Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites

Objective: To investigate the effect of light-curing distance on the effectiveness of cure (EC) of bulk-fill resin-based composites (RBCs). Materials and methods: Two bulk-fill RBCs (a Tetric N-Ceram Bulk Fill (TN) and a Filtek Bulk Fill (FK)) are evaluated. Specimens (4 mm high) are cured for 20 s...

Full description

Saved in:
Bibliographic Details
Main Authors: Diab, Rana Abdelbaset, Yap, Adrian Ujin, Gonzalez, Maria Angela Garcia, Yahya, N.A.
Format: Article
Published: Elsevier 2021
Subjects:
Online Access:http://eprints.um.edu.my/35630/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100108998&doi=10.1016%2fj.sdentj.2021.01.003&partnerID=40&md5=e0fb85dba734043a0d69dd28df579d56
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.35630
record_format eprints
spelling my.um.eprints.356302022-10-19T06:13:43Z http://eprints.um.edu.my/35630/ Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites Diab, Rana Abdelbaset Yap, Adrian Ujin Gonzalez, Maria Angela Garcia Yahya, N.A. R Medicine RK Dentistry Oral surger Objective: To investigate the effect of light-curing distance on the effectiveness of cure (EC) of bulk-fill resin-based composites (RBCs). Materials and methods: Two bulk-fill RBCs (a Tetric N-Ceram Bulk Fill (TN) and a Filtek Bulk Fill (FK)) are evaluated. Specimens (4 mm high) are cured for 20 s at different distances (0 mm (D0), 2 mm (D2), 4 mm (D4), 6 mm (D6) and 8 mm (D8)) and stored for 24 h in 100 relative humidity at 37 °C. The top and bottom surface hardness (SH) (n = 12) are assessed using a Knoop microhardness tester and the EC is calculated. The EC is characterized by the hardness ratio (HR) (mean bottom: top SH). An HR of 0.8 is used as the benchmark for an effective/adequate cure. Data are analyzed using one-way analysis of variance and Tukey's post hoc test (α = 0.05). Correlations between the top and bottom surfaces are examined using the Pearson correlation (α = 0.05). Results: For the TN, the HR at D8 is significantly lower than all other light-curing distances, while for the FK, it is significantly lower than D0 only. Conclusion: The effect of light-curing distance on the EC of bulk-fill RBCs is material dependent. Notwithstanding the light-curing distance, the EC of the FK and TN is below the threshold HR value of 0.8 when photopolymerized for 20 s in 4 mm increments in black opaque molds. © 2021 King Saud University Elsevier 2021-12 Article PeerReviewed Diab, Rana Abdelbaset and Yap, Adrian Ujin and Gonzalez, Maria Angela Garcia and Yahya, N.A. (2021) Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites. Saudi Dental Journal, 33 (8). pp. 1184-1189. ISSN 1013-9052, DOI https://doi.org/10.1016/j.sdentj.2021.01.003 <https://doi.org/10.1016/j.sdentj.2021.01.003>. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100108998&doi=10.1016%2fj.sdentj.2021.01.003&partnerID=40&md5=e0fb85dba734043a0d69dd28df579d56 10.1016/j.sdentj.2021.01.003
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic R Medicine
RK Dentistry
Oral surger
spellingShingle R Medicine
RK Dentistry
Oral surger
Diab, Rana Abdelbaset
Yap, Adrian Ujin
Gonzalez, Maria Angela Garcia
Yahya, N.A.
Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
description Objective: To investigate the effect of light-curing distance on the effectiveness of cure (EC) of bulk-fill resin-based composites (RBCs). Materials and methods: Two bulk-fill RBCs (a Tetric N-Ceram Bulk Fill (TN) and a Filtek Bulk Fill (FK)) are evaluated. Specimens (4 mm high) are cured for 20 s at different distances (0 mm (D0), 2 mm (D2), 4 mm (D4), 6 mm (D6) and 8 mm (D8)) and stored for 24 h in 100 relative humidity at 37 °C. The top and bottom surface hardness (SH) (n = 12) are assessed using a Knoop microhardness tester and the EC is calculated. The EC is characterized by the hardness ratio (HR) (mean bottom: top SH). An HR of 0.8 is used as the benchmark for an effective/adequate cure. Data are analyzed using one-way analysis of variance and Tukey's post hoc test (α = 0.05). Correlations between the top and bottom surfaces are examined using the Pearson correlation (α = 0.05). Results: For the TN, the HR at D8 is significantly lower than all other light-curing distances, while for the FK, it is significantly lower than D0 only. Conclusion: The effect of light-curing distance on the EC of bulk-fill RBCs is material dependent. Notwithstanding the light-curing distance, the EC of the FK and TN is below the threshold HR value of 0.8 when photopolymerized for 20 s in 4 mm increments in black opaque molds. © 2021 King Saud University
format Article
author Diab, Rana Abdelbaset
Yap, Adrian Ujin
Gonzalez, Maria Angela Garcia
Yahya, N.A.
author_facet Diab, Rana Abdelbaset
Yap, Adrian Ujin
Gonzalez, Maria Angela Garcia
Yahya, N.A.
author_sort Diab, Rana Abdelbaset
title Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
title_short Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
title_full Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
title_fullStr Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
title_full_unstemmed Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
title_sort impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
publisher Elsevier
publishDate 2021
url http://eprints.um.edu.my/35630/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100108998&doi=10.1016%2fj.sdentj.2021.01.003&partnerID=40&md5=e0fb85dba734043a0d69dd28df579d56
_version_ 1748181089339310080