Insulin Sensitivity and Sepsis Score: A Correlation between Model-based Metric and Sepsis Scoring System in Critically Ill Patients
Sepsis is highly correlated with mortality and morbidity. Sepsis is a clinical condition demarcated as the existence of infection and systemic inflammatory response syndrome, SIRS. Confirmation of infection requires a blood culture test, which requires incubation, and thus results take at least 48 h...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Elsevier
2017
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/14155/1/1-s2.0-S1746809416301008-main.pdf http://umpir.ump.edu.my/id/eprint/14155/7/Insulin%20sensitivity%20and%20sepsis%20score-%20A%20correlation%20between%20model-based%20metric%20and%20sepsis%20scoring%20system%20in%20critically%20ill%20patients%201.pdf http://umpir.ump.edu.my/id/eprint/14155/ http://dx.doi.org/10.1016/j.bspc.2016.08.005 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English English |
id |
my.ump.umpir.14155 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.141552018-11-30T01:55:13Z http://umpir.ump.edu.my/id/eprint/14155/ Insulin Sensitivity and Sepsis Score: A Correlation between Model-based Metric and Sepsis Scoring System in Critically Ill Patients Fatanah, M. Suhaimi Chase, J. Geoffrey Pretty, Christopher G. Shaw, Geoffrey M. Normy Norfiza, A. Razak Ummu Kulthum, Jamaludin QA Mathematics RZ Other systems of medicine TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery Sepsis is highly correlated with mortality and morbidity. Sepsis is a clinical condition demarcated as the existence of infection and systemic inflammatory response syndrome, SIRS. Confirmation of infection requires a blood culture test, which requires incubation, and thus results take at least 48 h for a syndrome that requires early direct treatment. Since sepsis has a strong inflammatory component, it is hypothesized that metabolic markers affected by inflammation, such as insulin sensitivity, might provide a metric for more rapid, real-time diagnosis. This study uses clinical data from 30 sepsis patients (7624 h in ICU) of whom 60% are male. Median age and median Apache II score are 63 years and 19, respectively. Model-identified insulin sensitivity (SI) profiles were obtained for each patient, and insulin sensitivity and its hourly changes were correlated with modified hourly sepsis scores (SSH1). SI profiles and values were similar across the cohort. The sepsis score is highly variable and changes rapidly. The modified hourly sepsis score, SSH1, shows a better relation with insulin sensitivity due to less fluctuation in the SIRS element. Median SI and median SI of the cohort is 0.4193e-3 and 0.004253e-3 L/mU.min, respectively. Additionally, median SI are 4.392 × 10−4 L/mU min (SSH1 = 0), 4.153 × 10−4 L/mU min (SSH1 = 1), 3.752 × 10−4 L/mU min (SSH1 = 2) and 2.353 × 10−4 L/mU min (SSH1 = 3). Significant relationship between insulin sensitivity across different SSH1 groups was observed (p < 0.05) even when corrected for multiple comparisons. CDF of SI indicates that insulin sensitivity is more significant when comparing an hourly sepsis score at a very distinguished level. Elsevier 2017 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/14155/1/1-s2.0-S1746809416301008-main.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/14155/7/Insulin%20sensitivity%20and%20sepsis%20score-%20A%20correlation%20between%20model-based%20metric%20and%20sepsis%20scoring%20system%20in%20critically%20ill%20patients%201.pdf Fatanah, M. Suhaimi and Chase, J. Geoffrey and Pretty, Christopher G. and Shaw, Geoffrey M. and Normy Norfiza, A. Razak and Ummu Kulthum, Jamaludin (2017) Insulin Sensitivity and Sepsis Score: A Correlation between Model-based Metric and Sepsis Scoring System in Critically Ill Patients. Biomedical Signal Processing and Control, 32. pp. 112-123. ISSN 1746-8094 http://dx.doi.org/10.1016/j.bspc.2016.08.005 DOI: 10.1016/j.bspc.2016.08.005 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English English |
topic |
QA Mathematics RZ Other systems of medicine TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery |
spellingShingle |
QA Mathematics RZ Other systems of medicine TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery Fatanah, M. Suhaimi Chase, J. Geoffrey Pretty, Christopher G. Shaw, Geoffrey M. Normy Norfiza, A. Razak Ummu Kulthum, Jamaludin Insulin Sensitivity and Sepsis Score: A Correlation between Model-based Metric and Sepsis Scoring System in Critically Ill Patients |
description |
Sepsis is highly correlated with mortality and morbidity. Sepsis is a clinical condition demarcated as the existence of infection and systemic inflammatory response syndrome, SIRS. Confirmation of infection requires a blood culture test, which requires incubation, and thus results take at least 48 h for a syndrome that requires early direct treatment. Since sepsis has a strong inflammatory component, it is hypothesized that metabolic markers affected by inflammation, such as insulin sensitivity, might provide a metric for more rapid, real-time diagnosis. This study uses clinical data from 30 sepsis patients (7624 h in ICU) of whom 60% are male. Median age and median Apache II score are 63 years and 19, respectively. Model-identified insulin sensitivity (SI) profiles were obtained for each patient, and insulin sensitivity and its hourly changes were correlated with modified hourly sepsis scores (SSH1). SI profiles and values were similar across the cohort. The sepsis score is highly variable and changes rapidly. The modified
hourly sepsis score, SSH1, shows a better relation with insulin sensitivity due to less fluctuation in the
SIRS element. Median SI and median SI of the cohort is 0.4193e-3 and 0.004253e-3 L/mU.min, respectively.
Additionally, median SI are 4.392 × 10−4 L/mU min (SSH1 = 0), 4.153 × 10−4 L/mU min (SSH1 = 1), 3.752 × 10−4 L/mU min (SSH1 = 2) and 2.353 × 10−4 L/mU min (SSH1 = 3). Significant relationship between insulin sensitivity across different SSH1 groups was observed (p < 0.05) even when corrected for multiple comparisons. CDF of SI indicates that insulin sensitivity is more significant when comparing an hourly sepsis score at a very distinguished level.
|
format |
Article |
author |
Fatanah, M. Suhaimi Chase, J. Geoffrey Pretty, Christopher G. Shaw, Geoffrey M. Normy Norfiza, A. Razak Ummu Kulthum, Jamaludin |
author_facet |
Fatanah, M. Suhaimi Chase, J. Geoffrey Pretty, Christopher G. Shaw, Geoffrey M. Normy Norfiza, A. Razak Ummu Kulthum, Jamaludin |
author_sort |
Fatanah, M. Suhaimi |
title |
Insulin Sensitivity and Sepsis Score: A Correlation between
Model-based Metric and Sepsis Scoring System in Critically Ill Patients |
title_short |
Insulin Sensitivity and Sepsis Score: A Correlation between
Model-based Metric and Sepsis Scoring System in Critically Ill Patients |
title_full |
Insulin Sensitivity and Sepsis Score: A Correlation between
Model-based Metric and Sepsis Scoring System in Critically Ill Patients |
title_fullStr |
Insulin Sensitivity and Sepsis Score: A Correlation between
Model-based Metric and Sepsis Scoring System in Critically Ill Patients |
title_full_unstemmed |
Insulin Sensitivity and Sepsis Score: A Correlation between
Model-based Metric and Sepsis Scoring System in Critically Ill Patients |
title_sort |
insulin sensitivity and sepsis score: a correlation between
model-based metric and sepsis scoring system in critically ill patients |
publisher |
Elsevier |
publishDate |
2017 |
url |
http://umpir.ump.edu.my/id/eprint/14155/1/1-s2.0-S1746809416301008-main.pdf http://umpir.ump.edu.my/id/eprint/14155/7/Insulin%20sensitivity%20and%20sepsis%20score-%20A%20correlation%20between%20model-based%20metric%20and%20sepsis%20scoring%20system%20in%20critically%20ill%20patients%201.pdf http://umpir.ump.edu.my/id/eprint/14155/ http://dx.doi.org/10.1016/j.bspc.2016.08.005 |
_version_ |
1643667355749842944 |