ABSTRACT Mechanism of power system operations become more complex due to the increasing load demand and which lead to increased pressure and high risk to the transmission line. Therefore power system operation and stability become less safe due to unexpected congestion and voltage violations. In ad...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
Praise Worthy Prize
2012
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/7829/ http://connection.ebscohost.com/c/articles/84994994/comparison-facts-device-installation-power-transmission-system |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaya |
id |
my.um.eprints.7829 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.78292019-10-24T08:07:01Z http://eprints.um.edu.my/7829/ Comparison of FACTS device installation in power transmission system Jumaat, S.A. Musirin, I. Othman, M.M. Mokhlis, Hazlie TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering ABSTRACT Mechanism of power system operations become more complex due to the increasing load demand and which lead to increased pressure and high risk to the transmission line. Therefore power system operation and stability become less safe due to unexpected congestion and voltage violations. In additional, new transmission line is considered one of the solutions to provide a stable operation it is more secure to the power system. However it is more expensive and time consuming which also need to address the political and environmental issues. One of the alternatives which can be employed is the use of Flexible AC Transmission System (FACTS). This paper presents a study on optimal location and sizing of FACTS device based on Particle Swarm Optimization for minimization of transmission losses, voltage profile improvement which takes into account cost of installation. In this study, Static Var Compensator (SVC) and Thyristor Controlled Series Compensator (TCSC) are chosen as the compensation device. Validation through the implementation on the IEEE 30-bus system indicated that PSO is feasible to achieve the task. In simulation results are compared with those obtained from Evolutionary Programming (EP) and Artificial Immune System (AIS) technique in the attempt to highlight its merit. Praise Worthy Prize 2012 Article PeerReviewed Jumaat, S.A. and Musirin, I. and Othman, M.M. and Mokhlis, Hazlie (2012) Comparison of FACTS device installation in power transmission system. International Review on Modelling and Simulations, 5 (4). p. 1679. ISSN 1974-9821 http://connection.ebscohost.com/c/articles/84994994/comparison-facts-device-installation-power-transmission-system |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering Jumaat, S.A. Musirin, I. Othman, M.M. Mokhlis, Hazlie Comparison of FACTS device installation in power transmission system |
description |
ABSTRACT Mechanism of power system operations become more complex due to the increasing load demand and which lead to increased pressure and high risk to the transmission line. Therefore power system operation and stability become less safe due to unexpected congestion and voltage violations. In additional, new transmission line is considered one of the solutions to provide a stable operation it is more secure to the power system. However it is more expensive and time consuming which also need to address the political and environmental issues. One of the alternatives which can be employed is the use of Flexible AC Transmission System (FACTS). This paper presents a study on optimal location and sizing of FACTS device based on Particle Swarm Optimization for minimization of transmission losses, voltage profile improvement which takes into account cost of installation. In this study, Static Var Compensator (SVC) and Thyristor Controlled Series Compensator (TCSC) are chosen as the compensation device. Validation through the implementation on the IEEE 30-bus system indicated that PSO is feasible to achieve the task. In simulation results are compared with those obtained from Evolutionary Programming (EP) and Artificial Immune System (AIS) technique in the attempt to highlight its merit. |
format |
Article |
author |
Jumaat, S.A. Musirin, I. Othman, M.M. Mokhlis, Hazlie |
author_facet |
Jumaat, S.A. Musirin, I. Othman, M.M. Mokhlis, Hazlie |
author_sort |
Jumaat, S.A. |
title |
Comparison of FACTS device installation in power transmission system |
title_short |
Comparison of FACTS device installation in power transmission system |
title_full |
Comparison of FACTS device installation in power transmission system |
title_fullStr |
Comparison of FACTS device installation in power transmission system |
title_full_unstemmed |
Comparison of FACTS device installation in power transmission system |
title_sort |
comparison of facts device installation in power transmission system |
publisher |
Praise Worthy Prize |
publishDate |
2012 |
url |
http://eprints.um.edu.my/7829/ http://connection.ebscohost.com/c/articles/84994994/comparison-facts-device-installation-power-transmission-system |
_version_ |
1648736080879419392 |