Computational analysis on performance of thermal energy storage (TES) diffuser
Application of thermal energy storage (TES) system reduces cost and energy consumption. The performance of the overall operation is affected by diffuser design. In this study, computational analysis is used to determine the thermocline thickness. Three dimensional simulations with different tank hei...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IOP Publishing
2012
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/25143/1/Computational%20analysis%20on%20performance%20of%20thermal%20energy%20storage%20%28TES%29%20diffuser.pdf http://umpir.ump.edu.my/id/eprint/25143/ https://doi.org/10.1088/1757-899X/36/1/012015 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English |
id |
my.ump.umpir.25143 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.251432019-11-11T04:16:17Z http://umpir.ump.edu.my/id/eprint/25143/ Computational analysis on performance of thermal energy storage (TES) diffuser Mohd Azrul Hisham, Mohd Adib A. R., Ismail F., Adnan K., Kadirgama H. A., Salaam Zulkifli, Ahmad@Manap Nasrul Hadi, Johari Zulfika, Anuar N. S. N., Azmi TJ Mechanical engineering and machinery Application of thermal energy storage (TES) system reduces cost and energy consumption. The performance of the overall operation is affected by diffuser design. In this study, computational analysis is used to determine the thermocline thickness. Three dimensional simulations with different tank height-to-diameter ratio (HD), diffuser opening and the effect of difference number of diffuser holes are investigated. Medium HD tanks simulations with double ring octagonal diffuser show good thermocline behavior and clear distinction between warm and cold water. The result show, the best performance of thermocline thickness during 50% time charging occur in medium tank with height-to-diameter ratio of 4.0 and double ring octagonal diffuser with 48 holes (9mm opening ~ 60%) acceptable compared to diffuser with 6mm ~ 40% and 12mm ~ 80% opening. The conclusion is computational analysis method are very useful in the study on performance of thermal energy storage (TES). IOP Publishing 2012 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/25143/1/Computational%20analysis%20on%20performance%20of%20thermal%20energy%20storage%20%28TES%29%20diffuser.pdf Mohd Azrul Hisham, Mohd Adib and A. R., Ismail and F., Adnan and K., Kadirgama and H. A., Salaam and Zulkifli, Ahmad@Manap and Nasrul Hadi, Johari and Zulfika, Anuar and N. S. N., Azmi (2012) Computational analysis on performance of thermal energy storage (TES) diffuser. In: 1st International Conference on Mechanical Engineering Research, ICMER 2011, 5-7 Disember 2011 , Kuantan, Pahang Darul Makmur. pp. 1-6., 36 (012015). ISSN 1757-899X https://doi.org/10.1088/1757-899X/36/1/012015 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Mohd Azrul Hisham, Mohd Adib A. R., Ismail F., Adnan K., Kadirgama H. A., Salaam Zulkifli, Ahmad@Manap Nasrul Hadi, Johari Zulfika, Anuar N. S. N., Azmi Computational analysis on performance of thermal energy storage (TES) diffuser |
description |
Application of thermal energy storage (TES) system reduces cost and energy consumption. The performance of the overall operation is affected by diffuser design. In this study, computational analysis is used to determine the thermocline thickness. Three dimensional simulations with different tank height-to-diameter ratio (HD), diffuser opening and the effect of difference number of diffuser holes are investigated. Medium HD tanks simulations with double ring octagonal diffuser show good thermocline behavior and clear distinction between warm and cold water. The result show, the best performance of thermocline thickness during 50% time charging occur in medium tank with height-to-diameter ratio of 4.0 and double ring octagonal diffuser with 48 holes (9mm opening ~ 60%) acceptable compared to diffuser with 6mm ~ 40% and 12mm ~ 80% opening. The conclusion is computational analysis method are very useful in the study on performance of thermal energy storage (TES). |
format |
Conference or Workshop Item |
author |
Mohd Azrul Hisham, Mohd Adib A. R., Ismail F., Adnan K., Kadirgama H. A., Salaam Zulkifli, Ahmad@Manap Nasrul Hadi, Johari Zulfika, Anuar N. S. N., Azmi |
author_facet |
Mohd Azrul Hisham, Mohd Adib A. R., Ismail F., Adnan K., Kadirgama H. A., Salaam Zulkifli, Ahmad@Manap Nasrul Hadi, Johari Zulfika, Anuar N. S. N., Azmi |
author_sort |
Mohd Azrul Hisham, Mohd Adib |
title |
Computational analysis on performance of thermal energy storage (TES) diffuser |
title_short |
Computational analysis on performance of thermal energy storage (TES) diffuser |
title_full |
Computational analysis on performance of thermal energy storage (TES) diffuser |
title_fullStr |
Computational analysis on performance of thermal energy storage (TES) diffuser |
title_full_unstemmed |
Computational analysis on performance of thermal energy storage (TES) diffuser |
title_sort |
computational analysis on performance of thermal energy storage (tes) diffuser |
publisher |
IOP Publishing |
publishDate |
2012 |
url |
http://umpir.ump.edu.my/id/eprint/25143/1/Computational%20analysis%20on%20performance%20of%20thermal%20energy%20storage%20%28TES%29%20diffuser.pdf http://umpir.ump.edu.my/id/eprint/25143/ https://doi.org/10.1088/1757-899X/36/1/012015 |
_version_ |
1651866920107900928 |