Determination of nominal operating cell temperature for photovoltaic modules in tropical Malaysia / Muhamad Mukhzani Muhamad Hanifah

Photovoltaic (PV) modules are sent by manufacturers for testing to numerous testing laboratories in the world particularly the renowned ones to get international certifications. One of the tests is Nominal Operating Cell Temperature (NOCT) determination which will act as thermal characteristics of a...

Full description

Saved in:
Bibliographic Details
Main Author: Muhamad Hanifah, Muhamad Mukhzani
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/59080/1/59080.pdf
https://ir.uitm.edu.my/id/eprint/59080/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Mara
Language: English
id my.uitm.ir.59080
record_format eprints
spelling my.uitm.ir.590802022-04-29T03:13:20Z https://ir.uitm.edu.my/id/eprint/59080/ Determination of nominal operating cell temperature for photovoltaic modules in tropical Malaysia / Muhamad Mukhzani Muhamad Hanifah Muhamad Hanifah, Muhamad Mukhzani Descriptive and experimental mechanics Temperature Photovoltaic (PV) modules are sent by manufacturers for testing to numerous testing laboratories in the world particularly the renowned ones to get international certifications. One of the tests is Nominal Operating Cell Temperature (NOCT) determination which will act as thermal characteristics of a specific design of PV module under actual outdoor condition. However, the present specified outdoor test conditions designated as Standard Reference Environment (SRE) in IEC61215 is not possible in tropical Malaysia as ambient temperature of 20 °C is not achievable. New modified SRE is needed for an NOCT test to be conducted in Malaysia and will consequently formulate new NOCT mathematical model. Numerous studies have been conducted in investigating SRE in NOCT testing and consequently NOCT values. Nevertheless, very few studies were conducted under tropical region particularly Malaysia. This study presented the evaluation of SRE ambient parameters of solar irradiance (SI), ambient temperature (AT) and wind speed (WS), developed and verified a new SRE, developed and verified new revised NOCT model which finally determined the NOCT values for monocrystalline, polycrystalline and copper indium selenium thin film PV modules under tropical Malaysia climate condition. This was achieved through field testing and meticulous analytical techniques of statistical and mathematical. One year field data of five minutes interval was analysed for SRE evaluation and development, meanwhile a month field data of five seconds interval was analysed for NOCT testing. All testing procedures and equipment specifications were based on international standard of IEC 61215, IEC 61646 and IEC 61724. The SRE ambient parameters of SI, AT and WS median were found to be 294 W/m2, 31°C and 1 m/s respectively. The median SI was very much lower than the current SI of 800 W/m2 stated in the IEC standard. Thus, a new SRE was developed for NOCT testing dedicated for tropical Malaysia by acquiring the corresponding value of AT at SI of 800 W/m2. As a result, the new developed SRE ambient parameters that suits tropical Malaysia are SI of 800 W/m2, AT of 31°C and WS of 1 m/s. Modifying the existing SRE consequently formulated new NOCT model. The accuracy of the modified NOCT model has outperformed the existing NOCT model by 2 % on average via percentage error, root mean square error and mean average percentage error analysis. Finally, the NOCT values of monocrystalline, polycrystalline and thin film PV modules are 55 oC, 57 oC and 59 oC respectively. Thus, this study has succeeded in determining NOCT values for tropical Malaysia which are significantly higher than the value of present NOCT. Results of this study can provide significant input to IEC 61215 and IEC 61646 committee to address revision and modification of SRE and NOCT model. Furthermore, the NOCT values obtained will be an outdoor thermal reference that can be 2020-08 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/59080/1/59080.pdf (2020) Determination of nominal operating cell temperature for photovoltaic modules in tropical Malaysia / Muhamad Mukhzani Muhamad Hanifah. Masters thesis, thesis, Universiti Teknologi MARA.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Descriptive and experimental mechanics
Temperature
spellingShingle Descriptive and experimental mechanics
Temperature
Muhamad Hanifah, Muhamad Mukhzani
Determination of nominal operating cell temperature for photovoltaic modules in tropical Malaysia / Muhamad Mukhzani Muhamad Hanifah
description Photovoltaic (PV) modules are sent by manufacturers for testing to numerous testing laboratories in the world particularly the renowned ones to get international certifications. One of the tests is Nominal Operating Cell Temperature (NOCT) determination which will act as thermal characteristics of a specific design of PV module under actual outdoor condition. However, the present specified outdoor test conditions designated as Standard Reference Environment (SRE) in IEC61215 is not possible in tropical Malaysia as ambient temperature of 20 °C is not achievable. New modified SRE is needed for an NOCT test to be conducted in Malaysia and will consequently formulate new NOCT mathematical model. Numerous studies have been conducted in investigating SRE in NOCT testing and consequently NOCT values. Nevertheless, very few studies were conducted under tropical region particularly Malaysia. This study presented the evaluation of SRE ambient parameters of solar irradiance (SI), ambient temperature (AT) and wind speed (WS), developed and verified a new SRE, developed and verified new revised NOCT model which finally determined the NOCT values for monocrystalline, polycrystalline and copper indium selenium thin film PV modules under tropical Malaysia climate condition. This was achieved through field testing and meticulous analytical techniques of statistical and mathematical. One year field data of five minutes interval was analysed for SRE evaluation and development, meanwhile a month field data of five seconds interval was analysed for NOCT testing. All testing procedures and equipment specifications were based on international standard of IEC 61215, IEC 61646 and IEC 61724. The SRE ambient parameters of SI, AT and WS median were found to be 294 W/m2, 31°C and 1 m/s respectively. The median SI was very much lower than the current SI of 800 W/m2 stated in the IEC standard. Thus, a new SRE was developed for NOCT testing dedicated for tropical Malaysia by acquiring the corresponding value of AT at SI of 800 W/m2. As a result, the new developed SRE ambient parameters that suits tropical Malaysia are SI of 800 W/m2, AT of 31°C and WS of 1 m/s. Modifying the existing SRE consequently formulated new NOCT model. The accuracy of the modified NOCT model has outperformed the existing NOCT model by 2 % on average via percentage error, root mean square error and mean average percentage error analysis. Finally, the NOCT values of monocrystalline, polycrystalline and thin film PV modules are 55 oC, 57 oC and 59 oC respectively. Thus, this study has succeeded in determining NOCT values for tropical Malaysia which are significantly higher than the value of present NOCT. Results of this study can provide significant input to IEC 61215 and IEC 61646 committee to address revision and modification of SRE and NOCT model. Furthermore, the NOCT values obtained will be an outdoor thermal reference that can be
format Thesis
author Muhamad Hanifah, Muhamad Mukhzani
author_facet Muhamad Hanifah, Muhamad Mukhzani
author_sort Muhamad Hanifah, Muhamad Mukhzani
title Determination of nominal operating cell temperature for photovoltaic modules in tropical Malaysia / Muhamad Mukhzani Muhamad Hanifah
title_short Determination of nominal operating cell temperature for photovoltaic modules in tropical Malaysia / Muhamad Mukhzani Muhamad Hanifah
title_full Determination of nominal operating cell temperature for photovoltaic modules in tropical Malaysia / Muhamad Mukhzani Muhamad Hanifah
title_fullStr Determination of nominal operating cell temperature for photovoltaic modules in tropical Malaysia / Muhamad Mukhzani Muhamad Hanifah
title_full_unstemmed Determination of nominal operating cell temperature for photovoltaic modules in tropical Malaysia / Muhamad Mukhzani Muhamad Hanifah
title_sort determination of nominal operating cell temperature for photovoltaic modules in tropical malaysia / muhamad mukhzani muhamad hanifah
publishDate 2020
url https://ir.uitm.edu.my/id/eprint/59080/1/59080.pdf
https://ir.uitm.edu.my/id/eprint/59080/
_version_ 1732948382952980480