Comparison of smartphone-based and automated refraction with subjective refraction for screening of refractive errors
Purpose To compare Netra smartphone-based and automated refraction with subjective refraction for screening of refractive errors. Methods Cross-sectional study at the University of Malaya Medical Centre, Kuala Lumpur. Subjects underwent subjective refraction, then automated refraction, and finally N...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Published: |
Taylor & Francis Inc
2022
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/41508/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaya |
id |
my.um.eprints.41508 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.415082023-11-06T03:52:23Z http://eprints.um.edu.my/41508/ Comparison of smartphone-based and automated refraction with subjective refraction for screening of refractive errors Ee, Chye Li Samsudin, Amir Optometry. Opticians. Eyeglasses Purpose To compare Netra smartphone-based and automated refraction with subjective refraction for screening of refractive errors. Methods Cross-sectional study at the University of Malaya Medical Centre, Kuala Lumpur. Subjects underwent subjective refraction, then automated refraction, and finally Netra smartphone-based refraction. All results were converted to power vectors (M, J0 and J45) and were analysed using repeated-measures ANOVA and Bland-Altman plots. Sensitivity and specificity were determined. The best cut-off points were determined from ROC curve analysis. P Results Data from the right eyes of 204 subjects were analysed. Mean age was 36.6 +/- 15.7 years (range 16-78 years). Spherical equivalent mean (95% CI)] from Netra and automated refraction were similar, and both more myopic than subjective refraction; -2.87 (-3.23 to -2.51), -2.85 (-3.21 to -2.49) and -2.46 (-2.83 to -2.10) respectively (p < .001). Differences in J0 and J45 between Netra and subjective refraction were not statistically significant (0.10 vs 0.11 and 0.01 vs -0.02 respectively, both p > .05), but those between automated and subjective refraction were (0.06 vs 0.11 and 0.07 vs -0.02, p = .004 and p < .001 respectively). Bland Altman plots showed the 95% limits of agreement with Netra refraction were wider than with automated refraction (-2.21D to 1.42D vs. -1.90D to 1.16D respectively). Conclusion Netra smartphone-based refraction gives similar readings to automated refraction, and both show myopic overestimation when compared to subjective refraction. However, due to non-insignificant practical usage issues, its use as a screening tool for refractive errors is limited. Taylor & Francis Inc 2022-09-03 Article PeerReviewed Ee, Chye Li and Samsudin, Amir (2022) Comparison of smartphone-based and automated refraction with subjective refraction for screening of refractive errors. Ophthalmic Epidemiology, 29 (5). pp. 588-594. ISSN 0928-6586, DOI https://doi.org/10.1080/09286586.2021.1986550 <https://doi.org/10.1080/09286586.2021.1986550>. 10.1080/09286586.2021.1986550 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
Optometry. Opticians. Eyeglasses |
spellingShingle |
Optometry. Opticians. Eyeglasses Ee, Chye Li Samsudin, Amir Comparison of smartphone-based and automated refraction with subjective refraction for screening of refractive errors |
description |
Purpose To compare Netra smartphone-based and automated refraction with subjective refraction for screening of refractive errors. Methods Cross-sectional study at the University of Malaya Medical Centre, Kuala Lumpur. Subjects underwent subjective refraction, then automated refraction, and finally Netra smartphone-based refraction. All results were converted to power vectors (M, J0 and J45) and were analysed using repeated-measures ANOVA and Bland-Altman plots. Sensitivity and specificity were determined. The best cut-off points were determined from ROC curve analysis. P Results Data from the right eyes of 204 subjects were analysed. Mean age was 36.6 +/- 15.7 years (range 16-78 years). Spherical equivalent mean (95% CI)] from Netra and automated refraction were similar, and both more myopic than subjective refraction; -2.87 (-3.23 to -2.51), -2.85 (-3.21 to -2.49) and -2.46 (-2.83 to -2.10) respectively (p < .001). Differences in J0 and J45 between Netra and subjective refraction were not statistically significant (0.10 vs 0.11 and 0.01 vs -0.02 respectively, both p > .05), but those between automated and subjective refraction were (0.06 vs 0.11 and 0.07 vs -0.02, p = .004 and p < .001 respectively). Bland Altman plots showed the 95% limits of agreement with Netra refraction were wider than with automated refraction (-2.21D to 1.42D vs. -1.90D to 1.16D respectively). Conclusion Netra smartphone-based refraction gives similar readings to automated refraction, and both show myopic overestimation when compared to subjective refraction. However, due to non-insignificant practical usage issues, its use as a screening tool for refractive errors is limited. |
format |
Article |
author |
Ee, Chye Li Samsudin, Amir |
author_facet |
Ee, Chye Li Samsudin, Amir |
author_sort |
Ee, Chye Li |
title |
Comparison of smartphone-based and automated refraction with subjective refraction for screening of refractive errors |
title_short |
Comparison of smartphone-based and automated refraction with subjective refraction for screening of refractive errors |
title_full |
Comparison of smartphone-based and automated refraction with subjective refraction for screening of refractive errors |
title_fullStr |
Comparison of smartphone-based and automated refraction with subjective refraction for screening of refractive errors |
title_full_unstemmed |
Comparison of smartphone-based and automated refraction with subjective refraction for screening of refractive errors |
title_sort |
comparison of smartphone-based and automated refraction with subjective refraction for screening of refractive errors |
publisher |
Taylor & Francis Inc |
publishDate |
2022 |
url |
http://eprints.um.edu.my/41508/ |
_version_ |
1783876719831154688 |