Hotspot detection for wall-mounted air-conditioner system

This paper presents the overall design of the hot spot detection and air flow control for a wall-mounted air-conditioner system. The system is designed to find out the hot areas that will cause the cool air from the air-conditioner not equally distributed to all areas in a room. Therefore, one of th...

Full description

Saved in:
Bibliographic Details
Main Authors: M. S., Jadin, Khai, Ng Boon, Norizam, Sulaiman, A. Salah, Wael
Format: Conference or Workshop Item
Language:English
Published: IEEE 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/24168/1/Hotspot%20detection%20for%20wall-mounted%20air-conditioner%20system.pdf
http://umpir.ump.edu.my/id/eprint/24168/
https://ieeexplore.ieee.org/abstract/document/8109050
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.24168
record_format eprints
spelling my.ump.umpir.241682019-10-10T03:42:11Z http://umpir.ump.edu.my/id/eprint/24168/ Hotspot detection for wall-mounted air-conditioner system M. S., Jadin Khai, Ng Boon Norizam, Sulaiman A. Salah, Wael TK Electrical engineering. Electronics Nuclear engineering This paper presents the overall design of the hot spot detection and air flow control for a wall-mounted air-conditioner system. The system is designed to find out the hot areas that will cause the cool air from the air-conditioner not equally distributed to all areas in a room. Therefore, one of the solutions is to control airflow of the air-conditioner so that the cool air could reach to that particular area for cooling purpose. As a result, it will increase the efficiency of the air-conditioner by cooling the hot areas (hotspot) instead of cooling the area that has already cooled. The random air swing in most conventional air-conditioner system does not help much in cooling the hotspot area, however, the proposed system is designed to cater that issue. The experiment has been done on the system by using the highest temperature method to detect the presence of human. The system can detect human based on the generated temperature array. For testing and data analysis, the user interface was developed using Matlab and the real application software was built on a smartphone using Android Studio software in order to control the airflow conveniently. IEEE 2017 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/24168/1/Hotspot%20detection%20for%20wall-mounted%20air-conditioner%20system.pdf M. S., Jadin and Khai, Ng Boon and Norizam, Sulaiman and A. Salah, Wael (2017) Hotspot detection for wall-mounted air-conditioner system. In: International Conference on Promising Electronic Technologies (ICPET 2017), 16-17 October 2017 , Deir El-Balah, Palestine. pp. 118-123.. ISBN 978-1-5386-2269-8 https://ieeexplore.ieee.org/abstract/document/8109050
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
M. S., Jadin
Khai, Ng Boon
Norizam, Sulaiman
A. Salah, Wael
Hotspot detection for wall-mounted air-conditioner system
description This paper presents the overall design of the hot spot detection and air flow control for a wall-mounted air-conditioner system. The system is designed to find out the hot areas that will cause the cool air from the air-conditioner not equally distributed to all areas in a room. Therefore, one of the solutions is to control airflow of the air-conditioner so that the cool air could reach to that particular area for cooling purpose. As a result, it will increase the efficiency of the air-conditioner by cooling the hot areas (hotspot) instead of cooling the area that has already cooled. The random air swing in most conventional air-conditioner system does not help much in cooling the hotspot area, however, the proposed system is designed to cater that issue. The experiment has been done on the system by using the highest temperature method to detect the presence of human. The system can detect human based on the generated temperature array. For testing and data analysis, the user interface was developed using Matlab and the real application software was built on a smartphone using Android Studio software in order to control the airflow conveniently.
format Conference or Workshop Item
author M. S., Jadin
Khai, Ng Boon
Norizam, Sulaiman
A. Salah, Wael
author_facet M. S., Jadin
Khai, Ng Boon
Norizam, Sulaiman
A. Salah, Wael
author_sort M. S., Jadin
title Hotspot detection for wall-mounted air-conditioner system
title_short Hotspot detection for wall-mounted air-conditioner system
title_full Hotspot detection for wall-mounted air-conditioner system
title_fullStr Hotspot detection for wall-mounted air-conditioner system
title_full_unstemmed Hotspot detection for wall-mounted air-conditioner system
title_sort hotspot detection for wall-mounted air-conditioner system
publisher IEEE
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/24168/1/Hotspot%20detection%20for%20wall-mounted%20air-conditioner%20system.pdf
http://umpir.ump.edu.my/id/eprint/24168/
https://ieeexplore.ieee.org/abstract/document/8109050
_version_ 1648741148539224064