienced different design of digital intraoral sensor during the simulation of PA dental radiography procedure for posterior teeth. A Numeric Rating Scale (NRS) scoring were adopted to assess and compare any discomfort experienced by the respondents. The descriptive analysis showed that median NRS score value was higher for dark blue colour sensor (median = 8) as compared to the black sensor (median=7). The Wilcoxon matched paired sign rank test showed that there was a significant difference in terms of the discomfort level experienced by the respondents (p < 0.001). For the cable connection design, the median score value of corner position is greater recorded as 7, than the cable connection position at the centre which the median is 6. Cable connection position at the centre was less discomfort as compared to cable connection located at the corner of the sensor. As conclusion, the colour and cable connection location could affect the discomfort level during PA radiography technique.
format Article
author Janudin, Shahrani
Halim, Harith Fadhilah
Zanariah, Mohd
author_facet Janudin, Shahrani
Halim, Harith Fadhilah
Zanariah, Mohd
author_sort Janudin, Shahrani
title Effect of intraoral digital sensor colour variation and connection cable position on discomfort level in periapical (PA) radiography technique / Shahrani Janudin, Harith Fadhilah Halim, Zanariah Mohd
title_short Effect of intraoral digital sensor colour variation and connection cable position on discomfort level in periapical (PA) radiography technique / Shahrani Janudin, Harith Fadhilah Halim, Zanariah Mohd
title_full Effect of intraoral digital sensor colour variation and connection cable position on discomfort level in periapical (PA) radiography technique / Shahrani Janudin, Harith Fadhilah Halim, Zanariah Mohd
title_fullStr Effect of intraoral digital sensor colour variation and connection cable position on discomfort level in periapical (PA) radiography technique / Shahrani Janudin, Harith Fadhilah Halim, Zanariah Mohd
title_full_unstemmed Effect of intraoral digital sensor colour variation and connection cable position on discomfort level in periapical (PA) radiography technique / Shahrani Janudin, Harith Fadhilah Halim, Zanariah Mohd
title_sort effect of intraoral digital sensor colour variation and connection cable position on discomfort level in periapical (pa) radiography technique / shahrani janudin, harith fadhilah halim, zanariah mohd
publisher Faculty of Health Sciences, Universiti Teknologi MARA
publishDate 2019
url https://ir.uitm.edu.my/id/eprint/54725/1/54725.pdf
https://ir.uitm.edu.my/id/eprint/54725/
http://healthscopefsk.com/
_version_ 1720983250075123712