Electrically evoked wrist extensor muscle fatigue throughout repetitive motion as measured by mechanomyography and near-infrared spectroscopy
Repetitive electrically-evoked muscle contraction leads to accelerated muscle fatigue. This study assessed electrically-evoked fatiguing muscle with changes to mechanomyography root mean square percentage (%RMS-MMG) and tissue saturation index (%TSI) in extensor carpi radialis. Forty healthy volunte...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
De Gruyter
2019
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/24012/ https://doi.org/10.1515/bmt-2018-0058 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaya |
id |
my.um.eprints.24012 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.240122020-03-12T01:16:06Z http://eprints.um.edu.my/24012/ Electrically evoked wrist extensor muscle fatigue throughout repetitive motion as measured by mechanomyography and near-infrared spectroscopy Mohamad Saadon, Nurul Salwani Hamzaid, Nur Azah Hasnan, Nazirah Dzulkifli, Muhammad Afiq Davis, Glen Macartney R Medicine Repetitive electrically-evoked muscle contraction leads to accelerated muscle fatigue. This study assessed electrically-evoked fatiguing muscle with changes to mechanomyography root mean square percentage (%RMS-MMG) and tissue saturation index (%TSI) in extensor carpi radialis. Forty healthy volunteers (n=40) performed repetitive electrical-evoked wrist extension to fatigue and results were analyzed pre- and post-fatigue, i.e. 50% power output (%PO) drop. Responses of %PO, %TSI and %RMS-MMG were correlated while the relationships between %RMS-MMG and %TSI were investigated using linear regression. The %TSI for both groups were negatively correlated with declining %PO as the ability of the muscle to take up oxygen became limited due to fatigued muscle. The %RMS-MMG behaved in two different patterns post-fatigue against declining %PO whereby; (i) group A showed positive correlation (%RMS-MMG decreased) throughout the session and (ii) group B demonstrated negative correlation (%RMS-MMG increased) with declining %PO until the end of the session. Regression analysis showed %TSI was inversely proportional to %RMS-MMG during post-fatigue in group A. Small gradients in both groups suggested that %TSI was not sensitive to the changes in %RMS-MMG and they were mutually exclusive. Most correlation and regression changed significantly post-fatigue indicating that after fatigue, the condition of muscle had changed mechanically and physiologically. © 2019 Walter de Gruyter GmbH, Berlin/Boston. De Gruyter 2019 Article PeerReviewed Mohamad Saadon, Nurul Salwani and Hamzaid, Nur Azah and Hasnan, Nazirah and Dzulkifli, Muhammad Afiq and Davis, Glen Macartney (2019) Electrically evoked wrist extensor muscle fatigue throughout repetitive motion as measured by mechanomyography and near-infrared spectroscopy. Biomedical Engineering / Biomedizinische Technik, 64 (4). pp. 439-448. ISSN 0013-5585 https://doi.org/10.1515/bmt-2018-0058 doi:10.1515/bmt-2018-0058 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
R Medicine |
spellingShingle |
R Medicine Mohamad Saadon, Nurul Salwani Hamzaid, Nur Azah Hasnan, Nazirah Dzulkifli, Muhammad Afiq Davis, Glen Macartney Electrically evoked wrist extensor muscle fatigue throughout repetitive motion as measured by mechanomyography and near-infrared spectroscopy |
description |
Repetitive electrically-evoked muscle contraction leads to accelerated muscle fatigue. This study assessed electrically-evoked fatiguing muscle with changes to mechanomyography root mean square percentage (%RMS-MMG) and tissue saturation index (%TSI) in extensor carpi radialis. Forty healthy volunteers (n=40) performed repetitive electrical-evoked wrist extension to fatigue and results were analyzed pre- and post-fatigue, i.e. 50% power output (%PO) drop. Responses of %PO, %TSI and %RMS-MMG were correlated while the relationships between %RMS-MMG and %TSI were investigated using linear regression. The %TSI for both groups were negatively correlated with declining %PO as the ability of the muscle to take up oxygen became limited due to fatigued muscle. The %RMS-MMG behaved in two different patterns post-fatigue against declining %PO whereby; (i) group A showed positive correlation (%RMS-MMG decreased) throughout the session and (ii) group B demonstrated negative correlation (%RMS-MMG increased) with declining %PO until the end of the session. Regression analysis showed %TSI was inversely proportional to %RMS-MMG during post-fatigue in group A. Small gradients in both groups suggested that %TSI was not sensitive to the changes in %RMS-MMG and they were mutually exclusive. Most correlation and regression changed significantly post-fatigue indicating that after fatigue, the condition of muscle had changed mechanically and physiologically. © 2019 Walter de Gruyter GmbH, Berlin/Boston. |
format |
Article |
author |
Mohamad Saadon, Nurul Salwani Hamzaid, Nur Azah Hasnan, Nazirah Dzulkifli, Muhammad Afiq Davis, Glen Macartney |
author_facet |
Mohamad Saadon, Nurul Salwani Hamzaid, Nur Azah Hasnan, Nazirah Dzulkifli, Muhammad Afiq Davis, Glen Macartney |
author_sort |
Mohamad Saadon, Nurul Salwani |
title |
Electrically evoked wrist extensor muscle fatigue throughout repetitive motion as measured by mechanomyography and near-infrared spectroscopy |
title_short |
Electrically evoked wrist extensor muscle fatigue throughout repetitive motion as measured by mechanomyography and near-infrared spectroscopy |
title_full |
Electrically evoked wrist extensor muscle fatigue throughout repetitive motion as measured by mechanomyography and near-infrared spectroscopy |
title_fullStr |
Electrically evoked wrist extensor muscle fatigue throughout repetitive motion as measured by mechanomyography and near-infrared spectroscopy |
title_full_unstemmed |
Electrically evoked wrist extensor muscle fatigue throughout repetitive motion as measured by mechanomyography and near-infrared spectroscopy |
title_sort |
electrically evoked wrist extensor muscle fatigue throughout repetitive motion as measured by mechanomyography and near-infrared spectroscopy |
publisher |
De Gruyter |
publishDate |
2019 |
url |
http://eprints.um.edu.my/24012/ https://doi.org/10.1515/bmt-2018-0058 |
_version_ |
1662755210832904192 |