Polarization and depolarization current analysis for field degraded cross linked polyethylene cables

Gradual deterioration in polymeric cable insulation system, whether due to continuous applications of high voltages or ageing mechanisms, may lead to eventual cable failure and subsequent electricity disruption. This has led to the growth in need for power utility companies to explore methods to clo...

Full description

Saved in:
Bibliographic Details
Main Authors: Sulaiman, S., Ariffin, A. Mohd, Kuan, T.M., Osman, M., Nik Ali, N.H., Illias, H.A.
Format: Conference or Workshop Item
Published: 2021
Subjects:
Online Access:http://eprints.um.edu.my/35850/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85111959602&doi=10.1109%2fICPADM49635.2021.9493953&partnerID=40&md5=666d2a0c65c2da39ea72562178ea0e7d
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.35850
record_format eprints
spelling my.um.eprints.358502024-10-18T08:14:58Z http://eprints.um.edu.my/35850/ Polarization and depolarization current analysis for field degraded cross linked polyethylene cables Sulaiman, S. Ariffin, A. Mohd Kuan, T.M. Osman, M. Nik Ali, N.H. Illias, H.A. TK Electrical engineering. Electronics Nuclear engineering Gradual deterioration in polymeric cable insulation system, whether due to continuous applications of high voltages or ageing mechanisms, may lead to eventual cable failure and subsequent electricity disruption. This has led to the growth in need for power utility companies to explore methods to closely monitor and assess the health of cable insulation, through condition-based monitoring (CBM) exercises. Polarization and depolarization current (PDC) analysis is a non-destructive insulation monitoring method that has been widely applied to assess the health of insulation for high voltage equipment especially power transformers. This study proposes to expand on the recent interest in PDC's assessment of cross-linked polyethylene (XLPE) cable insulation degradation. It attempts to investigate the PDC behaviour by performing experimental and simulation studies on in-service field degraded XLPE cables. Comparisons between PDC measurements and simulations for 39 field cables saw matching patterns in terms of categorization by conductivity values. Based on works done by established researchers, a five level PDC based CBM categorization for cable maintenance was proposed, ranging from healthy to moderately degraded to severely degraded cable insulation conditions. Comparison between the proposed and existing PDC based CBM table of a power utility company saw a 76.92 match, suggesting that the technique can be used to ascertain cable insulation degradation. © 2021 IEEE. 2021 Conference or Workshop Item PeerReviewed Sulaiman, S. and Ariffin, A. Mohd and Kuan, T.M. and Osman, M. and Nik Ali, N.H. and Illias, H.A. (2021) Polarization and depolarization current analysis for field degraded cross linked polyethylene cables. In: 13th IEEE International Conference on the Properties and Applications of Dielectric Materials, ICPADM 2021, 12-14 July 2021, Virtual, Online. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85111959602&doi=10.1109%2fICPADM49635.2021.9493953&partnerID=40&md5=666d2a0c65c2da39ea72562178ea0e7d
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Sulaiman, S.
Ariffin, A. Mohd
Kuan, T.M.
Osman, M.
Nik Ali, N.H.
Illias, H.A.
Polarization and depolarization current analysis for field degraded cross linked polyethylene cables
description Gradual deterioration in polymeric cable insulation system, whether due to continuous applications of high voltages or ageing mechanisms, may lead to eventual cable failure and subsequent electricity disruption. This has led to the growth in need for power utility companies to explore methods to closely monitor and assess the health of cable insulation, through condition-based monitoring (CBM) exercises. Polarization and depolarization current (PDC) analysis is a non-destructive insulation monitoring method that has been widely applied to assess the health of insulation for high voltage equipment especially power transformers. This study proposes to expand on the recent interest in PDC's assessment of cross-linked polyethylene (XLPE) cable insulation degradation. It attempts to investigate the PDC behaviour by performing experimental and simulation studies on in-service field degraded XLPE cables. Comparisons between PDC measurements and simulations for 39 field cables saw matching patterns in terms of categorization by conductivity values. Based on works done by established researchers, a five level PDC based CBM categorization for cable maintenance was proposed, ranging from healthy to moderately degraded to severely degraded cable insulation conditions. Comparison between the proposed and existing PDC based CBM table of a power utility company saw a 76.92 match, suggesting that the technique can be used to ascertain cable insulation degradation. © 2021 IEEE.
format Conference or Workshop Item
author Sulaiman, S.
Ariffin, A. Mohd
Kuan, T.M.
Osman, M.
Nik Ali, N.H.
Illias, H.A.
author_facet Sulaiman, S.
Ariffin, A. Mohd
Kuan, T.M.
Osman, M.
Nik Ali, N.H.
Illias, H.A.
author_sort Sulaiman, S.
title Polarization and depolarization current analysis for field degraded cross linked polyethylene cables
title_short Polarization and depolarization current analysis for field degraded cross linked polyethylene cables
title_full Polarization and depolarization current analysis for field degraded cross linked polyethylene cables
title_fullStr Polarization and depolarization current analysis for field degraded cross linked polyethylene cables
title_full_unstemmed Polarization and depolarization current analysis for field degraded cross linked polyethylene cables
title_sort polarization and depolarization current analysis for field degraded cross linked polyethylene cables
publishDate 2021
url http://eprints.um.edu.my/35850/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85111959602&doi=10.1109%2fICPADM49635.2021.9493953&partnerID=40&md5=666d2a0c65c2da39ea72562178ea0e7d
_version_ 1814047522392375296