Field analysis of indoor air quality in high rise and low rise green offices with radiant slab cooling systems in Malaysia

Even though the green building concept is fairly new in Malaysia, the development of this industry has been growing in recent years prior to the launch of Malaysia's own standard, namely the Green Building Index (GBI). One of the criteria assessed in the GBI is the energy efficiency, which take...

Full description

Saved in:
Bibliographic Details
Main Authors: Yau, Yat Huang, Hasbi, S.
Format: Article
Language:English
Published: SAGE Publications 2015
Subjects:
Online Access:http://eprints.um.edu.my/13809/1/Field_analysis_of_indoor_air_quality_in_high_rise_and_low_rise_green.pdf
http://eprints.um.edu.my/13809/
http://ibe.sagepub.com/content/24/2/174.full.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
Language: English
id my.um.eprints.13809
record_format eprints
spelling my.um.eprints.138092019-07-31T01:11:20Z http://eprints.um.edu.my/13809/ Field analysis of indoor air quality in high rise and low rise green offices with radiant slab cooling systems in Malaysia Yau, Yat Huang Hasbi, S. T Technology (General) TJ Mechanical engineering and machinery Even though the green building concept is fairly new in Malaysia, the development of this industry has been growing in recent years prior to the launch of Malaysia's own standard, namely the Green Building Index (GBI). One of the criteria assessed in the GBI is the energy efficiency, which takes about 21 of the overall assessment. Considering this, the passive design has been included in the green building concept to reduce the energy usage without compromising occupant thermal comfort. This study attempts to assess the passive design effectiveness in terms of indoor air quality in green office buildings in the tropics. Two green office buildings that incorporated the radiant slab cooling and conventional cooling system have been selected as case studies. A detailed assessment in terms of thermal comfort parameters (temperature and relative humidity), indoor pollutants' concentration (carbon dioxide, carbon monoxide and formaldehyde) and air movement was carried out. The results showed that the thermal comfort parameters fall within the Malaysian Standard (MS1525:2007) and ASHRAE Standard-55 2010 except for the air movement in both buildings. Based on the results obtained, future buildings using the radiant slab cooling can have a better comfort level from the lesson learned from both buildings. SAGE Publications 2015-04 Article PeerReviewed application/pdf en http://eprints.um.edu.my/13809/1/Field_analysis_of_indoor_air_quality_in_high_rise_and_low_rise_green.pdf Yau, Yat Huang and Hasbi, S. (2015) Field analysis of indoor air quality in high rise and low rise green offices with radiant slab cooling systems in Malaysia. Indoor and Built Environment, 24 (2). pp. 174-184. ISSN 1420-326X http://ibe.sagepub.com/content/24/2/174.full.pdf doi:10.1177/1420326x13506130
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
language English
topic T Technology (General)
TJ Mechanical engineering and machinery
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
Yau, Yat Huang
Hasbi, S.
Field analysis of indoor air quality in high rise and low rise green offices with radiant slab cooling systems in Malaysia
description Even though the green building concept is fairly new in Malaysia, the development of this industry has been growing in recent years prior to the launch of Malaysia's own standard, namely the Green Building Index (GBI). One of the criteria assessed in the GBI is the energy efficiency, which takes about 21 of the overall assessment. Considering this, the passive design has been included in the green building concept to reduce the energy usage without compromising occupant thermal comfort. This study attempts to assess the passive design effectiveness in terms of indoor air quality in green office buildings in the tropics. Two green office buildings that incorporated the radiant slab cooling and conventional cooling system have been selected as case studies. A detailed assessment in terms of thermal comfort parameters (temperature and relative humidity), indoor pollutants' concentration (carbon dioxide, carbon monoxide and formaldehyde) and air movement was carried out. The results showed that the thermal comfort parameters fall within the Malaysian Standard (MS1525:2007) and ASHRAE Standard-55 2010 except for the air movement in both buildings. Based on the results obtained, future buildings using the radiant slab cooling can have a better comfort level from the lesson learned from both buildings.
format Article
author Yau, Yat Huang
Hasbi, S.
author_facet Yau, Yat Huang
Hasbi, S.
author_sort Yau, Yat Huang
title Field analysis of indoor air quality in high rise and low rise green offices with radiant slab cooling systems in Malaysia
title_short Field analysis of indoor air quality in high rise and low rise green offices with radiant slab cooling systems in Malaysia
title_full Field analysis of indoor air quality in high rise and low rise green offices with radiant slab cooling systems in Malaysia
title_fullStr Field analysis of indoor air quality in high rise and low rise green offices with radiant slab cooling systems in Malaysia
title_full_unstemmed Field analysis of indoor air quality in high rise and low rise green offices with radiant slab cooling systems in Malaysia
title_sort field analysis of indoor air quality in high rise and low rise green offices with radiant slab cooling systems in malaysia
publisher SAGE Publications
publishDate 2015
url http://eprints.um.edu.my/13809/1/Field_analysis_of_indoor_air_quality_in_high_rise_and_low_rise_green.pdf
http://eprints.um.edu.my/13809/
http://ibe.sagepub.com/content/24/2/174.full.pdf
_version_ 1643689655399350272