Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin

Many enhancements were made to timber in order to ensure its continuous application and commercialization. Glulam is designated as structural member with crucial attention needed to its jointing system. Similar to other large structural system the weakest point of glulam elements is the connections....

Full description

Saved in:
Bibliographic Details
Main Author: Raja Hussin, Tengku Anita
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/61026/1/61026.pdf
https://ir.uitm.edu.my/id/eprint/61026/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Mara
Language: English
id my.uitm.ir.61026
record_format eprints
spelling my.uitm.ir.610262022-06-07T06:07:54Z https://ir.uitm.edu.my/id/eprint/61026/ Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin Raja Hussin, Tengku Anita Timber. Wood Many enhancements were made to timber in order to ensure its continuous application and commercialization. Glulam is designated as structural member with crucial attention needed to its jointing system. Similar to other large structural system the weakest point of glulam elements is the connections. Incomplete and limited information on guideline for tropical glulam design for glued-in rod has contributed to a set back of the Malaysian timber as the structural member. Due to this limitation, the standard design for glued-in rod using glulam is basically referred to the estimated extrapolation for solid timber guidelines. Therefore, the main objectives of glued-in rods for pull-out splice (GRPS) are to investigate the pull-out performance of glued-in rods connections using the most common species, Mengkulang glulam (strength group 5) for timber splice joints. The method is by determining shear strength of the glued-in steel rod for Mengkulang species and the types of failure modes were observed. The experimental were the tensile load carrying capacity for glued-in rod in glulam splice joints, to investigate the physical and mechanical properties of glulam with different diameters of rod, glue-line thickness and grain direction. 2020-09 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/61026/1/61026.pdf Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin. (2020) PhD thesis, thesis, Universiti Teknologi MARA.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Timber. Wood
spellingShingle Timber. Wood
Raja Hussin, Tengku Anita
Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin
description Many enhancements were made to timber in order to ensure its continuous application and commercialization. Glulam is designated as structural member with crucial attention needed to its jointing system. Similar to other large structural system the weakest point of glulam elements is the connections. Incomplete and limited information on guideline for tropical glulam design for glued-in rod has contributed to a set back of the Malaysian timber as the structural member. Due to this limitation, the standard design for glued-in rod using glulam is basically referred to the estimated extrapolation for solid timber guidelines. Therefore, the main objectives of glued-in rods for pull-out splice (GRPS) are to investigate the pull-out performance of glued-in rods connections using the most common species, Mengkulang glulam (strength group 5) for timber splice joints. The method is by determining shear strength of the glued-in steel rod for Mengkulang species and the types of failure modes were observed. The experimental were the tensile load carrying capacity for glued-in rod in glulam splice joints, to investigate the physical and mechanical properties of glulam with different diameters of rod, glue-line thickness and grain direction.
format Thesis
author Raja Hussin, Tengku Anita
author_facet Raja Hussin, Tengku Anita
author_sort Raja Hussin, Tengku Anita
title Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin
title_short Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin
title_full Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin
title_fullStr Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin
title_full_unstemmed Structural performance of glued-in rods for pull-out splice (GRPS) timber connections made of Mengkulang glulam / Tengku Anita Raja Hussin
title_sort structural performance of glued-in rods for pull-out splice (grps) timber connections made of mengkulang glulam / tengku anita raja hussin
publishDate 2020
url https://ir.uitm.edu.my/id/eprint/61026/1/61026.pdf
https://ir.uitm.edu.my/id/eprint/61026/
_version_ 1735389677807992832