Highly sensitive and selective immunosensors that can detect disease biomarkers at ultra-low levels in early stages are urgently needed to reduce mortality risks. A facile and efficient approach using sonochemical-assisted solvent graphene exfoliation and a hydrothermal synthesis method has been use...

Full description

Saved in:
Bibliographic Details
Main Authors: Siew, Qi Yan, Tham, Shiau Ying, Loh, Hwei San, Khiew, Poi Sim, Chiu, Wee Siong, Tan, Michelle T.T.
Format: Article
Published: Royal Society of Chemistry 2018
Subjects:
Online Access:http://eprints.um.edu.my/20663/
https://doi.org/10.1039/c7tb02891a
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.20663
record_format eprints
spelling my.um.eprints.206632019-03-12T02:31:01Z http://eprints.um.edu.my/20663/ One-step green hydrothermal synthesis of biocompatible graphene/TiO2 nanocomposites for non-enzymatic H2O2 detection and their cytotoxicity effects on human keratinocyte and lung fibroblast cells Siew, Qi Yan Tham, Shiau Ying Loh, Hwei San Khiew, Poi Sim Chiu, Wee Siong Tan, Michelle T.T. Q Science (General) QC Physics Highly sensitive and selective immunosensors that can detect disease biomarkers at ultra-low levels in early stages are urgently needed to reduce mortality risks. A facile and efficient approach using sonochemical-assisted solvent graphene exfoliation and a hydrothermal synthesis method has been used to prepare graphene/titanium dioxide (G/TiO2) nanocomposites. Nanocomposites containing different ratios of graphene and TiO2 precursors were prepared to determine the optimum composition of G/TiO2 that has the highest conductivity and electrocatalytic properties. Characterisation methods such as X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), transmission electron microscopy (TEM), and high resolution TEM (HRTEM) were used to study the crystallinity, surface characteristics, elemental composition, and morphology of the synthesised nanocomposites. The synthesised materials were also confirmed via Raman spectroscopy. Using ferricyanide as the redox active probe, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) analyses indicated that 1:8 ratio of G/TiO2 exhibited the best current response and the lowest charge transfer resistance (Rct) of 1525 Ω. The potential of G/TiO2 for electrochemical sensing application was investigated using hydrogen peroxide (H2O2), a by-product of most enzymatic processes, as the analyte of interest. The sensitivity of the sensor towards H2O2 was 0.557 μA mM-1, with a limit of detection (LOD) at 56.89 μM. An in vitro cell proliferation assay was carried out to investigate the biocompatibility of the nanocomposites. The half-maximal inhibitory concentration (IC50) values obtained were >500 μg ml-1 for human lung fibroblasts (MRC5) and 5-25 μg ml-1 for human skin cells (HaCat). Royal Society of Chemistry 2018 Article PeerReviewed Siew, Qi Yan and Tham, Shiau Ying and Loh, Hwei San and Khiew, Poi Sim and Chiu, Wee Siong and Tan, Michelle T.T. (2018) One-step green hydrothermal synthesis of biocompatible graphene/TiO2 nanocomposites for non-enzymatic H2O2 detection and their cytotoxicity effects on human keratinocyte and lung fibroblast cells. Journal of Materials Chemistry B, 6 (8). pp. 1195-1206. ISSN 2050-750X https://doi.org/10.1039/c7tb02891a doi:10.1039/c7tb02891a
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Q Science (General)
QC Physics
spellingShingle Q Science (General)
QC Physics
Siew, Qi Yan
Tham, Shiau Ying
Loh, Hwei San
Khiew, Poi Sim
Chiu, Wee Siong
Tan, Michelle T.T.
One-step green hydrothermal synthesis of biocompatible graphene/TiO2 nanocomposites for non-enzymatic H2O2 detection and their cytotoxicity effects on human keratinocyte and lung fibroblast cells
description Highly sensitive and selective immunosensors that can detect disease biomarkers at ultra-low levels in early stages are urgently needed to reduce mortality risks. A facile and efficient approach using sonochemical-assisted solvent graphene exfoliation and a hydrothermal synthesis method has been used to prepare graphene/titanium dioxide (G/TiO2) nanocomposites. Nanocomposites containing different ratios of graphene and TiO2 precursors were prepared to determine the optimum composition of G/TiO2 that has the highest conductivity and electrocatalytic properties. Characterisation methods such as X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), transmission electron microscopy (TEM), and high resolution TEM (HRTEM) were used to study the crystallinity, surface characteristics, elemental composition, and morphology of the synthesised nanocomposites. The synthesised materials were also confirmed via Raman spectroscopy. Using ferricyanide as the redox active probe, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) analyses indicated that 1:8 ratio of G/TiO2 exhibited the best current response and the lowest charge transfer resistance (Rct) of 1525 Ω. The potential of G/TiO2 for electrochemical sensing application was investigated using hydrogen peroxide (H2O2), a by-product of most enzymatic processes, as the analyte of interest. The sensitivity of the sensor towards H2O2 was 0.557 μA mM-1, with a limit of detection (LOD) at 56.89 μM. An in vitro cell proliferation assay was carried out to investigate the biocompatibility of the nanocomposites. The half-maximal inhibitory concentration (IC50) values obtained were >500 μg ml-1 for human lung fibroblasts (MRC5) and 5-25 μg ml-1 for human skin cells (HaCat).
format Article
author Siew, Qi Yan
Tham, Shiau Ying
Loh, Hwei San
Khiew, Poi Sim
Chiu, Wee Siong
Tan, Michelle T.T.
author_facet Siew, Qi Yan
Tham, Shiau Ying
Loh, Hwei San
Khiew, Poi Sim
Chiu, Wee Siong
Tan, Michelle T.T.
author_sort Siew, Qi Yan
title One-step green hydrothermal synthesis of biocompatible graphene/TiO2 nanocomposites for non-enzymatic H2O2 detection and their cytotoxicity effects on human keratinocyte and lung fibroblast cells
title_short One-step green hydrothermal synthesis of biocompatible graphene/TiO2 nanocomposites for non-enzymatic H2O2 detection and their cytotoxicity effects on human keratinocyte and lung fibroblast cells
title_full One-step green hydrothermal synthesis of biocompatible graphene/TiO2 nanocomposites for non-enzymatic H2O2 detection and their cytotoxicity effects on human keratinocyte and lung fibroblast cells
title_fullStr One-step green hydrothermal synthesis of biocompatible graphene/TiO2 nanocomposites for non-enzymatic H2O2 detection and their cytotoxicity effects on human keratinocyte and lung fibroblast cells
title_full_unstemmed One-step green hydrothermal synthesis of biocompatible graphene/TiO2 nanocomposites for non-enzymatic H2O2 detection and their cytotoxicity effects on human keratinocyte and lung fibroblast cells
title_sort one-step green hydrothermal synthesis of biocompatible graphene/tio2 nanocomposites for non-enzymatic h2o2 detection and their cytotoxicity effects on human keratinocyte and lung fibroblast cells
publisher Royal Society of Chemistry
publishDate 2018
url http://eprints.um.edu.my/20663/
https://doi.org/10.1039/c7tb02891a
_version_ 1643691343709470720