Peri-implant soft tissue integration of immediately loaded implants in posterior macaque mandible: a histomorphometric study

Background: Today, one critical goal in implant placement is the achievement of optimal soft tissue integration. Reports thus far have demonstrated successful soft tissue preservation in delayed loaded implants placed in anterior jaws. The aim of this study was to histomorphometrically examine the s...

Full description

Saved in:
Bibliographic Details
Main Authors: Siar, C.H., Toh, C.G., Romanos, G., Swaminathan, D., Ong, A.H., Yaacob, H., Nentwig, G.H.
Format: Article
Language:English
Published: 2003
Subjects:
Online Access:http://eprints.um.edu.my/4339/2/Peri-implant_soft_tissue_integration_of_immediately_loaded_implants_in_posterior_macaque_mandible_A_histomorphometric_study.pdf
http://eprints.um.edu.my/4339/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
Language: English
Description
Summary:Background: Today, one critical goal in implant placement is the achievement of optimal soft tissue integration. Reports thus far have demonstrated successful soft tissue preservation in delayed loaded implants placed in anterior jaws. The aim of this study was to histomorphometrically examine the soft tissues around immediately loaded implants placed in the macaque posterior mandible. Methods: Splinted crowns on screw-shaped titanium implants (8 mm length, 3.5 mm diameter) were utilized. Three implants each were placed in the premolar-molar edientulous mandibular segments of 6 adult monkeys (Macaca fascicularis); one side served as the control (delayed loading) and the other as the test sites (immediate loading). The animals were sacrificed after 3 months of loading. Histomorphometry of 6 soft tissue indices including the sulcus depth (SD), junctional epithelium (JE), connective tissue contact (CTC), biologic width (BW = SD + JE + CTC), DIM (distance between the implant top and coronal gingiva), and DIB (distance between the implant top and first implant-to-bone contact) was performed on non-decalcified sections. Results: No significant differences in the mean soft tissue scores (mm) between the test (SD = 0.68 +/- 0.63; JE = 1.71 +/- 1.04; CTC = 1.51 +/- 1.14; DIM = 2.27 +/- 1.18; DIB = 1.32 +/- 1.21; BW 3.9) and control (SD = 0.88 + 0.57; JE = 1.66 + 0.77; CTC 1.24 +/- 0.92; DIM = 2.38 +/- 0.81; DIB = 1.19 +/- 0.91; BW 3.78) groups were observed (P>0.01). Conclusion: These findings suggest that the dimensions of the peri-implant soft tissues were within the biologic range and were not influenced by immediate functional loading or posterior location of the implants in the macaque mandible.