Development of an Electronic Kit for detecting asthma in Human Respiratory System
In this paper, a prototype of a carbon dioxide (CO2) measurement device is designed to detect and used to monitor asthma patients. Nowadays, capnogram device is widely used in monitoring asthma and asthma related medical services. However, capnogram is very costly and unaffordable for patient especi...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IOP Publishing
2018
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/20878/1/Development%20of%20an%20Electronic%20Kit%20for%20detecting%20asthma%20in%20human%20respiratory%20system1.pdf http://umpir.ump.edu.my/id/eprint/20878/ https://doi.org/10.1088/1757-899X/319/1/012040 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English |
id |
my.ump.umpir.20878 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.208782018-08-08T06:09:01Z http://umpir.ump.edu.my/id/eprint/20878/ Development of an Electronic Kit for detecting asthma in Human Respiratory System Hong, Cheow Shek Ahmad Shahrizan, Abdul Ghani Ismail, Mohd Khairuddin RZ Other systems of medicine T Technology (General) TD Environmental technology. Sanitary engineering TK Electrical engineering. Electronics Nuclear engineering TS Manufactures In this paper, a prototype of a carbon dioxide (CO2) measurement device is designed to detect and used to monitor asthma patients. Nowadays, capnogram device is widely used in monitoring asthma and asthma related medical services. However, capnogram is very costly and unaffordable for patient especially those who are in low income household. Thus, the proposed device is cost effective, affordable, and produced to detect and monitor the severity of asthma. Meanwhile, flow meter will cause patient to have chest pain as they needed maximum effort to blow in the device. To overcome these limitations, this prototype electronic kit is easy to use and suitable for all range patients. This prototype electronic kit consists of MH-Z14A carbon dioxide (CO2) sensor to detect the concentration of carbon dioxide from the user exhaled air. Arduinomicrocontroller is used to process the data while TFT Display shield is applied for data presentation. In addition, HC-06 Bluetooth module is used to communicate with PC for further analysis of the captured graph. This device was tested with 3 asthmatics and 3 normal users. The results showed that asthmatic user has a different graph pattern compared with normal user and these graphs are clearly differentiated on the device TFT screen. Asthmatic user produces “shark fin”-like pattern whereas normal user produces “square wave”-like pattern. This device has successfully produced distinguished-patterns difference between asthmatic and normal user; therefore, it is suitable for asthma monitoring. IOP Publishing 2018-03-21 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/20878/1/Development%20of%20an%20Electronic%20Kit%20for%20detecting%20asthma%20in%20human%20respiratory%20system1.pdf Hong, Cheow Shek and Ahmad Shahrizan, Abdul Ghani and Ismail, Mohd Khairuddin (2018) Development of an Electronic Kit for detecting asthma in Human Respiratory System. In: 4th Asia Pacific Conference on Manufacturing Systems and the 3rd International Manufacturing Engineering Conference, APCOMS-iMEC 2017, 7-8 December 2017 , Yogyakarta, Indonesia. pp. 1-8., 319 (1). ISSN 1757-8981 (Print); 1757-899X (Online) https://doi.org/10.1088/1757-899X/319/1/012040 10.1088/1757-899X/319/1/012040 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
RZ Other systems of medicine T Technology (General) TD Environmental technology. Sanitary engineering TK Electrical engineering. Electronics Nuclear engineering TS Manufactures |
spellingShingle |
RZ Other systems of medicine T Technology (General) TD Environmental technology. Sanitary engineering TK Electrical engineering. Electronics Nuclear engineering TS Manufactures Hong, Cheow Shek Ahmad Shahrizan, Abdul Ghani Ismail, Mohd Khairuddin Development of an Electronic Kit for detecting asthma in Human Respiratory System |
description |
In this paper, a prototype of a carbon dioxide (CO2) measurement device is designed to detect and used to monitor asthma patients. Nowadays, capnogram device is widely used in monitoring asthma and asthma related medical services. However, capnogram is very costly and unaffordable for patient especially those who are in low income household. Thus, the proposed device is cost effective, affordable, and produced to detect and monitor the severity of asthma. Meanwhile, flow meter will cause patient to have chest pain as they needed maximum effort to blow in the device. To overcome these limitations, this prototype electronic kit is easy to use and suitable for all range patients. This prototype electronic kit consists of MH-Z14A carbon dioxide (CO2) sensor to detect the concentration of carbon dioxide from the user exhaled air. Arduinomicrocontroller is used to process the data while TFT Display shield is applied for data presentation. In addition, HC-06 Bluetooth module is used to communicate with PC for further analysis of the captured graph. This device was tested with 3 asthmatics and 3 normal users. The results showed that asthmatic user has a different graph pattern compared with normal user and these graphs are clearly differentiated on the device TFT screen. Asthmatic user produces “shark fin”-like pattern whereas normal user produces “square wave”-like pattern. This device has successfully produced distinguished-patterns difference between asthmatic and normal user; therefore, it is suitable for asthma monitoring. |
format |
Conference or Workshop Item |
author |
Hong, Cheow Shek Ahmad Shahrizan, Abdul Ghani Ismail, Mohd Khairuddin |
author_facet |
Hong, Cheow Shek Ahmad Shahrizan, Abdul Ghani Ismail, Mohd Khairuddin |
author_sort |
Hong, Cheow Shek |
title |
Development of an Electronic Kit for detecting asthma in Human Respiratory System |
title_short |
Development of an Electronic Kit for detecting asthma in Human Respiratory System |
title_full |
Development of an Electronic Kit for detecting asthma in Human Respiratory System |
title_fullStr |
Development of an Electronic Kit for detecting asthma in Human Respiratory System |
title_full_unstemmed |
Development of an Electronic Kit for detecting asthma in Human Respiratory System |
title_sort |
development of an electronic kit for detecting asthma in human respiratory system |
publisher |
IOP Publishing |
publishDate |
2018 |
url |
http://umpir.ump.edu.my/id/eprint/20878/1/Development%20of%20an%20Electronic%20Kit%20for%20detecting%20asthma%20in%20human%20respiratory%20system1.pdf http://umpir.ump.edu.my/id/eprint/20878/ https://doi.org/10.1088/1757-899X/319/1/012040 |
_version_ |
1643668991348047872 |