Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array
In this letter, a highly sensitive refractive index biosensor applicable in medical devices is proposed. The biosensor design is analyzed for different concentrations of hemoglobin biomolecules. The 70nm shift in the wavelength is observed for two hemoglobin biomolecules with 1.34 and 1.36 refractiv...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
Institute of Electrical and Electronics Engineers (IEEE)
2020
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/25409/ https://doi.org/10.1109/LPT.2020.2992085 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaya |
id |
my.um.eprints.25409 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.254092020-08-18T07:50:48Z http://eprints.um.edu.my/25409/ Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array Patel, Shobhit K. Parmar, Juveriya Trivedi, Himitri Zakaria, Rozalina Nguyen, Truong Khang Dhasarathan, Vigneswaran Q Science (General) QC Physics In this letter, a highly sensitive refractive index biosensor applicable in medical devices is proposed. The biosensor design is analyzed for different concentrations of hemoglobin biomolecules. The 70nm shift in the wavelength is observed for two hemoglobin biomolecules with 1.34 and 1.36 refractive index per unit (RIU). The highest sensitivity of 3500 nm/RIU is observed for these hemoglobin biomolecules. The results are analyzed for absorption, electric field and magnetic field. The design is also analyzed for different geometrical parameters like metasurface array thickness and silicon dioxide (SiO2) layer thickness. The increase in metasurface array thickness reduces the absorption of the design. The increase in the thickness of SiO2 layer increases the absorption till 0.6μm thickness than the response remains the same for other thicknesses. The proposed highly sensitive graphene-based metasurface array biosensor is applicable in medical and biosensing photovoltaic devices. © 1989-2012 IEEE. Institute of Electrical and Electronics Engineers (IEEE) 2020 Article PeerReviewed Patel, Shobhit K. and Parmar, Juveriya and Trivedi, Himitri and Zakaria, Rozalina and Nguyen, Truong Khang and Dhasarathan, Vigneswaran (2020) Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array. IEEE Photonics Technology Letters, 32 (12). pp. 681-684. ISSN 1041-1135 https://doi.org/10.1109/LPT.2020.2992085 doi:10.1109/LPT.2020.2992085 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
Q Science (General) QC Physics |
spellingShingle |
Q Science (General) QC Physics Patel, Shobhit K. Parmar, Juveriya Trivedi, Himitri Zakaria, Rozalina Nguyen, Truong Khang Dhasarathan, Vigneswaran Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array |
description |
In this letter, a highly sensitive refractive index biosensor applicable in medical devices is proposed. The biosensor design is analyzed for different concentrations of hemoglobin biomolecules. The 70nm shift in the wavelength is observed for two hemoglobin biomolecules with 1.34 and 1.36 refractive index per unit (RIU). The highest sensitivity of 3500 nm/RIU is observed for these hemoglobin biomolecules. The results are analyzed for absorption, electric field and magnetic field. The design is also analyzed for different geometrical parameters like metasurface array thickness and silicon dioxide (SiO2) layer thickness. The increase in metasurface array thickness reduces the absorption of the design. The increase in the thickness of SiO2 layer increases the absorption till 0.6μm thickness than the response remains the same for other thicknesses. The proposed highly sensitive graphene-based metasurface array biosensor is applicable in medical and biosensing photovoltaic devices. © 1989-2012 IEEE. |
format |
Article |
author |
Patel, Shobhit K. Parmar, Juveriya Trivedi, Himitri Zakaria, Rozalina Nguyen, Truong Khang Dhasarathan, Vigneswaran |
author_facet |
Patel, Shobhit K. Parmar, Juveriya Trivedi, Himitri Zakaria, Rozalina Nguyen, Truong Khang Dhasarathan, Vigneswaran |
author_sort |
Patel, Shobhit K. |
title |
Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array |
title_short |
Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array |
title_full |
Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array |
title_fullStr |
Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array |
title_full_unstemmed |
Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array |
title_sort |
highly sensitive graphene-based refractive index biosensor using gold metasurface array |
publisher |
Institute of Electrical and Electronics Engineers (IEEE) |
publishDate |
2020 |
url |
http://eprints.um.edu.my/25409/ https://doi.org/10.1109/LPT.2020.2992085 |
_version_ |
1680857029527207936 |