Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm
Conventional way of transmitting the generated power from remote power stations through overhead transmission lines to the load centers causes inefficiencies and power loss. This problem can be minimized by integrating more RE in the existing transmission network. Net metering (NM) can increase the...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
2021
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/36141/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85124802411&doi=10.1109%2fICCCA52192.2021.9666242&partnerID=40&md5=ed0e484f0b6917374e6fd40756999417 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaya |
id |
my.um.eprints.36141 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.361412024-10-28T03:57:54Z http://eprints.um.edu.my/36141/ Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm Hannan, S.-B. Hassan Siddiquee, S. Ahmed, T. Ahmad, S. Hossain, Z. Mekhilef, S. TK Electrical engineering. Electronics Nuclear engineering Conventional way of transmitting the generated power from remote power stations through overhead transmission lines to the load centers causes inefficiencies and power loss. This problem can be minimized by integrating more RE in the existing transmission network. Net metering (NM) can increase the photovoltaic (PV) penetration near the load centers in the grid. NM can solve the deficit of power demand by supplying surplus power to the grid and can ensure maximum usage of generated solar energy. However, optimal placement of PV system for NM is very much important for maintaining voltage stability of the distribution grid. This paper aims to find the optimal placement of PV system for NM using Artificial Bee Colony (ABC) algorithm where voltage deviation and power losses are considered as objective functions. IEEE 14 and 39-bus Bangladesh power system networks are considered as test benches for the optimal placement of the PV system. The simulations are conducted in MATLAB and results demonstrate that by placing the PV optimally in the 14 and 39-bus Bangladesh power grid model, the real and reactive power loss can be reduced by 46 and 49 respectively. © 2021 IEEE. 2021 Conference or Workshop Item PeerReviewed Hannan, S.-B. and Hassan Siddiquee, S. and Ahmed, T. and Ahmad, S. and Hossain, Z. and Mekhilef, S. (2021) Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm. In: 6th IEEE International Conference on Computing, Communication and Automation, ICCCA 2021, 17-19 December 2021, Arad. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85124802411&doi=10.1109%2fICCCA52192.2021.9666242&partnerID=40&md5=ed0e484f0b6917374e6fd40756999417 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Hannan, S.-B. Hassan Siddiquee, S. Ahmed, T. Ahmad, S. Hossain, Z. Mekhilef, S. Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm |
description |
Conventional way of transmitting the generated power from remote power stations through overhead transmission lines to the load centers causes inefficiencies and power loss. This problem can be minimized by integrating more RE in the existing transmission network. Net metering (NM) can increase the photovoltaic (PV) penetration near the load centers in the grid. NM can solve the deficit of power demand by supplying surplus power to the grid and can ensure maximum usage of generated solar energy. However, optimal placement of PV system for NM is very much important for maintaining voltage stability of the distribution grid. This paper aims to find the optimal placement of PV system for NM using Artificial Bee Colony (ABC) algorithm where voltage deviation and power losses are considered as objective functions. IEEE 14 and 39-bus Bangladesh power system networks are considered as test benches for the optimal placement of the PV system. The simulations are conducted in MATLAB and results demonstrate that by placing the PV optimally in the 14 and 39-bus Bangladesh power grid model, the real and reactive power loss can be reduced by 46 and 49 respectively. © 2021 IEEE. |
format |
Conference or Workshop Item |
author |
Hannan, S.-B. Hassan Siddiquee, S. Ahmed, T. Ahmad, S. Hossain, Z. Mekhilef, S. |
author_facet |
Hannan, S.-B. Hassan Siddiquee, S. Ahmed, T. Ahmad, S. Hossain, Z. Mekhilef, S. |
author_sort |
Hannan, S.-B. |
title |
Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm |
title_short |
Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm |
title_full |
Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm |
title_fullStr |
Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm |
title_full_unstemmed |
Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm |
title_sort |
optimal placement of solar pv in bangladesh power system network for net metering using artificial bee colony algorithm |
publishDate |
2021 |
url |
http://eprints.um.edu.my/36141/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85124802411&doi=10.1109%2fICCCA52192.2021.9666242&partnerID=40&md5=ed0e484f0b6917374e6fd40756999417 |
_version_ |
1814933194721460224 |