Mitigating the dead-time effects on harmonics spectrum of inverter waveform by the confined band vsfpwm technique
The dead-time is necessary to be inserted between the gates drive pulses of the two power electronic switches in a one leg of any inverter to avoid a short circuit in the leg and the DC supply as well. However, adding the dead-time increases the low order harmonics of the output voltage/current wave...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
Institute of Advanced Engineering and Science
2021
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/35810/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaya |
id |
my.um.eprints.35810 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.358102023-11-15T01:38:17Z http://eprints.um.edu.my/35810/ Mitigating the dead-time effects on harmonics spectrum of inverter waveform by the confined band vsfpwm technique Attia, Hussain Che, Hang Seng Freddy, Tan Kheng Suan Elkhateb, Ahmad TA Engineering (General). Civil engineering (General) The dead-time is necessary to be inserted between the gates drive pulses of the two power electronic switches in a one leg of any inverter to avoid a short circuit in the leg and the DC supply as well. However, adding the dead-time increases the low order harmonics of the output voltage/current waveform of the inverter. This paper investigates the positive effects of decreasing the pulse width modulation (PWM) drive pulses number per fundamental period on the current low order harmonics. In addition, this paper evaluates the impact of the confined band variable switching frequency pulse width modulation (CB-VSFPWM) technique on inverter performance in terms of dead-time mitigating, and consequenctely lowering the low order harmonics. CB-VSFPWM technique reduces the total harmonic distortion (THD) levels in the inverter output current as well. Theoretical analysis of the CB-VSFPWM effectiveness in reducing the negative effect of the dead-time has explained in this study and confirmed by the MATLAB/Simulink simulation results. © 2021, Institute of Advanced Engineering and Science. All rights reserved. Institute of Advanced Engineering and Science 2021 Article PeerReviewed Attia, Hussain and Che, Hang Seng and Freddy, Tan Kheng Suan and Elkhateb, Ahmad (2021) Mitigating the dead-time effects on harmonics spectrum of inverter waveform by the confined band vsfpwm technique. International Journal of Power Electronics and Drive Systems, 12 (1). pp. 295-303. ISSN 2088-8694, DOI https://doi.org/10.11591/ijpeds.v12.i1.pp295-303 <https://doi.org/10.11591/ijpeds.v12.i1.pp295-303>. 10.11591/ijpeds.v12.i1.pp295-303 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Attia, Hussain Che, Hang Seng Freddy, Tan Kheng Suan Elkhateb, Ahmad Mitigating the dead-time effects on harmonics spectrum of inverter waveform by the confined band vsfpwm technique |
description |
The dead-time is necessary to be inserted between the gates drive pulses of the two power electronic switches in a one leg of any inverter to avoid a short circuit in the leg and the DC supply as well. However, adding the dead-time increases the low order harmonics of the output voltage/current waveform of the inverter. This paper investigates the positive effects of decreasing the pulse width modulation (PWM) drive pulses number per fundamental period on the current low order harmonics. In addition, this paper evaluates the impact of the confined band variable switching frequency pulse width modulation (CB-VSFPWM) technique on inverter performance in terms of dead-time mitigating, and consequenctely lowering the low order harmonics. CB-VSFPWM technique reduces the total harmonic distortion (THD) levels in the inverter output current as well. Theoretical analysis of the CB-VSFPWM effectiveness in reducing the negative effect of the dead-time has explained in this study and confirmed by the MATLAB/Simulink simulation results. © 2021, Institute of Advanced Engineering and Science. All rights reserved. |
format |
Article |
author |
Attia, Hussain Che, Hang Seng Freddy, Tan Kheng Suan Elkhateb, Ahmad |
author_facet |
Attia, Hussain Che, Hang Seng Freddy, Tan Kheng Suan Elkhateb, Ahmad |
author_sort |
Attia, Hussain |
title |
Mitigating the dead-time effects on harmonics spectrum of inverter waveform by the confined band vsfpwm technique |
title_short |
Mitigating the dead-time effects on harmonics spectrum of inverter waveform by the confined band vsfpwm technique |
title_full |
Mitigating the dead-time effects on harmonics spectrum of inverter waveform by the confined band vsfpwm technique |
title_fullStr |
Mitigating the dead-time effects on harmonics spectrum of inverter waveform by the confined band vsfpwm technique |
title_full_unstemmed |
Mitigating the dead-time effects on harmonics spectrum of inverter waveform by the confined band vsfpwm technique |
title_sort |
mitigating the dead-time effects on harmonics spectrum of inverter waveform by the confined band vsfpwm technique |
publisher |
Institute of Advanced Engineering and Science |
publishDate |
2021 |
url |
http://eprints.um.edu.my/35810/ |
_version_ |
1783876639924420608 |