Analysis of energy savings for rewinding and replacement of industrial motor

This study analyzed and estimated economic viability of introducing high efficiency motors compared to the rewind and standard motor in the industrial sector. Efficiency of a motor is degraded when it is rewound. This analysis identified that it is better to rewind a larger motor compared to a small...

Full description

Saved in:
Bibliographic Details
Main Authors: Hasanuzzaman, M., Rahim, N.A., Saidur, Rahman
Format: Conference or Workshop Item
Language:English
Published: 2010
Subjects:
Online Access:http://eprints.um.edu.my/6765/1/Analysis_of_energy_savings_for_rewinding_and_replacement_of_industrial_motor.pdf
http://eprints.um.edu.my/6765/
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=5697596&tag=1
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaya
Language: English
id my.um.eprints.6765
record_format eprints
spelling my.um.eprints.67652019-10-25T06:02:48Z http://eprints.um.edu.my/6765/ Analysis of energy savings for rewinding and replacement of industrial motor Hasanuzzaman, M. Rahim, N.A. Saidur, Rahman TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery This study analyzed and estimated economic viability of introducing high efficiency motors compared to the rewind and standard motor in the industrial sector. Efficiency of a motor is degraded when it is rewound. This analysis identified that it is better to rewind a larger motor compared to a smaller motor. It has been found that a high efficiency motor can save an average 5.5 of energy compared to a standard motor. In addition, payback period has been found to be reasonable when a motor is operated at 50 load. It has been estimated that 67,868 MWh/year energy and 4,343,531 US/year bill can be saved for introducing high efficient motors. The present study found that rewind motors of larger size and high efficiency motors are economically viable. 2010 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.um.edu.my/6765/1/Analysis_of_energy_savings_for_rewinding_and_replacement_of_industrial_motor.pdf Hasanuzzaman, M. and Rahim, N.A. and Saidur, Rahman (2010) Analysis of energy savings for rewinding and replacement of industrial motor. In: 2010 IEEE International Conference on Power and Energy, PECon2010, 2010, Kuala Lumpur. http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=5697596&tag=1
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
spellingShingle TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
Hasanuzzaman, M.
Rahim, N.A.
Saidur, Rahman
Analysis of energy savings for rewinding and replacement of industrial motor
description This study analyzed and estimated economic viability of introducing high efficiency motors compared to the rewind and standard motor in the industrial sector. Efficiency of a motor is degraded when it is rewound. This analysis identified that it is better to rewind a larger motor compared to a smaller motor. It has been found that a high efficiency motor can save an average 5.5 of energy compared to a standard motor. In addition, payback period has been found to be reasonable when a motor is operated at 50 load. It has been estimated that 67,868 MWh/year energy and 4,343,531 US/year bill can be saved for introducing high efficient motors. The present study found that rewind motors of larger size and high efficiency motors are economically viable.
format Conference or Workshop Item
author Hasanuzzaman, M.
Rahim, N.A.
Saidur, Rahman
author_facet Hasanuzzaman, M.
Rahim, N.A.
Saidur, Rahman
author_sort Hasanuzzaman, M.
title Analysis of energy savings for rewinding and replacement of industrial motor
title_short Analysis of energy savings for rewinding and replacement of industrial motor
title_full Analysis of energy savings for rewinding and replacement of industrial motor
title_fullStr Analysis of energy savings for rewinding and replacement of industrial motor
title_full_unstemmed Analysis of energy savings for rewinding and replacement of industrial motor
title_sort analysis of energy savings for rewinding and replacement of industrial motor
publishDate 2010
url http://eprints.um.edu.my/6765/1/Analysis_of_energy_savings_for_rewinding_and_replacement_of_industrial_motor.pdf
http://eprints.um.edu.my/6765/
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=5697596&tag=1
_version_ 1648736068577525760