Filter design for a nine level voltage source inverter for standalone power source
The rapid deflation of fossil reserves coupled with environmental pollution and degradation caused by direct and indirect crude oil-related activities has resulted in the need for a sustainable alternative and environmentally friendly means of energy generation. The quest triggers the upsurge of res...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2018
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/25487/1/25.1%20Filter%20design%20for%20a%20nine%20level%20voltage.pdf http://umpir.ump.edu.my/id/eprint/25487/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English |
id |
my.ump.umpir.25487 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.254872019-11-21T02:47:52Z http://umpir.ump.edu.my/id/eprint/25487/ Filter design for a nine level voltage source inverter for standalone power source Ibrahim, Haruna Nor Rul Hasma, Abdullah Aisha, Muhammad TK Electrical engineering. Electronics Nuclear engineering The rapid deflation of fossil reserves coupled with environmental pollution and degradation caused by direct and indirect crude oil-related activities has resulted in the need for a sustainable alternative and environmentally friendly means of energy generation. The quest triggers the upsurge of research in the field of Renewable energy sources and its conversion. Multilevel voltage converters serve as the main interface between the renewable energy source (solar, wind etc.) and the utility grid. The converter nonlinear nature results in the need for special modulation techniques and output filters that will minimise or eliminates the output harmonics to comply with the IEEE 519 standards. Therefore, this paper aims at assessing and comparing the harmonic content of a nine-level voltage source converter using four passive filters i.e. LC, LCL, LCL with series and parallel resistance. The output voltage and current waveforms, frequency spectrum and total harmonic distortion (THD) of all the filters are compared and analysed. It is found that all the filters have THD less than 5% with LCL with parallel resistor having the least THD content of 1.82%. The investigation is carried out via simulation using PSIM and Matlab software. 2018 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/25487/1/25.1%20Filter%20design%20for%20a%20nine%20level%20voltage.pdf Ibrahim, Haruna and Nor Rul Hasma, Abdullah and Aisha, Muhammad (2018) Filter design for a nine level voltage source inverter for standalone power source. In: National Seminar On Underwater System Technology 2018 (NUSYS’18), 26 - 27 September 2018 , Universiti Malaysia Pahang, Pekan. pp. 1-2.. (Unpublished) |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Ibrahim, Haruna Nor Rul Hasma, Abdullah Aisha, Muhammad Filter design for a nine level voltage source inverter for standalone power source |
description |
The rapid deflation of fossil reserves coupled with environmental pollution and degradation caused by direct and indirect crude oil-related activities has resulted in the need for a sustainable alternative and environmentally friendly means of energy generation. The quest triggers the upsurge of research in the field of Renewable energy sources and its conversion. Multilevel voltage converters serve as the main interface between the renewable energy source (solar, wind etc.) and the utility grid. The converter nonlinear nature results in the need for special modulation techniques and output filters that will minimise or eliminates the output harmonics to comply with the IEEE 519 standards. Therefore, this paper aims at assessing and comparing the harmonic content of a nine-level voltage source converter using four passive filters i.e. LC, LCL, LCL with series and parallel resistance. The output voltage and current waveforms, frequency spectrum and total harmonic distortion (THD) of all the filters are compared and analysed. It is found that all the filters have THD less than 5% with LCL with parallel resistor having the least THD content of 1.82%. The investigation is carried out via simulation using PSIM and Matlab software. |
format |
Conference or Workshop Item |
author |
Ibrahim, Haruna Nor Rul Hasma, Abdullah Aisha, Muhammad |
author_facet |
Ibrahim, Haruna Nor Rul Hasma, Abdullah Aisha, Muhammad |
author_sort |
Ibrahim, Haruna |
title |
Filter design for a nine level voltage source inverter for standalone power source |
title_short |
Filter design for a nine level voltage source inverter for standalone power source |
title_full |
Filter design for a nine level voltage source inverter for standalone power source |
title_fullStr |
Filter design for a nine level voltage source inverter for standalone power source |
title_full_unstemmed |
Filter design for a nine level voltage source inverter for standalone power source |
title_sort |
filter design for a nine level voltage source inverter for standalone power source |
publishDate |
2018 |
url |
http://umpir.ump.edu.my/id/eprint/25487/1/25.1%20Filter%20design%20for%20a%20nine%20level%20voltage.pdf http://umpir.ump.edu.my/id/eprint/25487/ |
_version_ |
1651866928926425088 |