Energy use, energy savings and environmental analysis of industrial boilers and compressors

In this paper energy use , energy and bill savings, emission reduction and pay period using high efficient motor, variable speed drive by modulating speed of boiler and compressor has been estimated using energy audit data. It has been found that 68,923 MWh, 132,922 MWh, 78,769 MWh and 49,230 MWh of...

Full description

Saved in:
Bibliographic Details
Main Authors: Saidur, Rahman, Hasanuzzaman, M., Rahim, N.A.
Format: Article
Language:English
Published: International Journal of Thermal & Environmental Engineering 2010
Subjects:
Online Access:http://eprints.um.edu.my/6727/1/Energy_Use%2C_Energy_Savings_and_Environmental_Analysis_of_Industrial_Boilers_and_Compressors.pdf
http://eprints.um.edu.my/6727/
https://www.iasks.org/sites/default/files/ijtee20100101029036.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
Language: English
id my.um.eprints.6727
record_format eprints
spelling my.um.eprints.67272019-10-25T06:11:31Z http://eprints.um.edu.my/6727/ Energy use, energy savings and environmental analysis of industrial boilers and compressors Saidur, Rahman Hasanuzzaman, M. Rahim, N.A. TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery In this paper energy use , energy and bill savings, emission reduction and pay period using high efficient motor, variable speed drive by modulating speed of boiler and compressor has been estimated using energy audit data. It has been found that 68,923 MWh, 132,922 MWh, 78,769 MWh and 49,230 MWh of energy can be saved for 40, 60, 80 and 100 motor loadings, respectively for 20 speed reduction in the boiler system. Corresponding bill savings for the aforementioned energy savings have been found to be US 4,411,052, US 8,507,028, US 5,041,202, and US 43,150,751 for 40, 60, 80 and 100 motor loadings, respectively for 20 speed reduction in the boiler system. Energy savings and bill savings resulting from the use of high-efficiency motor in air compressor are 6703 MWh, 8251 MWh, and 10571 MWh, total energy, can be saved for 50, 75, and 100, motor loadings, respectively. Similarly, bill savings for the preceding amounts of energy savings are US 428,984, US 528,042 and US 676,538, respectively. It is also clear that the use of high efficiency motor and VSDs leads to substantial energy savings and an enormous reduction in emissions. International Journal of Thermal & Environmental Engineering 2010 Article PeerReviewed application/pdf en http://eprints.um.edu.my/6727/1/Energy_Use%2C_Energy_Savings_and_Environmental_Analysis_of_Industrial_Boilers_and_Compressors.pdf Saidur, Rahman and Hasanuzzaman, M. and Rahim, N.A. (2010) Energy use, energy savings and environmental analysis of industrial boilers and compressors. International Journal of Thermal & Environmental Engineering, 1 (1). pp. 29-36. ISSN 19237308 https://www.iasks.org/sites/default/files/ijtee20100101029036.pdf 10.5383/ijtee.01.01.005
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
spellingShingle TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
Saidur, Rahman
Hasanuzzaman, M.
Rahim, N.A.
Energy use, energy savings and environmental analysis of industrial boilers and compressors
description In this paper energy use , energy and bill savings, emission reduction and pay period using high efficient motor, variable speed drive by modulating speed of boiler and compressor has been estimated using energy audit data. It has been found that 68,923 MWh, 132,922 MWh, 78,769 MWh and 49,230 MWh of energy can be saved for 40, 60, 80 and 100 motor loadings, respectively for 20 speed reduction in the boiler system. Corresponding bill savings for the aforementioned energy savings have been found to be US 4,411,052, US 8,507,028, US 5,041,202, and US 43,150,751 for 40, 60, 80 and 100 motor loadings, respectively for 20 speed reduction in the boiler system. Energy savings and bill savings resulting from the use of high-efficiency motor in air compressor are 6703 MWh, 8251 MWh, and 10571 MWh, total energy, can be saved for 50, 75, and 100, motor loadings, respectively. Similarly, bill savings for the preceding amounts of energy savings are US 428,984, US 528,042 and US 676,538, respectively. It is also clear that the use of high efficiency motor and VSDs leads to substantial energy savings and an enormous reduction in emissions.
format Article
author Saidur, Rahman
Hasanuzzaman, M.
Rahim, N.A.
author_facet Saidur, Rahman
Hasanuzzaman, M.
Rahim, N.A.
author_sort Saidur, Rahman
title Energy use, energy savings and environmental analysis of industrial boilers and compressors
title_short Energy use, energy savings and environmental analysis of industrial boilers and compressors
title_full Energy use, energy savings and environmental analysis of industrial boilers and compressors
title_fullStr Energy use, energy savings and environmental analysis of industrial boilers and compressors
title_full_unstemmed Energy use, energy savings and environmental analysis of industrial boilers and compressors
title_sort energy use, energy savings and environmental analysis of industrial boilers and compressors
publisher International Journal of Thermal & Environmental Engineering
publishDate 2010
url http://eprints.um.edu.my/6727/1/Energy_Use%2C_Energy_Savings_and_Environmental_Analysis_of_Industrial_Boilers_and_Compressors.pdf
http://eprints.um.edu.my/6727/
https://www.iasks.org/sites/default/files/ijtee20100101029036.pdf
_version_ 1648736063599935488