Analytical method for determining axial-flux permanent-magnet machine sensitivity to design variables

This paper presents an analytical approach to determining sensitivity of a slotted axial-flux permanent-magnet machine to its design variables The method is modeled on a simple nonlinear magnetic analysis of an equivalent magnetic circuit with a saturation-possible magnetic-reluctance core in a slot...

Full description

Saved in:
Bibliographic Details
Main Authors: Mahmoudi, A., Rahim, N.A., Hew, W.P.
Format: Article
Published: Praise Worthy Prize 2010
Subjects:
Online Access:http://eprints.um.edu.my/12446/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.12446
record_format eprints
spelling my.um.eprints.124462019-08-09T01:34:16Z http://eprints.um.edu.my/12446/ Analytical method for determining axial-flux permanent-magnet machine sensitivity to design variables Mahmoudi, A. Rahim, N.A. Hew, W.P. Q Science (General) This paper presents an analytical approach to determining sensitivity of a slotted axial-flux permanent-magnet machine to its design variables The method is modeled on a simple nonlinear magnetic analysis of an equivalent magnetic circuit with a saturation-possible magnetic-reluctance core in a slotted axial-flux permanent-magnet machine It calculates flux distribution and torque characteristic in various operating conditions Its accuracy and validity are verified by results that match those of a Finite Element Analysis model The method is as accurate as FEA but betters FEA with its shorter computation time making it the better alternative in initial estimations and in expediting design optimization of electrical machines Design parameters for maximum output torque and efficiency iteratively adjusted through multi-objective optimal design are selected via sensitivity analysis of the proposed magnetic circuit Simulation results show AFPM machine efficiency to be affected the most by its diameter, followed by magnet fraction and the least by back-iron thickness Copyright (C) 2010 Praise Worthy Prize S r l. - All rights reserved. Praise Worthy Prize 2010 Article PeerReviewed Mahmoudi, A. and Rahim, N.A. and Hew, W.P. (2010) Analytical method for determining axial-flux permanent-magnet machine sensitivity to design variables. International Review of Electrical Engineering, 5 (5, A). pp. 2039-2048. ISSN 1827-6660
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Q Science (General)
spellingShingle Q Science (General)
Mahmoudi, A.
Rahim, N.A.
Hew, W.P.
Analytical method for determining axial-flux permanent-magnet machine sensitivity to design variables
description This paper presents an analytical approach to determining sensitivity of a slotted axial-flux permanent-magnet machine to its design variables The method is modeled on a simple nonlinear magnetic analysis of an equivalent magnetic circuit with a saturation-possible magnetic-reluctance core in a slotted axial-flux permanent-magnet machine It calculates flux distribution and torque characteristic in various operating conditions Its accuracy and validity are verified by results that match those of a Finite Element Analysis model The method is as accurate as FEA but betters FEA with its shorter computation time making it the better alternative in initial estimations and in expediting design optimization of electrical machines Design parameters for maximum output torque and efficiency iteratively adjusted through multi-objective optimal design are selected via sensitivity analysis of the proposed magnetic circuit Simulation results show AFPM machine efficiency to be affected the most by its diameter, followed by magnet fraction and the least by back-iron thickness Copyright (C) 2010 Praise Worthy Prize S r l. - All rights reserved.
format Article
author Mahmoudi, A.
Rahim, N.A.
Hew, W.P.
author_facet Mahmoudi, A.
Rahim, N.A.
Hew, W.P.
author_sort Mahmoudi, A.
title Analytical method for determining axial-flux permanent-magnet machine sensitivity to design variables
title_short Analytical method for determining axial-flux permanent-magnet machine sensitivity to design variables
title_full Analytical method for determining axial-flux permanent-magnet machine sensitivity to design variables
title_fullStr Analytical method for determining axial-flux permanent-magnet machine sensitivity to design variables
title_full_unstemmed Analytical method for determining axial-flux permanent-magnet machine sensitivity to design variables
title_sort analytical method for determining axial-flux permanent-magnet machine sensitivity to design variables
publisher Praise Worthy Prize
publishDate 2010
url http://eprints.um.edu.my/12446/
_version_ 1643689299672039424