Studies of thermoluminescence kinetic parameters of polymer pencil lead graphite under photon exposures

This study analysed thermoluminescence (TL) glow curves of the polymer pencil lead graphite (PPLG) due to its potential applications in radiation dosimetry. The TL glow curves provide information on the physical parameters of the defects participating in luminescence process. The glow curves for dif...

Full description

Saved in:
Bibliographic Details
Main Authors: Khandaker, Mayeen Uddin, Nawi, Siti Nurasiah Mat, Bradley, David Andrew, Lam, Siok Ee, Abdul Sani, Siti Fairus, Sulieman, Abdelmoneim
Format: Article
Published: Elsevier 2021
Subjects:
Online Access:http://eprints.um.edu.my/28491/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.28491
record_format eprints
spelling my.um.eprints.284912024-09-17T07:30:09Z http://eprints.um.edu.my/28491/ Studies of thermoluminescence kinetic parameters of polymer pencil lead graphite under photon exposures Khandaker, Mayeen Uddin Nawi, Siti Nurasiah Mat Bradley, David Andrew Lam, Siok Ee Abdul Sani, Siti Fairus Sulieman, Abdelmoneim QD Chemistry R Medicine (General) This study analysed thermoluminescence (TL) glow curves of the polymer pencil lead graphite (PPLG) due to its potential applications in radiation dosimetry. The TL glow curves provide information on the physical parameters of the defects participating in luminescence process. The glow curves for different diameters PPLG samples were obtained with varying temperature from 50 to 300 degrees C, at a fixed heating rate of 10 degrees Cs-1. A number of methods (initial rise, peak shape and curve fitting) were used to fit the TL glow peaks of the PPLG samples obtained under photon dose of 200 Gy. From the fitted TL signals, the trap parameters such as the order of kinetics, the activation energy, the frequency factor, etc. for the individual peaks were numerically determined. The lifetimes of TL process were calculated assuming the first-order kinetics. The results are compared among the different methods adopted in this study. Implications about the possible results in glow curve deconvolution are discussed. Elsevier 2021-08 Article PeerReviewed Khandaker, Mayeen Uddin and Nawi, Siti Nurasiah Mat and Bradley, David Andrew and Lam, Siok Ee and Abdul Sani, Siti Fairus and Sulieman, Abdelmoneim (2021) Studies of thermoluminescence kinetic parameters of polymer pencil lead graphite under photon exposures. Applied Radiation and Isotopes, 174. ISSN 0969-8043, DOI https://doi.org/10.1016/j.apradiso.2021.109757 <https://doi.org/10.1016/j.apradiso.2021.109757>. 10.1016/j.apradiso.2021.109757
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic QD Chemistry
R Medicine (General)
spellingShingle QD Chemistry
R Medicine (General)
Khandaker, Mayeen Uddin
Nawi, Siti Nurasiah Mat
Bradley, David Andrew
Lam, Siok Ee
Abdul Sani, Siti Fairus
Sulieman, Abdelmoneim
Studies of thermoluminescence kinetic parameters of polymer pencil lead graphite under photon exposures
description This study analysed thermoluminescence (TL) glow curves of the polymer pencil lead graphite (PPLG) due to its potential applications in radiation dosimetry. The TL glow curves provide information on the physical parameters of the defects participating in luminescence process. The glow curves for different diameters PPLG samples were obtained with varying temperature from 50 to 300 degrees C, at a fixed heating rate of 10 degrees Cs-1. A number of methods (initial rise, peak shape and curve fitting) were used to fit the TL glow peaks of the PPLG samples obtained under photon dose of 200 Gy. From the fitted TL signals, the trap parameters such as the order of kinetics, the activation energy, the frequency factor, etc. for the individual peaks were numerically determined. The lifetimes of TL process were calculated assuming the first-order kinetics. The results are compared among the different methods adopted in this study. Implications about the possible results in glow curve deconvolution are discussed.
format Article
author Khandaker, Mayeen Uddin
Nawi, Siti Nurasiah Mat
Bradley, David Andrew
Lam, Siok Ee
Abdul Sani, Siti Fairus
Sulieman, Abdelmoneim
author_facet Khandaker, Mayeen Uddin
Nawi, Siti Nurasiah Mat
Bradley, David Andrew
Lam, Siok Ee
Abdul Sani, Siti Fairus
Sulieman, Abdelmoneim
author_sort Khandaker, Mayeen Uddin
title Studies of thermoluminescence kinetic parameters of polymer pencil lead graphite under photon exposures
title_short Studies of thermoluminescence kinetic parameters of polymer pencil lead graphite under photon exposures
title_full Studies of thermoluminescence kinetic parameters of polymer pencil lead graphite under photon exposures
title_fullStr Studies of thermoluminescence kinetic parameters of polymer pencil lead graphite under photon exposures
title_full_unstemmed Studies of thermoluminescence kinetic parameters of polymer pencil lead graphite under photon exposures
title_sort studies of thermoluminescence kinetic parameters of polymer pencil lead graphite under photon exposures
publisher Elsevier
publishDate 2021
url http://eprints.um.edu.my/28491/
_version_ 1811682077436805120