From one to three, modifications of sensing behavior with solvent system: DFT calculations and real-life application in detection of multianalytes (Cu2+, Ni2+ and Co2+) based on a colorimetric Schiff base probe
A rhodamine-based colorimetric sensor, RBOV has been synthesized and modified for selective detection of Cu2+, Ni2+ and Co2+ ions simultaneously in aqueous medium. The difference in color change upon binding with these three cations makes it an interesting multianalyte sensor. Furthermore, the detec...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
ELSEVIER
|
Online Access: | http://eprints.um.edu.my/28291/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaya |
id |
my.um.eprints.28291 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.282912022-04-12T07:43:50Z http://eprints.um.edu.my/28291/ From one to three, modifications of sensing behavior with solvent system: DFT calculations and real-life application in detection of multianalytes (Cu2+, Ni2+ and Co2+) based on a colorimetric Schiff base probe Pungut, Nur Amira Solehah Heng, Mok Piew Saad, Hazwani Mat Sim, Kae Shin Lee, Vannajan Sanghiran Tan, Kong Wai A rhodamine-based colorimetric sensor, RBOV has been synthesized and modified for selective detection of Cu2+, Ni2+ and Co2+ ions simultaneously in aqueous medium. The difference in color change upon binding with these three cations makes it an interesting multianalyte sensor. Furthermore, the detection limits of RBOV for Cu2+, Ni2+ and Co2+ are down to 4.0 x 10(-2) mu M, 3.2 x 10(-1) mu M and 4.8 x 10(-1) mu M respectively. The possible sensing mechanism analyzed from Benesi-Hildebrand plot, Job's plot, FTIR and DFT studies showed a 1:1 stoichiometry of sensor-metal complex for all three analytes. Practical application of sensor was conducted in real time using test strips and MTT assay was conducted to determine its cytotoxicity. (C) 2021 Elsevier B.V. All rights reserved. ELSEVIER Article NonPeerReviewed Pungut, Nur Amira Solehah and Heng, Mok Piew and Saad, Hazwani Mat and Sim, Kae Shin and Lee, Vannajan Sanghiran and Tan, Kong Wai From one to three, modifications of sensing behavior with solvent system: DFT calculations and real-life application in detection of multianalytes (Cu2+, Ni2+ and Co2+) based on a colorimetric Schiff base probe. JOURNAL OF MOLECULAR STRUCTURE, 1238. |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
description |
A rhodamine-based colorimetric sensor, RBOV has been synthesized and modified for selective detection of Cu2+, Ni2+ and Co2+ ions simultaneously in aqueous medium. The difference in color change upon binding with these three cations makes it an interesting multianalyte sensor. Furthermore, the detection limits of RBOV for Cu2+, Ni2+ and Co2+ are down to 4.0 x 10(-2) mu M, 3.2 x 10(-1) mu M and 4.8 x 10(-1) mu M respectively. The possible sensing mechanism analyzed from Benesi-Hildebrand plot, Job's plot, FTIR and DFT studies showed a 1:1 stoichiometry of sensor-metal complex for all three analytes. Practical application of sensor was conducted in real time using test strips and MTT assay was conducted to determine its cytotoxicity. (C) 2021 Elsevier B.V. All rights reserved. |
format |
Article |
author |
Pungut, Nur Amira Solehah Heng, Mok Piew Saad, Hazwani Mat Sim, Kae Shin Lee, Vannajan Sanghiran Tan, Kong Wai |
spellingShingle |
Pungut, Nur Amira Solehah Heng, Mok Piew Saad, Hazwani Mat Sim, Kae Shin Lee, Vannajan Sanghiran Tan, Kong Wai From one to three, modifications of sensing behavior with solvent system: DFT calculations and real-life application in detection of multianalytes (Cu2+, Ni2+ and Co2+) based on a colorimetric Schiff base probe |
author_facet |
Pungut, Nur Amira Solehah Heng, Mok Piew Saad, Hazwani Mat Sim, Kae Shin Lee, Vannajan Sanghiran Tan, Kong Wai |
author_sort |
Pungut, Nur Amira Solehah |
title |
From one to three, modifications of sensing behavior with solvent system: DFT calculations and real-life application in detection of multianalytes (Cu2+, Ni2+ and Co2+) based on a colorimetric Schiff base probe |
title_short |
From one to three, modifications of sensing behavior with solvent system: DFT calculations and real-life application in detection of multianalytes (Cu2+, Ni2+ and Co2+) based on a colorimetric Schiff base probe |
title_full |
From one to three, modifications of sensing behavior with solvent system: DFT calculations and real-life application in detection of multianalytes (Cu2+, Ni2+ and Co2+) based on a colorimetric Schiff base probe |
title_fullStr |
From one to three, modifications of sensing behavior with solvent system: DFT calculations and real-life application in detection of multianalytes (Cu2+, Ni2+ and Co2+) based on a colorimetric Schiff base probe |
title_full_unstemmed |
From one to three, modifications of sensing behavior with solvent system: DFT calculations and real-life application in detection of multianalytes (Cu2+, Ni2+ and Co2+) based on a colorimetric Schiff base probe |
title_sort |
from one to three, modifications of sensing behavior with solvent system: dft calculations and real-life application in detection of multianalytes (cu2+, ni2+ and co2+) based on a colorimetric schiff base probe |
publisher |
ELSEVIER |
url |
http://eprints.um.edu.my/28291/ |
_version_ |
1735409551344140288 |