Sonication Time Effect towards Stability of Al2O3/PAG and SiO2/PAG Nanolubricants
Ultrasonication is the act of applying sound force to agitate particles in a sample with the frequency of more than 20 kHz. It is an external vibration induced during preparation of nanolubricant that helps the particles to overcome the van der Waals force bonding. Nanolubricant prepared is intended...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Mechanical Engineering, Universiti Teknologi MARA (UiTM), Malaysia.
2018
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/18493/1/Sonication%20Time%20Effect%20Towards%20Stability-fkm-2018.pdf http://umpir.ump.edu.my/id/eprint/18493/ http://jmeche.com/wp-content/uploads/bsk-pdf-manager/2_SI_5_1_ID_117_302.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang Al-Sultan Abdullah |
Language: | English |
id |
my.ump.umpir.18493 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.184932019-10-17T08:11:57Z http://umpir.ump.edu.my/id/eprint/18493/ Sonication Time Effect towards Stability of Al2O3/PAG and SiO2/PAG Nanolubricants A. A. M., Redhwan W. H., Azmi Nurul Nadia, Mohd Zawawi M. Z., Sharif R., Mamat T Technology (General) TJ Mechanical engineering and machinery Ultrasonication is the act of applying sound force to agitate particles in a sample with the frequency of more than 20 kHz. It is an external vibration induced during preparation of nanolubricant that helps the particles to overcome the van der Waals force bonding. Nanolubricant prepared is intended to be used in automotive air conditioning (AAC) system to improve its performance. In this work, stability Polyalkylene glycol (PAG) and SiOi/PAG nanolubricants of 0.2 % volume concentrations with different sonication lime were investigated. Five samples for each nanolubricant were prepared by two-step method process with variation of sonication time from zero to two hours' time with half an hour interval. The stability tests were done by visual sedimentation and UV-vis spectrometer. The optimum sonication time found to be one and half hours and two hours for AI2O3/PAG and SiOi/PAG nanolubricants respectively. Both nanolubricants were found stable for more than two weeks 'period. Faculty of Mechanical Engineering, Universiti Teknologi MARA (UiTM), Malaysia. 2018-08 Article PeerReviewed text en http://umpir.ump.edu.my/id/eprint/18493/1/Sonication%20Time%20Effect%20Towards%20Stability-fkm-2018.pdf A. A. M., Redhwan and W. H., Azmi and Nurul Nadia, Mohd Zawawi and M. Z., Sharif and R., Mamat (2018) Sonication Time Effect towards Stability of Al2O3/PAG and SiO2/PAG Nanolubricants. Journal of Mechanical Engineering, SI 5 (1). pp. 14-27. ISSN 1823-5514. (Published) http://jmeche.com/wp-content/uploads/bsk-pdf-manager/2_SI_5_1_ID_117_302.pdf |
institution |
Universiti Malaysia Pahang Al-Sultan Abdullah |
building |
UMPSA Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang Al-Sultan Abdullah |
content_source |
UMPSA Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
T Technology (General) TJ Mechanical engineering and machinery |
spellingShingle |
T Technology (General) TJ Mechanical engineering and machinery A. A. M., Redhwan W. H., Azmi Nurul Nadia, Mohd Zawawi M. Z., Sharif R., Mamat Sonication Time Effect towards Stability of Al2O3/PAG and SiO2/PAG Nanolubricants |
description |
Ultrasonication is the act of applying sound force to agitate particles in a sample with the frequency of more than 20 kHz. It is an external vibration induced during preparation of nanolubricant that helps the particles to overcome the van der Waals force bonding. Nanolubricant prepared is intended to be used in automotive air conditioning (AAC) system to improve its performance. In this work, stability Polyalkylene glycol (PAG) and SiOi/PAG nanolubricants of 0.2 % volume concentrations with different sonication lime were investigated. Five samples for each nanolubricant were prepared by two-step method process with variation of sonication time from zero to two hours' time with half an hour interval. The stability tests were done by visual sedimentation and UV-vis spectrometer. The optimum sonication time found to be one and half hours and two hours for AI2O3/PAG and SiOi/PAG nanolubricants respectively. Both nanolubricants were found stable for more than two weeks 'period. |
format |
Article |
author |
A. A. M., Redhwan W. H., Azmi Nurul Nadia, Mohd Zawawi M. Z., Sharif R., Mamat |
author_facet |
A. A. M., Redhwan W. H., Azmi Nurul Nadia, Mohd Zawawi M. Z., Sharif R., Mamat |
author_sort |
A. A. M., Redhwan |
title |
Sonication Time Effect towards Stability of Al2O3/PAG and SiO2/PAG Nanolubricants |
title_short |
Sonication Time Effect towards Stability of Al2O3/PAG and SiO2/PAG Nanolubricants |
title_full |
Sonication Time Effect towards Stability of Al2O3/PAG and SiO2/PAG Nanolubricants |
title_fullStr |
Sonication Time Effect towards Stability of Al2O3/PAG and SiO2/PAG Nanolubricants |
title_full_unstemmed |
Sonication Time Effect towards Stability of Al2O3/PAG and SiO2/PAG Nanolubricants |
title_sort |
sonication time effect towards stability of al2o3/pag and sio2/pag nanolubricants |
publisher |
Faculty of Mechanical Engineering, Universiti Teknologi MARA (UiTM), Malaysia. |
publishDate |
2018 |
url |
http://umpir.ump.edu.my/id/eprint/18493/1/Sonication%20Time%20Effect%20Towards%20Stability-fkm-2018.pdf http://umpir.ump.edu.my/id/eprint/18493/ http://jmeche.com/wp-content/uploads/bsk-pdf-manager/2_SI_5_1_ID_117_302.pdf |
_version_ |
1822918752393494528 |