Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array

In this letter, a highly sensitive refractive index biosensor applicable in medical devices is proposed. The biosensor design is analyzed for different concentrations of hemoglobin biomolecules. The 70nm shift in the wavelength is observed for two hemoglobin biomolecules with 1.34 and 1.36 refractiv...

Full description

Saved in:
Bibliographic Details
Main Authors: Patel, Shobhit K., Parmar, Juveriya, Trivedi, Himitri, Zakaria, Rozalina, Nguyen, Truong Khang, Dhasarathan, Vigneswaran
Format: Article
Published: Institute of Electrical and Electronics Engineers (IEEE) 2020
Subjects:
Online Access:http://eprints.um.edu.my/25409/
https://doi.org/10.1109/LPT.2020.2992085
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.25409
record_format eprints
spelling my.um.eprints.254092020-08-18T07:50:48Z http://eprints.um.edu.my/25409/ Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array Patel, Shobhit K. Parmar, Juveriya Trivedi, Himitri Zakaria, Rozalina Nguyen, Truong Khang Dhasarathan, Vigneswaran Q Science (General) QC Physics In this letter, a highly sensitive refractive index biosensor applicable in medical devices is proposed. The biosensor design is analyzed for different concentrations of hemoglobin biomolecules. The 70nm shift in the wavelength is observed for two hemoglobin biomolecules with 1.34 and 1.36 refractive index per unit (RIU). The highest sensitivity of 3500 nm/RIU is observed for these hemoglobin biomolecules. The results are analyzed for absorption, electric field and magnetic field. The design is also analyzed for different geometrical parameters like metasurface array thickness and silicon dioxide (SiO2) layer thickness. The increase in metasurface array thickness reduces the absorption of the design. The increase in the thickness of SiO2 layer increases the absorption till 0.6μm thickness than the response remains the same for other thicknesses. The proposed highly sensitive graphene-based metasurface array biosensor is applicable in medical and biosensing photovoltaic devices. © 1989-2012 IEEE. Institute of Electrical and Electronics Engineers (IEEE) 2020 Article PeerReviewed Patel, Shobhit K. and Parmar, Juveriya and Trivedi, Himitri and Zakaria, Rozalina and Nguyen, Truong Khang and Dhasarathan, Vigneswaran (2020) Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array. IEEE Photonics Technology Letters, 32 (12). pp. 681-684. ISSN 1041-1135 https://doi.org/10.1109/LPT.2020.2992085 doi:10.1109/LPT.2020.2992085
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Q Science (General)
QC Physics
spellingShingle Q Science (General)
QC Physics
Patel, Shobhit K.
Parmar, Juveriya
Trivedi, Himitri
Zakaria, Rozalina
Nguyen, Truong Khang
Dhasarathan, Vigneswaran
Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array
description In this letter, a highly sensitive refractive index biosensor applicable in medical devices is proposed. The biosensor design is analyzed for different concentrations of hemoglobin biomolecules. The 70nm shift in the wavelength is observed for two hemoglobin biomolecules with 1.34 and 1.36 refractive index per unit (RIU). The highest sensitivity of 3500 nm/RIU is observed for these hemoglobin biomolecules. The results are analyzed for absorption, electric field and magnetic field. The design is also analyzed for different geometrical parameters like metasurface array thickness and silicon dioxide (SiO2) layer thickness. The increase in metasurface array thickness reduces the absorption of the design. The increase in the thickness of SiO2 layer increases the absorption till 0.6μm thickness than the response remains the same for other thicknesses. The proposed highly sensitive graphene-based metasurface array biosensor is applicable in medical and biosensing photovoltaic devices. © 1989-2012 IEEE.
format Article
author Patel, Shobhit K.
Parmar, Juveriya
Trivedi, Himitri
Zakaria, Rozalina
Nguyen, Truong Khang
Dhasarathan, Vigneswaran
author_facet Patel, Shobhit K.
Parmar, Juveriya
Trivedi, Himitri
Zakaria, Rozalina
Nguyen, Truong Khang
Dhasarathan, Vigneswaran
author_sort Patel, Shobhit K.
title Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array
title_short Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array
title_full Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array
title_fullStr Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array
title_full_unstemmed Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array
title_sort highly sensitive graphene-based refractive index biosensor using gold metasurface array
publisher Institute of Electrical and Electronics Engineers (IEEE)
publishDate 2020
url http://eprints.um.edu.my/25409/
https://doi.org/10.1109/LPT.2020.2992085
_version_ 1680857029527207936