Development of a new density correlation for carbon-based nanofluids using response surface methodology

Density is among the fundamental thermo-physical characteristics of fluids that are examined prior to carrying out performance analysis of the fluid. In this study, the effect of the design variables on the density of nanofluids was studied using response surface methodology (RSM). The quadratic mod...

Full description

Saved in:
Bibliographic Details
Main Authors: Montazer, Elham, Salami, Erfan, Yarmand, Hooman, Chowdhury, Zaira Zaman, Dahari, Mahidzal, Kazi, Salim Newaz, Badarudin, Ahmad
Format: Article
Published: Springer Verlag 2018
Subjects:
Online Access:http://eprints.um.edu.my/21221/
https://doi.org/10.1007/s10973-018-6978-4
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.21221
record_format eprints
spelling my.um.eprints.212212019-05-14T05:16:23Z http://eprints.um.edu.my/21221/ Development of a new density correlation for carbon-based nanofluids using response surface methodology Montazer, Elham Salami, Erfan Yarmand, Hooman Chowdhury, Zaira Zaman Dahari, Mahidzal Kazi, Salim Newaz Badarudin, Ahmad TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering Density is among the fundamental thermo-physical characteristics of fluids that are examined prior to carrying out performance analysis of the fluid. In this study, the effect of the design variables on the density of nanofluids was studied using response surface methodology (RSM). The quadratic model produced by RSM was employed to determine the performance factors, i.e., mass concentration and temperature with reasonably good accuracy. Improved experimental correlations were proposed for the density prediction of the carbon-based nanofluids based on the experimental data. Experimentally measured densities of two different nanofluids at the nanoparticle mass concentration of up to 0.1% and the temperature range of 20–40 °C were examined. The improvement in densities compared to the density of base fluid at 20 and 40 °C is approximately 0.15% for 0.1% fraction of MWCNT–COOH nanoparticles. Additionally, the densities of F-GNP nanofluids are increased by 0.056% compared to the density of distilled water. As a final point, the RSM results were compared with the results which got from the empirical data. It was detected that the optimal RSM model is accurate and the absolute maximum deviation measured values from the predicted densities of MWCNT–COOH and F-GNP nanofluids are 0.012 and 0.009%, respectively. Springer Verlag 2018 Article PeerReviewed Montazer, Elham and Salami, Erfan and Yarmand, Hooman and Chowdhury, Zaira Zaman and Dahari, Mahidzal and Kazi, Salim Newaz and Badarudin, Ahmad (2018) Development of a new density correlation for carbon-based nanofluids using response surface methodology. Journal of Thermal Analysis and Calorimetry, 132 (2). pp. 1399-1407. ISSN 1388-6150 https://doi.org/10.1007/s10973-018-6978-4 doi:10.1007/s10973-018-6978-4
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
Montazer, Elham
Salami, Erfan
Yarmand, Hooman
Chowdhury, Zaira Zaman
Dahari, Mahidzal
Kazi, Salim Newaz
Badarudin, Ahmad
Development of a new density correlation for carbon-based nanofluids using response surface methodology
description Density is among the fundamental thermo-physical characteristics of fluids that are examined prior to carrying out performance analysis of the fluid. In this study, the effect of the design variables on the density of nanofluids was studied using response surface methodology (RSM). The quadratic model produced by RSM was employed to determine the performance factors, i.e., mass concentration and temperature with reasonably good accuracy. Improved experimental correlations were proposed for the density prediction of the carbon-based nanofluids based on the experimental data. Experimentally measured densities of two different nanofluids at the nanoparticle mass concentration of up to 0.1% and the temperature range of 20–40 °C were examined. The improvement in densities compared to the density of base fluid at 20 and 40 °C is approximately 0.15% for 0.1% fraction of MWCNT–COOH nanoparticles. Additionally, the densities of F-GNP nanofluids are increased by 0.056% compared to the density of distilled water. As a final point, the RSM results were compared with the results which got from the empirical data. It was detected that the optimal RSM model is accurate and the absolute maximum deviation measured values from the predicted densities of MWCNT–COOH and F-GNP nanofluids are 0.012 and 0.009%, respectively.
format Article
author Montazer, Elham
Salami, Erfan
Yarmand, Hooman
Chowdhury, Zaira Zaman
Dahari, Mahidzal
Kazi, Salim Newaz
Badarudin, Ahmad
author_facet Montazer, Elham
Salami, Erfan
Yarmand, Hooman
Chowdhury, Zaira Zaman
Dahari, Mahidzal
Kazi, Salim Newaz
Badarudin, Ahmad
author_sort Montazer, Elham
title Development of a new density correlation for carbon-based nanofluids using response surface methodology
title_short Development of a new density correlation for carbon-based nanofluids using response surface methodology
title_full Development of a new density correlation for carbon-based nanofluids using response surface methodology
title_fullStr Development of a new density correlation for carbon-based nanofluids using response surface methodology
title_full_unstemmed Development of a new density correlation for carbon-based nanofluids using response surface methodology
title_sort development of a new density correlation for carbon-based nanofluids using response surface methodology
publisher Springer Verlag
publishDate 2018
url http://eprints.um.edu.my/21221/
https://doi.org/10.1007/s10973-018-6978-4
_version_ 1643691501542178816