Evaluation of the marginal fit of a CAD/CAM zirconia-based ceramic crown system

Purpose: To evaluate the marginal fit of zirconia (Zi) CAD/CAM crowns in terms of gap and overhang compared to lithium disilicate (LDS) CAD/CAM crowns, as well as the effect of finish line design on marginal accuracy. Materials and Methods: Stone dies were acquired from two master metal dies with tw...

Full description

Saved in:
Bibliographic Details
Main Authors: Baig, Mirza Rustum, Al-Tarakemah, Yacoub, Abu Kasim, Noor Hayaty, Omar, Ridwaan
Format: Article
Published: 2022
Subjects:
Online Access:http://eprints.um.edu.my/41997/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.41997
record_format eprints
spelling my.um.eprints.419972023-10-18T07:04:18Z http://eprints.um.edu.my/41997/ Evaluation of the marginal fit of a CAD/CAM zirconia-based ceramic crown system Baig, Mirza Rustum Al-Tarakemah, Yacoub Abu Kasim, Noor Hayaty Omar, Ridwaan Oral surger Purpose: To evaluate the marginal fit of zirconia (Zi) CAD/CAM crowns in terms of gap and overhang compared to lithium disilicate (LDS) CAD/CAM crowns, as well as the effect of finish line design on marginal accuracy. Materials and Methods: Stone dies were acquired from two master metal dies with two different finish lines (n = 20 each) and scanned to produce digital models. Ceramic crowns (ZS-Ronde Zi] and IPS e.max CAD LDS]) were designed and milled on the resulting 40 dies: 10 Zi-shoulder, 10 Zi-chamfer, 10 LDS-shoulder, and 10 LDS-chamfer. Marginal gap and overhang were evaluated at six designated margin locations. The data were obtained, and the influence of material and finish line on the marginal fit of crowns was assessed using two-way analysis of variance and Bonferroni multiple comparisons test (alpha = .05). Results: The mean marginal gap and overhang on Zi crowns were 30 +/- 14 mu m and 79 +/- 27 mu m, respectively, for the shoulder, and were 68 +/- 34 mu m and 104 +/- 34 mu m, respectively, for the chamfer. The corresponding values for LDS crowns were 57 +/- 22 mu m and 74 +/- 29 mu m for the shoulder and 62 +/- 12 mu m and 59 +/- 27 mu m for the chamfer. ANOVA revealed that the differences in marginal gap between the two materials were not significant (P > .05), but that the finish line effect and interaction were significant (P < .05). With regard to marginal overhang, significant differences were found between Zi and LDS crowns (P < .05), although the finish line geometries did not show any significant differences (P> .05). LDS crowns showed no differences between shoulder and chamfer margins for gap or overhang (P > .05), whereas significant differences were found in marginal gap between the Zi shoulder and chamfer margins (P < .005). Conclusion: In terms of marginal accuracy, shoulder margins produced smaller marginal gaps compared to chamfers in Zi CAD/CAM crowns. 2022-05 Article PeerReviewed Baig, Mirza Rustum and Al-Tarakemah, Yacoub and Abu Kasim, Noor Hayaty and Omar, Ridwaan (2022) Evaluation of the marginal fit of a CAD/CAM zirconia-based ceramic crown system. International Journal of Prosthodontics, 35 (3). pp. 319-329. ISSN 0893-2174, DOI https://doi.org/10.11607/ijp.6654 <https://doi.org/10.11607/ijp.6654>. 10.11607/ijp.6654
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Oral surger
spellingShingle Oral surger
Baig, Mirza Rustum
Al-Tarakemah, Yacoub
Abu Kasim, Noor Hayaty
Omar, Ridwaan
Evaluation of the marginal fit of a CAD/CAM zirconia-based ceramic crown system
description Purpose: To evaluate the marginal fit of zirconia (Zi) CAD/CAM crowns in terms of gap and overhang compared to lithium disilicate (LDS) CAD/CAM crowns, as well as the effect of finish line design on marginal accuracy. Materials and Methods: Stone dies were acquired from two master metal dies with two different finish lines (n = 20 each) and scanned to produce digital models. Ceramic crowns (ZS-Ronde Zi] and IPS e.max CAD LDS]) were designed and milled on the resulting 40 dies: 10 Zi-shoulder, 10 Zi-chamfer, 10 LDS-shoulder, and 10 LDS-chamfer. Marginal gap and overhang were evaluated at six designated margin locations. The data were obtained, and the influence of material and finish line on the marginal fit of crowns was assessed using two-way analysis of variance and Bonferroni multiple comparisons test (alpha = .05). Results: The mean marginal gap and overhang on Zi crowns were 30 +/- 14 mu m and 79 +/- 27 mu m, respectively, for the shoulder, and were 68 +/- 34 mu m and 104 +/- 34 mu m, respectively, for the chamfer. The corresponding values for LDS crowns were 57 +/- 22 mu m and 74 +/- 29 mu m for the shoulder and 62 +/- 12 mu m and 59 +/- 27 mu m for the chamfer. ANOVA revealed that the differences in marginal gap between the two materials were not significant (P > .05), but that the finish line effect and interaction were significant (P < .05). With regard to marginal overhang, significant differences were found between Zi and LDS crowns (P < .05), although the finish line geometries did not show any significant differences (P> .05). LDS crowns showed no differences between shoulder and chamfer margins for gap or overhang (P > .05), whereas significant differences were found in marginal gap between the Zi shoulder and chamfer margins (P < .005). Conclusion: In terms of marginal accuracy, shoulder margins produced smaller marginal gaps compared to chamfers in Zi CAD/CAM crowns.
format Article
author Baig, Mirza Rustum
Al-Tarakemah, Yacoub
Abu Kasim, Noor Hayaty
Omar, Ridwaan
author_facet Baig, Mirza Rustum
Al-Tarakemah, Yacoub
Abu Kasim, Noor Hayaty
Omar, Ridwaan
author_sort Baig, Mirza Rustum
title Evaluation of the marginal fit of a CAD/CAM zirconia-based ceramic crown system
title_short Evaluation of the marginal fit of a CAD/CAM zirconia-based ceramic crown system
title_full Evaluation of the marginal fit of a CAD/CAM zirconia-based ceramic crown system
title_fullStr Evaluation of the marginal fit of a CAD/CAM zirconia-based ceramic crown system
title_full_unstemmed Evaluation of the marginal fit of a CAD/CAM zirconia-based ceramic crown system
title_sort evaluation of the marginal fit of a cad/cam zirconia-based ceramic crown system
publishDate 2022
url http://eprints.um.edu.my/41997/
_version_ 1781704580756668416