Modeling of six-phase induction machine with two isolated neutrals under one open phase fault

Due to the COVID-19 pandemic, traditional laboratory sessions or face-To-face demonstrations for advanced electrical engineering level students in the field of power electronics and drives had to be substituted by e-learning to accommodate the new virtual teaching environment. This paper explains th...

Full description

Saved in:
Bibliographic Details
Main Authors: Munim, Wan Noraishah Wan Abdul, Che, Hang Seng, Tousizadeh, Mahdi, Baharom, Rahimi, Muhammad, Khairul Safuan
Format: Conference or Workshop Item
Published: Institute of Electrical and Electronics Engineers Inc. 2022
Subjects:
Online Access:http://eprints.um.edu.my/43645/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85143423185&doi=10.1109%2fIEACon55029.2022.9951719&partnerID=40&md5=06e5832ad571d07c53574f5f45684c6c
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.43645
record_format eprints
spelling my.um.eprints.436452025-02-18T03:33:53Z http://eprints.um.edu.my/43645/ Modeling of six-phase induction machine with two isolated neutrals under one open phase fault Munim, Wan Noraishah Wan Abdul Che, Hang Seng Tousizadeh, Mahdi Baharom, Rahimi Muhammad, Khairul Safuan TK Electrical engineering. Electronics Nuclear engineering Due to the COVID-19 pandemic, traditional laboratory sessions or face-To-face demonstrations for advanced electrical engineering level students in the field of power electronics and drives had to be substituted by e-learning to accommodate the new virtual teaching environment. This paper explains the operation of a symmetrical six-phase induction drive having two isolated neutrals configuration (2N) under one open phase fault (OPF) as a case study. The whole system, including the OPF, has been modeled in MATLAB Simulink which is intended for teaching and research purposes in the field of power electronics and drives. The aim of this paper is to elaborate the pre-and post-fault behaviour of the stator current, speed and torque. The machine model presented here is based on vector space decomposition (VSD) and controller using Indirect Rotor Field Oriented Control (IRFOC). In addition, this paper explains the external resistance used to initiate the OPF. The described MATLAB simulation helps the students to understand and observed the amplitude of stator current during pre-and post-fault conditions with respect to the mechanical loading. This model allows preliminary analysis for monitoring and comparison of machine performance. © 2022 IEEE. Institute of Electrical and Electronics Engineers Inc. 2022 Conference or Workshop Item PeerReviewed Munim, Wan Noraishah Wan Abdul and Che, Hang Seng and Tousizadeh, Mahdi and Baharom, Rahimi and Muhammad, Khairul Safuan (2022) Modeling of six-phase induction machine with two isolated neutrals under one open phase fault. In: 3rd IEEE Industrial Electronics and Applications Conference, IEACon 2022, 3-4 October 2022, Virtual, Online. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85143423185&doi=10.1109%2fIEACon55029.2022.9951719&partnerID=40&md5=06e5832ad571d07c53574f5f45684c6c
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Munim, Wan Noraishah Wan Abdul
Che, Hang Seng
Tousizadeh, Mahdi
Baharom, Rahimi
Muhammad, Khairul Safuan
Modeling of six-phase induction machine with two isolated neutrals under one open phase fault
description Due to the COVID-19 pandemic, traditional laboratory sessions or face-To-face demonstrations for advanced electrical engineering level students in the field of power electronics and drives had to be substituted by e-learning to accommodate the new virtual teaching environment. This paper explains the operation of a symmetrical six-phase induction drive having two isolated neutrals configuration (2N) under one open phase fault (OPF) as a case study. The whole system, including the OPF, has been modeled in MATLAB Simulink which is intended for teaching and research purposes in the field of power electronics and drives. The aim of this paper is to elaborate the pre-and post-fault behaviour of the stator current, speed and torque. The machine model presented here is based on vector space decomposition (VSD) and controller using Indirect Rotor Field Oriented Control (IRFOC). In addition, this paper explains the external resistance used to initiate the OPF. The described MATLAB simulation helps the students to understand and observed the amplitude of stator current during pre-and post-fault conditions with respect to the mechanical loading. This model allows preliminary analysis for monitoring and comparison of machine performance. © 2022 IEEE.
format Conference or Workshop Item
author Munim, Wan Noraishah Wan Abdul
Che, Hang Seng
Tousizadeh, Mahdi
Baharom, Rahimi
Muhammad, Khairul Safuan
author_facet Munim, Wan Noraishah Wan Abdul
Che, Hang Seng
Tousizadeh, Mahdi
Baharom, Rahimi
Muhammad, Khairul Safuan
author_sort Munim, Wan Noraishah Wan Abdul
title Modeling of six-phase induction machine with two isolated neutrals under one open phase fault
title_short Modeling of six-phase induction machine with two isolated neutrals under one open phase fault
title_full Modeling of six-phase induction machine with two isolated neutrals under one open phase fault
title_fullStr Modeling of six-phase induction machine with two isolated neutrals under one open phase fault
title_full_unstemmed Modeling of six-phase induction machine with two isolated neutrals under one open phase fault
title_sort modeling of six-phase induction machine with two isolated neutrals under one open phase fault
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2022
url http://eprints.um.edu.my/43645/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85143423185&doi=10.1109%2fIEACon55029.2022.9951719&partnerID=40&md5=06e5832ad571d07c53574f5f45684c6c
_version_ 1825160597603352576