Application of Ikaz and direct quadrature for solving leakage in pipeline distribution by using transmission line modelling
A new transient-based advance towards single leak detection is proposed which requires a measurement station with an end at the pipe system. The method use the frequency response and gives adequate results using low frequency bandwidth. This research apply Empirical Mode Decomposition (EMD) as the m...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
IOP Publishing
2019
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/24241/1/36.2%20Application%20of%20ikaz%20and%20direct%20quadrature.pdf http://umpir.ump.edu.my/id/eprint/24241/2/36.22%20Application%20of%20ikaz%20and%20direct%20quadrature.pdf http://umpir.ump.edu.my/id/eprint/24241/ https://iopscience.iop.org/article/10.1088/1757-899X/469/1/012081/pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English English |
id |
my.ump.umpir.24241 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.242412019-05-21T04:07:50Z http://umpir.ump.edu.my/id/eprint/24241/ Application of Ikaz and direct quadrature for solving leakage in pipeline distribution by using transmission line modelling Hanafi, M. Yusop M. F., Ghazali W. H., Azmi Mohd Fadhlan, Mohd Yusof M. A., PiRemli M. Z., Noordin TJ Mechanical engineering and machinery A new transient-based advance towards single leak detection is proposed which requires a measurement station with an end at the pipe system. The method use the frequency response and gives adequate results using low frequency bandwidth. This research apply Empirical Mode Decomposition (EMD) as the method denoising the noisy pressure transient signal before the signal further analyze using instantaneous frequency analysis. Therefore EMD is the way to decompose into Intrinsic Mode Function (IMF) from the signal. However it is difficult to select suitable IMF. Thus the paper proposed the implementation of Integrated Kurtosis-based algorithm Z-filter technique for that allows automatic selection of relevant and appropriates IMF. This work demonstrated the synthetic pressure transient signal generates using transmission line modelling (TLM) in order to test the effectiveness of Ikaz as the autonomous selection of IMF. This paper implement the Direct Quadrature as the instantaneous frequency analysis. A straight fluid network was designed using TLM fixing with higher resistance at some point act as a leak and connecting to the pipe feature (junction, pipefitting or blockage). The analysis results using Ikaz revealed that the method can be utilized as an automatic selection of intrinsic mode function (IMF) although the noise level ratio of the signal is lower. Ikaz-kurtosis ratio is recommended and advised to be implemented as automatic selection of intrinsic mode function (IMF) through DQ analysis. IOP Publishing 2019-01 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/24241/1/36.2%20Application%20of%20ikaz%20and%20direct%20quadrature.pdf pdf en http://umpir.ump.edu.my/id/eprint/24241/2/36.22%20Application%20of%20ikaz%20and%20direct%20quadrature.pdf Hanafi, M. Yusop and M. F., Ghazali and W. H., Azmi and Mohd Fadhlan, Mohd Yusof and M. A., PiRemli and M. Z., Noordin (2019) Application of Ikaz and direct quadrature for solving leakage in pipeline distribution by using transmission line modelling. In: 1st International Postgraduate Conference on Mechanical Engineering, IPCME 2018, 31 October 2018 , Universiti Malaysia Pahang, Pekan, Pahang. pp. 1-9., 469. ISSN 1757-8981 (Print); 1757-899X (Online) https://iopscience.iop.org/article/10.1088/1757-899X/469/1/012081/pdf |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Hanafi, M. Yusop M. F., Ghazali W. H., Azmi Mohd Fadhlan, Mohd Yusof M. A., PiRemli M. Z., Noordin Application of Ikaz and direct quadrature for solving leakage in pipeline distribution by using transmission line modelling |
description |
A new transient-based advance towards single leak detection is proposed which requires a measurement station with an end at the pipe system. The method use the frequency response and gives adequate results using low frequency bandwidth. This research apply Empirical Mode Decomposition (EMD) as the method denoising the noisy pressure transient signal before the signal further analyze using instantaneous frequency analysis. Therefore EMD is the way to decompose into Intrinsic Mode Function (IMF) from the signal. However it is difficult to select suitable IMF. Thus the paper proposed the implementation of Integrated Kurtosis-based algorithm Z-filter technique for that allows automatic selection of relevant and appropriates IMF. This work demonstrated the synthetic pressure transient signal generates using transmission line modelling (TLM) in order to test the effectiveness of Ikaz as the autonomous selection of IMF. This paper implement the Direct Quadrature as the instantaneous frequency analysis. A straight fluid network was designed using TLM fixing with higher resistance at some point act as a leak and connecting to the pipe feature (junction, pipefitting or blockage). The analysis results using Ikaz revealed that the method can be utilized as an automatic selection of intrinsic mode function (IMF) although the noise level ratio of the signal is lower. Ikaz-kurtosis ratio is recommended and advised to be implemented as automatic selection of intrinsic mode function (IMF) through DQ analysis. |
format |
Conference or Workshop Item |
author |
Hanafi, M. Yusop M. F., Ghazali W. H., Azmi Mohd Fadhlan, Mohd Yusof M. A., PiRemli M. Z., Noordin |
author_facet |
Hanafi, M. Yusop M. F., Ghazali W. H., Azmi Mohd Fadhlan, Mohd Yusof M. A., PiRemli M. Z., Noordin |
author_sort |
Hanafi, M. Yusop |
title |
Application of Ikaz and direct quadrature for solving leakage in pipeline distribution by using transmission line modelling |
title_short |
Application of Ikaz and direct quadrature for solving leakage in pipeline distribution by using transmission line modelling |
title_full |
Application of Ikaz and direct quadrature for solving leakage in pipeline distribution by using transmission line modelling |
title_fullStr |
Application of Ikaz and direct quadrature for solving leakage in pipeline distribution by using transmission line modelling |
title_full_unstemmed |
Application of Ikaz and direct quadrature for solving leakage in pipeline distribution by using transmission line modelling |
title_sort |
application of ikaz and direct quadrature for solving leakage in pipeline distribution by using transmission line modelling |
publisher |
IOP Publishing |
publishDate |
2019 |
url |
http://umpir.ump.edu.my/id/eprint/24241/1/36.2%20Application%20of%20ikaz%20and%20direct%20quadrature.pdf http://umpir.ump.edu.my/id/eprint/24241/2/36.22%20Application%20of%20ikaz%20and%20direct%20quadrature.pdf http://umpir.ump.edu.my/id/eprint/24241/ https://iopscience.iop.org/article/10.1088/1757-899X/469/1/012081/pdf |
_version_ |
1643669788783804416 |