Thermal Analysis On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate

Numerical analysis of thermal enhancement for a single Proton Exchange Membrane Fuel Cell (PEMFC) cooling plate is presented in this paper. A low concentration of Al2O3 in Water - Ethylene Glycol mixtures was used as coolant in 220mm x 300mm cooling plate with 22 parallel mini channels of 1 x 5 x...

Full description

Saved in:
Bibliographic Details
Main Authors: Irnie, Zakaria, W. A. N. W., Mohamed, A. M. I., Mamat, R., Saidur, Azmi, W. H., R., Mamat, K. I., Sainan, H., Ismail
Format: Article
Language:English
Published: Elsevier Ltd 2015
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/11676/1/Zakaria%20et%20al.%20EP%202015b%20Numerical%20HT.pdf
http://umpir.ump.edu.my/id/eprint/11676/
http://dx.doi.org/10.1016/j.egypro.2015.11.475
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.11676
record_format eprints
spelling my.ump.umpir.116762018-10-16T03:20:21Z http://umpir.ump.edu.my/id/eprint/11676/ Thermal Analysis On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate Irnie, Zakaria W. A. N. W., Mohamed A. M. I., Mamat R., Saidur Azmi, W. H. R., Mamat K. I., Sainan H., Ismail TJ Mechanical engineering and machinery Numerical analysis of thermal enhancement for a single Proton Exchange Membrane Fuel Cell (PEMFC) cooling plate is presented in this paper. A low concentration of Al2O3 in Water - Ethylene Glycol mixtures was used as coolant in 220mm x 300mm cooling plate with 22 parallel mini channels of 1 x 5 x 100mm. This cooling plate mimicked conventional PEMFC cooling plate as it was made of carbon graphite. Large header was added to have an even velocity distribution across all Re number studied. The cooling plate was subjected to a constant heat flux of 100W that represented the artificial heat load of a single cell. Al2O3 nano particle volume % concentration of 0.1 and 0.5 vol was dispersed in 50:50 (water: Ethylene Glycol) mixtures. The effect of different flow rates to heat transfer enhancement and fluid flow in Re range of 30 to 150 were observed. The result showed that thermal performance has improved by 7.3 and 4.6% for 0.5 and 0.1 vol % Al2O3 consecutively in 50:50 (water:EG) as compared to base fluid of 50:50 (water:EG). It is shown that the higher vol % concentration of Al2O3 the better the heat transfer enhancement but at the expense of higher pumping power required as much as 0.04W due to increase in pressure drop. The positive thermal results implied that Al2O3 nanofluid is a potential candidate for future applications in PEM fuel cell thermal management. Elsevier Ltd 2015 Article PeerReviewed application/pdf en cc_by_nc_nd http://umpir.ump.edu.my/id/eprint/11676/1/Zakaria%20et%20al.%20EP%202015b%20Numerical%20HT.pdf Irnie, Zakaria and W. A. N. W., Mohamed and A. M. I., Mamat and R., Saidur and Azmi, W. H. and R., Mamat and K. I., Sainan and H., Ismail (2015) Thermal Analysis On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate. Energy Procedia, 79. pp. 259-264. ISSN 1876-6102 http://dx.doi.org/10.1016/j.egypro.2015.11.475 DOI: 10.1016/j.egypro.2015.11.475
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Irnie, Zakaria
W. A. N. W., Mohamed
A. M. I., Mamat
R., Saidur
Azmi, W. H.
R., Mamat
K. I., Sainan
H., Ismail
Thermal Analysis On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate
description Numerical analysis of thermal enhancement for a single Proton Exchange Membrane Fuel Cell (PEMFC) cooling plate is presented in this paper. A low concentration of Al2O3 in Water - Ethylene Glycol mixtures was used as coolant in 220mm x 300mm cooling plate with 22 parallel mini channels of 1 x 5 x 100mm. This cooling plate mimicked conventional PEMFC cooling plate as it was made of carbon graphite. Large header was added to have an even velocity distribution across all Re number studied. The cooling plate was subjected to a constant heat flux of 100W that represented the artificial heat load of a single cell. Al2O3 nano particle volume % concentration of 0.1 and 0.5 vol was dispersed in 50:50 (water: Ethylene Glycol) mixtures. The effect of different flow rates to heat transfer enhancement and fluid flow in Re range of 30 to 150 were observed. The result showed that thermal performance has improved by 7.3 and 4.6% for 0.5 and 0.1 vol % Al2O3 consecutively in 50:50 (water:EG) as compared to base fluid of 50:50 (water:EG). It is shown that the higher vol % concentration of Al2O3 the better the heat transfer enhancement but at the expense of higher pumping power required as much as 0.04W due to increase in pressure drop. The positive thermal results implied that Al2O3 nanofluid is a potential candidate for future applications in PEM fuel cell thermal management.
format Article
author Irnie, Zakaria
W. A. N. W., Mohamed
A. M. I., Mamat
R., Saidur
Azmi, W. H.
R., Mamat
K. I., Sainan
H., Ismail
author_facet Irnie, Zakaria
W. A. N. W., Mohamed
A. M. I., Mamat
R., Saidur
Azmi, W. H.
R., Mamat
K. I., Sainan
H., Ismail
author_sort Irnie, Zakaria
title Thermal Analysis On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate
title_short Thermal Analysis On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate
title_full Thermal Analysis On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate
title_fullStr Thermal Analysis On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate
title_full_unstemmed Thermal Analysis On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate
title_sort thermal analysis on heat transfer enhancement and fluid flow for low concentration of al2o3 water - ethylene glycol mixture nanofluid in a single pemfc cooling plate
publisher Elsevier Ltd
publishDate 2015
url http://umpir.ump.edu.my/id/eprint/11676/1/Zakaria%20et%20al.%20EP%202015b%20Numerical%20HT.pdf
http://umpir.ump.edu.my/id/eprint/11676/
http://dx.doi.org/10.1016/j.egypro.2015.11.475
_version_ 1643666719937396736