Anodization and nonstructural surface characterizations of fabricated Ti–29Nb–13Ta–7.1Zr alloy for biomedical applications and its mechanical, wettability, tribological, and corrosion properties

Implants subjected to tribocorrosion release metallic ions and solid wear debris, which can cause a peri-implant disease, bone loss, and eventually implant loosening. TiO2 coatings have a wide application range owing to their biocompatibility. In this study, the Ti–29Nb–13Ta–7.1 Zr alloy was fabrica...

Full description

Saved in:
Bibliographic Details
Main Authors: Sarraf, Masoud, Musharavati, Farayi, Jaber, Fadi, Bushroa, A.R., Zalnezhad, Erfan, Nasor, Mohamed, Bae, Sungchul, Chowdhury, Muhammad, Dabbagh, Ali
Format: Article
Published: Elsevier 2024
Subjects:
Online Access:http://eprints.um.edu.my/44849/
https://doi.org/10.1016/j.matchemphys.2023.128825
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
id my.um.eprints.44849
record_format eprints
spelling my.um.eprints.448492024-11-15T08:44:28Z http://eprints.um.edu.my/44849/ Anodization and nonstructural surface characterizations of fabricated Ti–29Nb–13Ta–7.1Zr alloy for biomedical applications and its mechanical, wettability, tribological, and corrosion properties Sarraf, Masoud Musharavati, Farayi Jaber, Fadi Bushroa, A.R. Zalnezhad, Erfan Nasor, Mohamed Bae, Sungchul Chowdhury, Muhammad Dabbagh, Ali TK Electrical engineering. Electronics Nuclear engineering Implants subjected to tribocorrosion release metallic ions and solid wear debris, which can cause a peri-implant disease, bone loss, and eventually implant loosening. TiO2 coatings have a wide application range owing to their biocompatibility. In this study, the Ti–29Nb–13Ta–7.1 Zr alloy was fabricated using powder metallurgy technique. The samples were electrochemically oxidized to produce self-standing TiO2 nanotubular arrays followed by annealing for 1 h at 450 °C to improve their crystallinity. The prepared TiO2 coatings were characterized by SEM, X-ray diffraction, and EDX, and the wettability, tribomechanical characteristics, and corrosion behavior of bio-functionalized TiO2 nanotubes were investigated. Atomic force microscopy observations were conducted to examine wear scars, and the wear volume was measured via 2D profilometry. Microhardness and nanoindentation tests were performed to evaluate the mechanical characteristics of TiO2 nanotubes such as microhardness, nanohardness, and modulus of elasticity. The thickness and diameter of the observed TiO2 nanotubes are 2 μm and 90.94 nm, respectively. The obtained results revealed that the deposition of a biofunctionalized Ti/TiO2 nanotube layer enhanced the hydrophilicity, tribomechanical properties, and corrosion resistance of the Ti–29Nb–13Ta–7.1Zr alloy. The COF of Ti alloy was 0.51 and it decreased to 0.28 after anodization and annealing at 450 °C. The contact angle of the Ti sample was 79.9° and it decreased to 45.6° after annealing at 850 °C. However, after the anodic oxidation and annealing at 450 °C, the contact angle decreased to 45.6°. © 2023 Elsevier B.V. Elsevier 2024 Article PeerReviewed Sarraf, Masoud and Musharavati, Farayi and Jaber, Fadi and Bushroa, A.R. and Zalnezhad, Erfan and Nasor, Mohamed and Bae, Sungchul and Chowdhury, Muhammad and Dabbagh, Ali (2024) Anodization and nonstructural surface characterizations of fabricated Ti–29Nb–13Ta–7.1Zr alloy for biomedical applications and its mechanical, wettability, tribological, and corrosion properties. Materials Chemistry and Physics, 314. p. 128825. ISSN 0254-0584, DOI https://doi.org/10.1016/j.matchemphys.2023.128825 <https://doi.org/10.1016/j.matchemphys.2023.128825>. https://doi.org/10.1016/j.matchemphys.2023.128825 10.1016/j.matchemphys.2023.128825
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Sarraf, Masoud
Musharavati, Farayi
Jaber, Fadi
Bushroa, A.R.
Zalnezhad, Erfan
Nasor, Mohamed
Bae, Sungchul
Chowdhury, Muhammad
Dabbagh, Ali
Anodization and nonstructural surface characterizations of fabricated Ti–29Nb–13Ta–7.1Zr alloy for biomedical applications and its mechanical, wettability, tribological, and corrosion properties
description Implants subjected to tribocorrosion release metallic ions and solid wear debris, which can cause a peri-implant disease, bone loss, and eventually implant loosening. TiO2 coatings have a wide application range owing to their biocompatibility. In this study, the Ti–29Nb–13Ta–7.1 Zr alloy was fabricated using powder metallurgy technique. The samples were electrochemically oxidized to produce self-standing TiO2 nanotubular arrays followed by annealing for 1 h at 450 °C to improve their crystallinity. The prepared TiO2 coatings were characterized by SEM, X-ray diffraction, and EDX, and the wettability, tribomechanical characteristics, and corrosion behavior of bio-functionalized TiO2 nanotubes were investigated. Atomic force microscopy observations were conducted to examine wear scars, and the wear volume was measured via 2D profilometry. Microhardness and nanoindentation tests were performed to evaluate the mechanical characteristics of TiO2 nanotubes such as microhardness, nanohardness, and modulus of elasticity. The thickness and diameter of the observed TiO2 nanotubes are 2 μm and 90.94 nm, respectively. The obtained results revealed that the deposition of a biofunctionalized Ti/TiO2 nanotube layer enhanced the hydrophilicity, tribomechanical properties, and corrosion resistance of the Ti–29Nb–13Ta–7.1Zr alloy. The COF of Ti alloy was 0.51 and it decreased to 0.28 after anodization and annealing at 450 °C. The contact angle of the Ti sample was 79.9° and it decreased to 45.6° after annealing at 850 °C. However, after the anodic oxidation and annealing at 450 °C, the contact angle decreased to 45.6°. © 2023 Elsevier B.V.
format Article
author Sarraf, Masoud
Musharavati, Farayi
Jaber, Fadi
Bushroa, A.R.
Zalnezhad, Erfan
Nasor, Mohamed
Bae, Sungchul
Chowdhury, Muhammad
Dabbagh, Ali
author_facet Sarraf, Masoud
Musharavati, Farayi
Jaber, Fadi
Bushroa, A.R.
Zalnezhad, Erfan
Nasor, Mohamed
Bae, Sungchul
Chowdhury, Muhammad
Dabbagh, Ali
author_sort Sarraf, Masoud
title Anodization and nonstructural surface characterizations of fabricated Ti–29Nb–13Ta–7.1Zr alloy for biomedical applications and its mechanical, wettability, tribological, and corrosion properties
title_short Anodization and nonstructural surface characterizations of fabricated Ti–29Nb–13Ta–7.1Zr alloy for biomedical applications and its mechanical, wettability, tribological, and corrosion properties
title_full Anodization and nonstructural surface characterizations of fabricated Ti–29Nb–13Ta–7.1Zr alloy for biomedical applications and its mechanical, wettability, tribological, and corrosion properties
title_fullStr Anodization and nonstructural surface characterizations of fabricated Ti–29Nb–13Ta–7.1Zr alloy for biomedical applications and its mechanical, wettability, tribological, and corrosion properties
title_full_unstemmed Anodization and nonstructural surface characterizations of fabricated Ti–29Nb–13Ta–7.1Zr alloy for biomedical applications and its mechanical, wettability, tribological, and corrosion properties
title_sort anodization and nonstructural surface characterizations of fabricated ti–29nb–13ta–7.1zr alloy for biomedical applications and its mechanical, wettability, tribological, and corrosion properties
publisher Elsevier
publishDate 2024
url http://eprints.um.edu.my/44849/
https://doi.org/10.1016/j.matchemphys.2023.128825
_version_ 1816130421523480576