Model predictive direct torque with fault tolerance control for a permanent magnet synchronous generator based on Vienna rectifier

This paper presents the fault tolerance of model predictive direct torque control for a permanent magnet synchronous generator under a faulty Vienna rectifier. The fault applied includes open-switch and short-switch fault in a particular active switching device of the Vienna rectifier. The measured...

Full description

Saved in:
Bibliographic Details
Main Authors: Yip, Sook Yee, Yong, Dek Wei, Yiauw, Kah Haur, Tan, Xiao Jian, Wong, Jorinda Yuh Ruh
Format: Article
Published: Institute of Electrical and Electronics Engineers 2022
Subjects:
Online Access:http://eprints.um.edu.my/41500/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.41500
record_format eprints
spelling my.um.eprints.415002023-11-06T05:56:26Z http://eprints.um.edu.my/41500/ Model predictive direct torque with fault tolerance control for a permanent magnet synchronous generator based on Vienna rectifier Yip, Sook Yee Yong, Dek Wei Yiauw, Kah Haur Tan, Xiao Jian Wong, Jorinda Yuh Ruh QA75 Electronic computers. Computer science TK Electrical engineering. Electronics Nuclear engineering This paper presents the fault tolerance of model predictive direct torque control for a permanent magnet synchronous generator under a faulty Vienna rectifier. The fault applied includes open-switch and short-switch fault in a particular active switching device of the Vienna rectifier. The measured input current is used in the proposed fault diagnosis approach to detect the switch fault's position without any additional hardware being implemented. Whenever a switching fault occurs at any phase of the Vienna rectifier, the available switching vectors for prediction control are reduced from five to four. The feasibility and effectiveness of the proposed fault tolerance model predictive direct torque control under a faulty Vienna rectifier are demonstrated and investigated through MATLAB/Simulink. The results show that it is feasible for the proposed method to be operated under a short-switch fault with slightly higher total harmonics distortion of the input current but out of control under an open-switch fault. Institute of Electrical and Electronics Engineers 2022 Article PeerReviewed Yip, Sook Yee and Yong, Dek Wei and Yiauw, Kah Haur and Tan, Xiao Jian and Wong, Jorinda Yuh Ruh (2022) Model predictive direct torque with fault tolerance control for a permanent magnet synchronous generator based on Vienna rectifier. IEEE Access, 10. pp. 94998-95007. ISSN 2169-3536, DOI https://doi.org/10.1109/ACCESS.2022.3204809 <https://doi.org/10.1109/ACCESS.2022.3204809>. 10.1109/ACCESS.2022.3204809
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic QA75 Electronic computers. Computer science
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle QA75 Electronic computers. Computer science
TK Electrical engineering. Electronics Nuclear engineering
Yip, Sook Yee
Yong, Dek Wei
Yiauw, Kah Haur
Tan, Xiao Jian
Wong, Jorinda Yuh Ruh
Model predictive direct torque with fault tolerance control for a permanent magnet synchronous generator based on Vienna rectifier
description This paper presents the fault tolerance of model predictive direct torque control for a permanent magnet synchronous generator under a faulty Vienna rectifier. The fault applied includes open-switch and short-switch fault in a particular active switching device of the Vienna rectifier. The measured input current is used in the proposed fault diagnosis approach to detect the switch fault's position without any additional hardware being implemented. Whenever a switching fault occurs at any phase of the Vienna rectifier, the available switching vectors for prediction control are reduced from five to four. The feasibility and effectiveness of the proposed fault tolerance model predictive direct torque control under a faulty Vienna rectifier are demonstrated and investigated through MATLAB/Simulink. The results show that it is feasible for the proposed method to be operated under a short-switch fault with slightly higher total harmonics distortion of the input current but out of control under an open-switch fault.
format Article
author Yip, Sook Yee
Yong, Dek Wei
Yiauw, Kah Haur
Tan, Xiao Jian
Wong, Jorinda Yuh Ruh
author_facet Yip, Sook Yee
Yong, Dek Wei
Yiauw, Kah Haur
Tan, Xiao Jian
Wong, Jorinda Yuh Ruh
author_sort Yip, Sook Yee
title Model predictive direct torque with fault tolerance control for a permanent magnet synchronous generator based on Vienna rectifier
title_short Model predictive direct torque with fault tolerance control for a permanent magnet synchronous generator based on Vienna rectifier
title_full Model predictive direct torque with fault tolerance control for a permanent magnet synchronous generator based on Vienna rectifier
title_fullStr Model predictive direct torque with fault tolerance control for a permanent magnet synchronous generator based on Vienna rectifier
title_full_unstemmed Model predictive direct torque with fault tolerance control for a permanent magnet synchronous generator based on Vienna rectifier
title_sort model predictive direct torque with fault tolerance control for a permanent magnet synchronous generator based on vienna rectifier
publisher Institute of Electrical and Electronics Engineers
publishDate 2022
url http://eprints.um.edu.my/41500/
_version_ 1783876718915747840