Analysis of energy savings for rewinding and replacement of industrial motor
This study analyzed and estimated economic viability of introducing high efficiency motors compared to the rewind and standard motor in the industrial sector. Efficiency of a motor is degraded when it is rewound. This analysis identified that it is better to rewind a larger motor compared to a small...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2010
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/6765/1/Analysis_of_energy_savings_for_rewinding_and_replacement_of_industrial_motor.pdf http://eprints.um.edu.my/6765/ http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=5697596&tag=1 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaya |
Language: | English |
id |
my.um.eprints.6765 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.67652019-10-25T06:02:48Z http://eprints.um.edu.my/6765/ Analysis of energy savings for rewinding and replacement of industrial motor Hasanuzzaman, M. Rahim, N.A. Saidur, Rahman TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery This study analyzed and estimated economic viability of introducing high efficiency motors compared to the rewind and standard motor in the industrial sector. Efficiency of a motor is degraded when it is rewound. This analysis identified that it is better to rewind a larger motor compared to a smaller motor. It has been found that a high efficiency motor can save an average 5.5 of energy compared to a standard motor. In addition, payback period has been found to be reasonable when a motor is operated at 50 load. It has been estimated that 67,868 MWh/year energy and 4,343,531 US/year bill can be saved for introducing high efficient motors. The present study found that rewind motors of larger size and high efficiency motors are economically viable. 2010 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.um.edu.my/6765/1/Analysis_of_energy_savings_for_rewinding_and_replacement_of_industrial_motor.pdf Hasanuzzaman, M. and Rahim, N.A. and Saidur, Rahman (2010) Analysis of energy savings for rewinding and replacement of industrial motor. In: 2010 IEEE International Conference on Power and Energy, PECon2010, 2010, Kuala Lumpur. http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=5697596&tag=1 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery |
spellingShingle |
TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery Hasanuzzaman, M. Rahim, N.A. Saidur, Rahman Analysis of energy savings for rewinding and replacement of industrial motor |
description |
This study analyzed and estimated economic viability of introducing high efficiency motors compared to the rewind and standard motor in the industrial sector. Efficiency of a motor is degraded when it is rewound. This analysis identified that it is better to rewind a larger motor compared to a smaller motor. It has been found that a high efficiency motor can save an average 5.5 of energy compared to a standard motor. In addition, payback period has been found to be reasonable when a motor is operated at 50 load. It has been estimated that 67,868 MWh/year energy and 4,343,531 US/year bill can be saved for introducing high efficient motors. The present study found that rewind motors of larger size and high efficiency motors are economically viable. |
format |
Conference or Workshop Item |
author |
Hasanuzzaman, M. Rahim, N.A. Saidur, Rahman |
author_facet |
Hasanuzzaman, M. Rahim, N.A. Saidur, Rahman |
author_sort |
Hasanuzzaman, M. |
title |
Analysis of energy savings for rewinding and replacement of industrial motor |
title_short |
Analysis of energy savings for rewinding and replacement of industrial motor |
title_full |
Analysis of energy savings for rewinding and replacement of industrial motor |
title_fullStr |
Analysis of energy savings for rewinding and replacement of industrial motor |
title_full_unstemmed |
Analysis of energy savings for rewinding and replacement of industrial motor |
title_sort |
analysis of energy savings for rewinding and replacement of industrial motor |
publishDate |
2010 |
url |
http://eprints.um.edu.my/6765/1/Analysis_of_energy_savings_for_rewinding_and_replacement_of_industrial_motor.pdf http://eprints.um.edu.my/6765/ http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=5697596&tag=1 |
_version_ |
1648736068577525760 |