Usage of parallel manipulator for external chest compressions during cardiopulmonary resuscitation - an experimental study on feedback manikin
Uninterrupted chest compressions plays a key role in the survival of the cardiac arrest patient during cardiopulmonary resuscitation. For this purpose, a parallel manipulator operated by the pneumatic air pressure is designed, and the experiments were conducted on the Ambu feedback manikin by varyin...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IAEME Publication
2018
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/22598/1/Usage%20of%20parallel%20manipulator%20for%20external%20chest%20compressions%20during%20cardiopulmonary%20resuscitation.pdf http://umpir.ump.edu.my/id/eprint/22598/ https://www.iaeme.com/MasterAdmin/UploadFolder/IJMET_09_09_108/IJMET_09_09_108.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English |
id |
my.ump.umpir.22598 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.225982018-12-06T06:56:41Z http://umpir.ump.edu.my/id/eprint/22598/ Usage of parallel manipulator for external chest compressions during cardiopulmonary resuscitation - an experimental study on feedback manikin Rao, G. Babu Kumar, M. Wilson Sahu, Mona Rao, G. Anada Manoj Kumar, Nallapaneni TK Electrical engineering. Electronics Nuclear engineering Uninterrupted chest compressions plays a key role in the survival of the cardiac arrest patient during cardiopulmonary resuscitation. For this purpose, a parallel manipulator operated by the pneumatic air pressure is designed, and the experiments were conducted on the Ambu feedback manikin by varying chest stiffness in the manikin for every bar of the pneumatic air pressure that is kept constant at different pressures ranging from 4 to 7.5 bar. From the experimental investigations, it is found that the obtained results were highly satisfied the standards of American Heart Association. It is observed that, American Heart Association guidelines were met, when the designed unit is operated under a pressure of 6 bar or more for the range of chest stiffness from 6 to 6.5 N/mm. IAEME Publication 2018-09 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/22598/1/Usage%20of%20parallel%20manipulator%20for%20external%20chest%20compressions%20during%20cardiopulmonary%20resuscitation.pdf Rao, G. Babu and Kumar, M. Wilson and Sahu, Mona and Rao, G. Anada and Manoj Kumar, Nallapaneni (2018) Usage of parallel manipulator for external chest compressions during cardiopulmonary resuscitation - an experimental study on feedback manikin. International Journal of Mechanical Engineering and Technology (IJMET), 9 (9). pp. 990-998. ISSN 0976-6340 (Print); 0976-6359 (Online) https://www.iaeme.com/MasterAdmin/UploadFolder/IJMET_09_09_108/IJMET_09_09_108.pdf |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Rao, G. Babu Kumar, M. Wilson Sahu, Mona Rao, G. Anada Manoj Kumar, Nallapaneni Usage of parallel manipulator for external chest compressions during cardiopulmonary resuscitation - an experimental study on feedback manikin |
description |
Uninterrupted chest compressions plays a key role in the survival of the cardiac arrest patient during cardiopulmonary resuscitation. For this purpose, a parallel manipulator operated by the pneumatic air pressure is designed, and the experiments were conducted on the Ambu feedback manikin by varying chest stiffness in the manikin for every bar of the pneumatic air pressure that is kept constant at different pressures ranging from 4 to 7.5 bar. From the experimental investigations, it is found that the obtained results were highly satisfied the standards of American Heart Association. It is observed that, American Heart Association guidelines were met, when the designed unit is operated under a pressure of 6 bar or more for the range of chest stiffness from 6 to 6.5 N/mm. |
format |
Article |
author |
Rao, G. Babu Kumar, M. Wilson Sahu, Mona Rao, G. Anada Manoj Kumar, Nallapaneni |
author_facet |
Rao, G. Babu Kumar, M. Wilson Sahu, Mona Rao, G. Anada Manoj Kumar, Nallapaneni |
author_sort |
Rao, G. Babu |
title |
Usage of parallel manipulator for external chest compressions during cardiopulmonary resuscitation - an experimental study on feedback manikin |
title_short |
Usage of parallel manipulator for external chest compressions during cardiopulmonary resuscitation - an experimental study on feedback manikin |
title_full |
Usage of parallel manipulator for external chest compressions during cardiopulmonary resuscitation - an experimental study on feedback manikin |
title_fullStr |
Usage of parallel manipulator for external chest compressions during cardiopulmonary resuscitation - an experimental study on feedback manikin |
title_full_unstemmed |
Usage of parallel manipulator for external chest compressions during cardiopulmonary resuscitation - an experimental study on feedback manikin |
title_sort |
usage of parallel manipulator for external chest compressions during cardiopulmonary resuscitation - an experimental study on feedback manikin |
publisher |
IAEME Publication |
publishDate |
2018 |
url |
http://umpir.ump.edu.my/id/eprint/22598/1/Usage%20of%20parallel%20manipulator%20for%20external%20chest%20compressions%20during%20cardiopulmonary%20resuscitation.pdf http://umpir.ump.edu.my/id/eprint/22598/ https://www.iaeme.com/MasterAdmin/UploadFolder/IJMET_09_09_108/IJMET_09_09_108.pdf |
_version_ |
1643669425046421504 |