Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm

Conventional way of transmitting the generated power from remote power stations through overhead transmission lines to the load centers causes inefficiencies and power loss. This problem can be minimized by integrating more RE in the existing transmission network. Net metering (NM) can increase the...

Full description

Saved in:
Bibliographic Details
Main Authors: Hannan, S.-B., Hassan Siddiquee, S., Ahmed, T., Ahmad, S., Hossain, Z., Mekhilef, S.
Format: Conference or Workshop Item
Published: 2021
Subjects:
Online Access:http://eprints.um.edu.my/36141/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85124802411&doi=10.1109%2fICCCA52192.2021.9666242&partnerID=40&md5=ed0e484f0b6917374e6fd40756999417
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.36141
record_format eprints
spelling my.um.eprints.361412024-10-28T03:57:54Z http://eprints.um.edu.my/36141/ Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm Hannan, S.-B. Hassan Siddiquee, S. Ahmed, T. Ahmad, S. Hossain, Z. Mekhilef, S. TK Electrical engineering. Electronics Nuclear engineering Conventional way of transmitting the generated power from remote power stations through overhead transmission lines to the load centers causes inefficiencies and power loss. This problem can be minimized by integrating more RE in the existing transmission network. Net metering (NM) can increase the photovoltaic (PV) penetration near the load centers in the grid. NM can solve the deficit of power demand by supplying surplus power to the grid and can ensure maximum usage of generated solar energy. However, optimal placement of PV system for NM is very much important for maintaining voltage stability of the distribution grid. This paper aims to find the optimal placement of PV system for NM using Artificial Bee Colony (ABC) algorithm where voltage deviation and power losses are considered as objective functions. IEEE 14 and 39-bus Bangladesh power system networks are considered as test benches for the optimal placement of the PV system. The simulations are conducted in MATLAB and results demonstrate that by placing the PV optimally in the 14 and 39-bus Bangladesh power grid model, the real and reactive power loss can be reduced by 46 and 49 respectively. © 2021 IEEE. 2021 Conference or Workshop Item PeerReviewed Hannan, S.-B. and Hassan Siddiquee, S. and Ahmed, T. and Ahmad, S. and Hossain, Z. and Mekhilef, S. (2021) Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm. In: 6th IEEE International Conference on Computing, Communication and Automation, ICCCA 2021, 17-19 December 2021, Arad. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85124802411&doi=10.1109%2fICCCA52192.2021.9666242&partnerID=40&md5=ed0e484f0b6917374e6fd40756999417
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Hannan, S.-B.
Hassan Siddiquee, S.
Ahmed, T.
Ahmad, S.
Hossain, Z.
Mekhilef, S.
Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm
description Conventional way of transmitting the generated power from remote power stations through overhead transmission lines to the load centers causes inefficiencies and power loss. This problem can be minimized by integrating more RE in the existing transmission network. Net metering (NM) can increase the photovoltaic (PV) penetration near the load centers in the grid. NM can solve the deficit of power demand by supplying surplus power to the grid and can ensure maximum usage of generated solar energy. However, optimal placement of PV system for NM is very much important for maintaining voltage stability of the distribution grid. This paper aims to find the optimal placement of PV system for NM using Artificial Bee Colony (ABC) algorithm where voltage deviation and power losses are considered as objective functions. IEEE 14 and 39-bus Bangladesh power system networks are considered as test benches for the optimal placement of the PV system. The simulations are conducted in MATLAB and results demonstrate that by placing the PV optimally in the 14 and 39-bus Bangladesh power grid model, the real and reactive power loss can be reduced by 46 and 49 respectively. © 2021 IEEE.
format Conference or Workshop Item
author Hannan, S.-B.
Hassan Siddiquee, S.
Ahmed, T.
Ahmad, S.
Hossain, Z.
Mekhilef, S.
author_facet Hannan, S.-B.
Hassan Siddiquee, S.
Ahmed, T.
Ahmad, S.
Hossain, Z.
Mekhilef, S.
author_sort Hannan, S.-B.
title Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm
title_short Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm
title_full Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm
title_fullStr Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm
title_full_unstemmed Optimal placement of solar PV in Bangladesh power system network for net metering using artificial bee colony algorithm
title_sort optimal placement of solar pv in bangladesh power system network for net metering using artificial bee colony algorithm
publishDate 2021
url http://eprints.um.edu.my/36141/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85124802411&doi=10.1109%2fICCCA52192.2021.9666242&partnerID=40&md5=ed0e484f0b6917374e6fd40756999417
_version_ 1814933194721460224