Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin
Many enhancements were made to timber in order to ensure its continuous application and commercialization. Glulam is designated as structural member with crucial attention needed to its jointing system. Similar to other large structural system the weakest point of glulam elements is the connections....
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2020
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/61026/1/61026.pdf https://ir.uitm.edu.my/id/eprint/61026/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Mara |
Language: | English |
id |
my.uitm.ir.61026 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.610262022-06-07T06:07:54Z https://ir.uitm.edu.my/id/eprint/61026/ Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin Raja Hussin, Tengku Anita Timber. Wood Many enhancements were made to timber in order to ensure its continuous application and commercialization. Glulam is designated as structural member with crucial attention needed to its jointing system. Similar to other large structural system the weakest point of glulam elements is the connections. Incomplete and limited information on guideline for tropical glulam design for glued-in rod has contributed to a set back of the Malaysian timber as the structural member. Due to this limitation, the standard design for glued-in rod using glulam is basically referred to the estimated extrapolation for solid timber guidelines. Therefore, the main objectives of glued-in rods for pull-out splice (GRPS) are to investigate the pull-out performance of glued-in rods connections using the most common species, Mengkulang glulam (strength group 5) for timber splice joints. The method is by determining shear strength of the glued-in steel rod for Mengkulang species and the types of failure modes were observed. The experimental were the tensile load carrying capacity for glued-in rod in glulam splice joints, to investigate the physical and mechanical properties of glulam with different diameters of rod, glue-line thickness and grain direction. 2020-09 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/61026/1/61026.pdf Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin. (2020) PhD thesis, thesis, Universiti Teknologi MARA. |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Timber. Wood |
spellingShingle |
Timber. Wood Raja Hussin, Tengku Anita Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin |
description |
Many enhancements were made to timber in order to ensure its continuous application and commercialization. Glulam is designated as structural member with crucial attention needed to its jointing system. Similar to other large structural system the weakest point of glulam elements is the connections. Incomplete and limited information on guideline for tropical glulam design for glued-in rod has contributed to a set back of the Malaysian timber as the structural member. Due to this limitation, the standard design for glued-in rod using glulam is basically referred to the estimated extrapolation for solid timber guidelines. Therefore, the main objectives of glued-in rods for pull-out splice (GRPS) are to investigate the pull-out performance of glued-in rods connections using the most common species, Mengkulang glulam (strength group 5) for timber splice joints. The method is by determining shear strength of the glued-in steel rod for Mengkulang species and the types of failure modes were observed. The experimental were the tensile load carrying capacity for glued-in rod in glulam splice joints, to investigate the physical and mechanical properties of glulam with different diameters of rod, glue-line thickness and grain direction. |
format |
Thesis |
author |
Raja Hussin, Tengku Anita |
author_facet |
Raja Hussin, Tengku Anita |
author_sort |
Raja Hussin, Tengku Anita |
title |
Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin |
title_short |
Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin |
title_full |
Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin |
title_fullStr |
Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin |
title_full_unstemmed |
Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin |
title_sort |
structural performance of glued-in rods for pull-out splice (grps) timber connections made of mengkulang glulam / tengku anita raja hussin |
publishDate |
2020 |
url |
https://ir.uitm.edu.my/id/eprint/61026/1/61026.pdf https://ir.uitm.edu.my/id/eprint/61026/ |
_version_ |
1735389677807992832 |