Heat detector alarm system / Sharifah Norziah Sayed Mohamed Zain, Siti Norshahirah Abdullah and Siti Nur Anis Zakaria
This project is designed to notify the building occupant to evacuate to the safer area as soon as fire detected which call the heat detector alarm system. This heat detector alarm system has three subsystems which are the detecting system, warning system and controlling system. The overall system of...
Saved in:
Main Authors: | , , |
---|---|
Format: | Student Project |
Language: | English |
Published: |
2015
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/61522/1/61522.pdf https://ir.uitm.edu.my/id/eprint/61522/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Mara |
Language: | English |
id |
my.uitm.ir.61522 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.615222022-06-20T04:57:44Z https://ir.uitm.edu.my/id/eprint/61522/ Heat detector alarm system / Sharifah Norziah Sayed Mohamed Zain, Siti Norshahirah Abdullah and Siti Nur Anis Zakaria Sayed Mohamed Zain, Sharifah Norziah Abdullah, Siti Norshahirah Zakaria, Siti Nur Anis Information technology. Information systems TK Electrical engineering. Electronics. Nuclear engineering Electric heating. Resistance heating Electronics Detectors. Sensors. Sensor networks This project is designed to notify the building occupant to evacuate to the safer area as soon as fire detected which call the heat detector alarm system. This heat detector alarm system has three subsystems which are the detecting system, warning system and controlling system. The overall system of heat detector alarm system is controlled by the Arduino. The detection system operates as the fire detector. In this detection system, LM35 acts as the main sensor which is to detect the surrounding temperature. The sensor is placed at the control room in the building and the LCD used to display the current temperature and the current condition. The buzzer is in the warning system while the water sprinkler motor for the controlling system. Once the detected temperature above than 45°C, the buzzer and the LED act as the guide path to the safer area will on simultaneously while the water motor will active after ten second the LED and buzzer on 2015-03 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/61522/1/61522.pdf Heat detector alarm system / Sharifah Norziah Sayed Mohamed Zain, Siti Norshahirah Abdullah and Siti Nur Anis Zakaria. (2015) [Student Project] (Submitted) |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Information technology. Information systems TK Electrical engineering. Electronics. Nuclear engineering Electric heating. Resistance heating Electronics Detectors. Sensors. Sensor networks |
spellingShingle |
Information technology. Information systems TK Electrical engineering. Electronics. Nuclear engineering Electric heating. Resistance heating Electronics Detectors. Sensors. Sensor networks Sayed Mohamed Zain, Sharifah Norziah Abdullah, Siti Norshahirah Zakaria, Siti Nur Anis Heat detector alarm system / Sharifah Norziah Sayed Mohamed Zain, Siti Norshahirah Abdullah and Siti Nur Anis Zakaria |
description |
This project is designed to notify the building occupant to evacuate to the safer area as soon as fire detected which call the heat detector alarm system. This heat detector alarm system has three subsystems which are the detecting system, warning system and controlling system. The overall system of heat detector alarm system is controlled by the Arduino. The detection system operates as the fire detector. In this detection system, LM35 acts as the main sensor which is to detect the surrounding temperature. The sensor is placed at the control room in the building and the LCD used to display the current temperature and the current condition. The buzzer is in the warning system while the water sprinkler motor for the controlling system. Once the detected temperature above than 45°C, the buzzer and the LED act as the guide path to the safer area will on simultaneously while the water motor will active after ten second the LED and buzzer on |
format |
Student Project |
author |
Sayed Mohamed Zain, Sharifah Norziah Abdullah, Siti Norshahirah Zakaria, Siti Nur Anis |
author_facet |
Sayed Mohamed Zain, Sharifah Norziah Abdullah, Siti Norshahirah Zakaria, Siti Nur Anis |
author_sort |
Sayed Mohamed Zain, Sharifah Norziah |
title |
Heat detector alarm system / Sharifah Norziah Sayed Mohamed Zain, Siti Norshahirah Abdullah and Siti Nur Anis Zakaria |
title_short |
Heat detector alarm system / Sharifah Norziah Sayed Mohamed Zain, Siti Norshahirah Abdullah and Siti Nur Anis Zakaria |
title_full |
Heat detector alarm system / Sharifah Norziah Sayed Mohamed Zain, Siti Norshahirah Abdullah and Siti Nur Anis Zakaria |
title_fullStr |
Heat detector alarm system / Sharifah Norziah Sayed Mohamed Zain, Siti Norshahirah Abdullah and Siti Nur Anis Zakaria |
title_full_unstemmed |
Heat detector alarm system / Sharifah Norziah Sayed Mohamed Zain, Siti Norshahirah Abdullah and Siti Nur Anis Zakaria |
title_sort |
heat detector alarm system / sharifah norziah sayed mohamed zain, siti norshahirah abdullah and siti nur anis zakaria |
publishDate |
2015 |
url |
https://ir.uitm.edu.my/id/eprint/61522/1/61522.pdf https://ir.uitm.edu.my/id/eprint/61522/ |
_version_ |
1736837342365220864 |